167 related articles for article (PubMed ID: 30053260)
1. TOWARDS A PERSONALISED AND INTERACTIVE ASSESSMENT OF OCCUPATIONAL EXPOSURE TO MAGNETIC FIELD DURING DAILY ROUTINE IN MAGNETIC RESONANCE.
Hartwig V; Virgili G; Ferrante Vero LF; De Marchi D; Landini L; Giovannetti G
Radiat Prot Dosimetry; 2018 Dec; 182(4):546-554. PubMed ID: 30053260
[TBL] [Abstract][Full Text] [Related]
2. Exposure to static and time-varying magnetic fields from working in the static magnetic stray fields of MRI scanners: a comprehensive survey in the Netherlands.
Schaap K; Christopher-De Vries Y; Crozier S; De Vocht F; Kromhout H
Ann Occup Hyg; 2014 Nov; 58(9):1094-110. PubMed ID: 25139484
[TBL] [Abstract][Full Text] [Related]
3. MRI 'EXPOSIMETRY': HOW TO ANALYZE, COMPARE AND REPRESENT WORKER EXPOSURE TO STATIC MAGNETIC FIELD?
Delmas A; Weber N; Piffre J; Pasquier C; Felblinger J; Vuissoz PA
Radiat Prot Dosimetry; 2017 Dec; 177(4):415-423. PubMed ID: 28499015
[TBL] [Abstract][Full Text] [Related]
4. Health risk assessment of occupational exposure to a magnetic field from magnetic resonance imaging devices.
Karpowicz J; Gryz K
Int J Occup Saf Ergon; 2006; 12(2):155-67. PubMed ID: 16790173
[TBL] [Abstract][Full Text] [Related]
5. Analysis and measurements of magnetic field exposures for healthcare workers in selected MR environments.
Fuentes MA; Trakic A; Wilson SJ; Crozier S
IEEE Trans Biomed Eng; 2008 Apr; 55(4):1355-64. PubMed ID: 18390326
[TBL] [Abstract][Full Text] [Related]
6. Measurements of occupational exposure to switched gradient and spatially-varying magnetic fields in areas adjacent to 1.5 T clinical MRI systems.
Riches SF; Collins DJ; Charles-Edwards GD; Shafford JC; Cole J; Keevil SF; Leach MO
J Magn Reson Imaging; 2007 Nov; 26(5):1346-52. PubMed ID: 17969176
[TBL] [Abstract][Full Text] [Related]
7. [Experimental evaluation of the occupational exposure to static magnetic fields on a 3 T magnetic resonance scanner].
Moro L; Alabiso F; Parisoli F; Frigerio F
G Ital Med Lav Ergon; 2013; 35(1):26-31. PubMed ID: 23798231
[TBL] [Abstract][Full Text] [Related]
8. Exposure classification of MRI workers in epidemiological studies.
Hansson Mild K; Hand J; Hietanen M; Gowland P; Karpowicz J; Keevil S; Lagroye I; van Rongen E; Scarfi MR; Wilén J
Bioelectromagnetics; 2013 Jan; 34(1):81-4. PubMed ID: 22532229
[TBL] [Abstract][Full Text] [Related]
9. Retrospective assessment of exposure to static magnetic fields during production and development of magnetic resonance imaging systems.
Bongers S; Christopher Y; Engels H; Slottje P; Kromhout H
Ann Occup Hyg; 2014 Jan; 58(1):85-102. PubMed ID: 24081380
[TBL] [Abstract][Full Text] [Related]
10. The Procedure for Quantitative Characterization and Analysis of Magnetic Fields in Magnetic Resonance Sites for Protection of Workers: A Pilot Study.
Hartwig V; Biagini C; De Marchi D; Flori A; Gabellieri C; Virgili G; Ferrante Vero LF; Landini L; Vanello N; Giovannetti G
Ann Work Expo Health; 2019 Mar; 63(3):328-336. PubMed ID: 30852618
[TBL] [Abstract][Full Text] [Related]
11. ASSESSMENT OF MOVEMENT-INDUCED TIME-VARYING MAGNETIC FIELDS EXPOSURE IN MAGNETIC RESONANCE IMAGING BY A COMMERCIAL PORTABLE MAGNETOMETER.
Filice S; Rossi R; Crisi G
Radiat Prot Dosimetry; 2019 Dec; 185(3):326-330. PubMed ID: 30806458
[TBL] [Abstract][Full Text] [Related]
12. Numerical field evaluation of healthcare workers when bending towards high-field MRI magnets.
Wang H; Trakic A; Liu F; Crozier S
Magn Reson Med; 2008 Feb; 59(2):410-22. PubMed ID: 18228572
[TBL] [Abstract][Full Text] [Related]
13. Assessment of occupational exposure to radiofrequency fields and radiation.
Cooper TG; Allen SG; Blackwell RP; Litchfield I; Mann SM; Pope JM; van Tongeren MJ
Radiat Prot Dosimetry; 2004; 111(2):191-203. PubMed ID: 15266067
[TBL] [Abstract][Full Text] [Related]
14. A novel tool for estimation of magnetic resonance occupational exposure to spatially varying magnetic fields.
Hartwig V; Vanello N; Giovannetti G; Lombardi M; Landini L; Santarelli MF
MAGMA; 2011 Dec; 24(6):323-30. PubMed ID: 21892733
[TBL] [Abstract][Full Text] [Related]
15. Personal exposure to static and time-varying magnetic fields during MRI system test procedures.
de Vocht F; Muller F; Engels H; Kromhout H
J Magn Reson Imaging; 2009 Nov; 30(5):1223-8. PubMed ID: 19856458
[TBL] [Abstract][Full Text] [Related]
16. [Exposure to static magnetic field and health hazards during the operation of magnetic resonance scanners].
Karpowicz J; Gryz K; Politański P; Zmyślony M
Med Pr; 2011; 62(3):309-21. PubMed ID: 21870421
[TBL] [Abstract][Full Text] [Related]
17. [Health effects of occupational exposure to static magnetic fields used in magnetic resonance imaging: a review].
Franco G; Perduri R; Murolo A
Med Lav; 2008; 99(1):16-28. PubMed ID: 18254536
[TBL] [Abstract][Full Text] [Related]
18. Numerical study of currents in workers induced by body-motion around high-ultrahigh field MRI magnets.
; Trakic A; Wang H; Liu F
J Magn Reson Imaging; 2007 Nov; 26(5):1261-77. PubMed ID: 17969138
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of exposure to (ultra) high static magnetic fields during activities around human MRI scanners.
Fatahi M; Karpowicz J; Gryz K; Fattahi A; Rose G; Speck O
MAGMA; 2017 Jun; 30(3):255-264. PubMed ID: 27981395
[TBL] [Abstract][Full Text] [Related]
20. Work-related factors associated with occupational exposure to static magnetic stray fields from MRI scanners.
Schaap K; Christopher-De Vries Y; Cambron-Goulet É; Kromhout H
Magn Reson Med; 2016 May; 75(5):2141-55. PubMed ID: 26096360
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]