148 related articles for article (PubMed ID: 30055300)
1. Transfemoral transcatheter valve-in-valve implantation for the treatment of a degenerated tricuspid valve bioprosthesis.
Voudris V; Kosmas E; Balanika M; Tsiapras D; Iakovou I
Hellenic J Cardiol; 2019; 60(3):198-201. PubMed ID: 30055300
[No Abstract] [Full Text] [Related]
2. Transfemoral access for valve in valve implantation of an Edwards Sapien XT valve in a stenotic tricuspid bioprosthesis under fluoroscopic guidance.
Greif M; Schramm R; Steinbeck G; Hagl C; Schmitz C; Kupatt C
Can J Cardiol; 2013 Aug; 29(8):1014.e3-4. PubMed ID: 23406738
[TBL] [Abstract][Full Text] [Related]
3. Transcatheter Tricuspid Valve-in-Valve Replacement with an Edwards Sapien 3 Valve.
Loyalka P; Nascimbene A; Metz B; Gregoric ID; Raman AS; Kar B
Tex Heart Inst J; 2017 Jun; 44(3):209-213. PubMed ID: 28761403
[TBL] [Abstract][Full Text] [Related]
4. Troubleshooting in transatrial tricuspid valve-in-valve implantation.
Cocchieri R; Wiegerinck EM; de Groot JR; Bouma BJ; Marsman M; de Mol BA; Baan J
Ann Thorac Surg; 2012 Oct; 94(4):1349-52. PubMed ID: 23006698
[TBL] [Abstract][Full Text] [Related]
5. Edwards valve-in-valve implantation in tricuspid position.
Álvarez-Fuente M; Haas NA; Del Cerro MJ
Cardiol Young; 2017 Oct; 27(8):1633-1636. PubMed ID: 28506330
[TBL] [Abstract][Full Text] [Related]
6. Transfemoral implantation of an Edwards SAPIEN valve in a tricuspid bioprosthesis without fluoroscopic landmarks.
Calvert PA; Himbert D; Brochet E; Radu C; Iung B; Hvass U; Darondel JM; Depoix JP; Nataf P; Vahanian A
EuroIntervention; 2012 Mar; 7(11):1336-9. PubMed ID: 21959750
[TBL] [Abstract][Full Text] [Related]
7. Failed Percutaneous Transcatheter Tricuspid Valve-in-Valve Replacement Caused by Retained Valve Holder.
Bennett JM; Deegan R; Maltais S; Pretorius M
Anesth Analg; 2016 Jan; 122(1):34-6. PubMed ID: 26678467
[No Abstract] [Full Text] [Related]
8. Transcatheter Tricuspid Valve-in-Valve Replacement With Subsequent Bioprosthetic Valve Fracture to Optimize Hemodynamic Function.
Hensey M; Alenezi AR; Murdoch DJ; Sathananthan J; Weir-McCall JR; Wood D; Blanke P; Webb J
JACC Cardiovasc Interv; 2018 Nov; 11(21):2226-2227. PubMed ID: 30343018
[No Abstract] [Full Text] [Related]
9. Transcatheter tricuspid valve implantation: a multicentre French study.
Godart F; Baruteau AE; Petit J; Riou JY; Sassolas F; Lusson JR; Fraisse A; Boudjemline Y
Arch Cardiovasc Dis; 2014 Nov; 107(11):583-91. PubMed ID: 25282331
[TBL] [Abstract][Full Text] [Related]
10. Cracking a tricuspid perimount bioprosthesis to optimize a second transcatheter sapien valve-in-valve placement.
Brown SC; Cools B; Gewillig M
Catheter Cardiovasc Interv; 2016 Sep; 88(3):456-9. PubMed ID: 27015096
[TBL] [Abstract][Full Text] [Related]
11. Transcatheter Sapien valve implantation in a native tricuspid valve after failed surgical repair.
Kefer J; Sluysmans T; Vanoverschelde JL
Catheter Cardiovasc Interv; 2014 Apr; 83(5):841-5. PubMed ID: 24339249
[TBL] [Abstract][Full Text] [Related]
12. Valve-in-Valve Procedures in Failing Biological Xenografts Using a Novel Balloon-Expandable Device: Experience in Aortic, Mitral, and Tricuspid Positions.
Schaefer A; Conradi L; Seiffert M; Lubos E; Blankenberg S; Reichenspurner H; Schaefer U; Treede H
Thorac Cardiovasc Surg; 2016 Aug; 64(5):366-73. PubMed ID: 26277078
[TBL] [Abstract][Full Text] [Related]
13. Transcatheter Tricuspid Valve-in-Valve Replacement Via Right Internal Jugular Vein Access in a 39-Year-Old Woman.
Parikh PB; Pyo R; Stergiopoulos K; Katz J; Fan R; Izrailtyan I; Bilfinger T
J Invasive Cardiol; 2019 Oct; 31(10):E304-E305. PubMed ID: 31567122
[TBL] [Abstract][Full Text] [Related]
14. Valve-in-valve in the tricuspid position for a stenosed bioprosthesis.
Beckerman Z; Cohen O; Agmon Y; Bolotin G
Heart Surg Forum; 2013 Apr; 16(2):E96-8. PubMed ID: 23625484
[TBL] [Abstract][Full Text] [Related]
15. Is Transcatheter Tricuspid Valve-In-Valve Implantation Feasible in the Presence of Right Atrial Thrombus?
Henzel J; Dzielińska Z; Konka M; Dąbrowski M; Protasiewicz M; Witkowski A; Demkow M
J Heart Valve Dis; 2017 Mar; 26(2):211-214. PubMed ID: 28820553
[TBL] [Abstract][Full Text] [Related]
16. Percutaneous Transcatheter Treatment for Tricuspid Bioprosthesis Failure.
Ruparelia N; Mangieri A; Ancona M; Giannini F; Agricola E; Montorfano M; De Bonis M; Alfieri O; Colombo A; Latib A
Catheter Cardiovasc Interv; 2016 Nov; 88(6):994-1001. PubMed ID: 27184831
[TBL] [Abstract][Full Text] [Related]
17. Successful valve-in-valve transcatheter intervention to treat severe stenosis of a 38-year-old tricuspid bioprosthesis.
John A; Onwordi EC; Richens T; Shah BN
Echocardiography; 2024 Apr; 41(4):e15804. PubMed ID: 38578295
[TBL] [Abstract][Full Text] [Related]
18. Jailing of a Pacemaker Lead During Tricuspid Valve-in-Valve Implantation With an Edwards SAPIEN XT Transcatheter Heart Valve.
Paradis JM; Bernier M; Houde C; Dumont É; Doyle D; Mohammadi S; DeLarochellière R; Philippon F; Rodés-Cabau J
Can J Cardiol; 2015 Jun; 31(6):819.e9-11. PubMed ID: 25935882
[No Abstract] [Full Text] [Related]
19. Direct transatrial transcatheter SAPIEN valve implantation through right minithoracotomy in a degenerated mitral bioprosthetic valve.
Bruschi G; Barosi A; Colombo P; Botta L; Oreglia J; De Marco F; Paino R; Klugmann S; Martinelli L
Ann Thorac Surg; 2012 May; 93(5):1708-10. PubMed ID: 22541204
[TBL] [Abstract][Full Text] [Related]
20. How should I treat prosthetic tricuspid stenosis in an extreme surgical risk patient?
Lilly SM; Rome J; Anwaruddin S; Shreenivas S; Desai N; Silvestry FE; Herrmann HC; Fassa A; Himbert D; Brochet E; Labbé JP; Depoix JP; Hvass U; Vahanian A; Holoshitz N; Kenny D; Hijazi ZM
EuroIntervention; 2013 Jul; 9(3):407-9. PubMed ID: 23872655
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]