These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
125 related articles for article (PubMed ID: 30058529)
1. Periprosthetic stress fracture around a well-fixed type 2B short uncemented stem. Slullitel PA; Oñativia JI; Llano L; Comba F; Zanotti G; Piccaluga F; Buttaro MA SICOT J; 2018; 4():33. PubMed ID: 30058529 [TBL] [Abstract][Full Text] [Related]
2. [Periprosthetic Femoral Fractures after Total Hip Replacement: Our Results and Treatment Complications]. Pavelka T; Salášek M; Weisová D Acta Chir Orthop Traumatol Cech; 2017; 84(1):52-58. PubMed ID: 28253947 [TBL] [Abstract][Full Text] [Related]
3. Increased risk of periprosthetic femur fractures associated with a unique cementless stem design. Watts CD; Abdel MP; Lewallen DG; Berry DJ; Hanssen AD Clin Orthop Relat Res; 2015 Jun; 473(6):2045-53. PubMed ID: 25502478 [TBL] [Abstract][Full Text] [Related]
4. Thigh pain, subsidence and survival using a short cementless femoral stem with pure metaphyseal fixation at minimum 9-year follow-up. Cinotti G; Della Rocca A; Sessa P; Ripani FR; Giannicola G Orthop Traumatol Surg Res; 2013 Feb; 99(1):30-6. PubMed ID: 23260613 [TBL] [Abstract][Full Text] [Related]
5. Long-Term Outcomes of Ultra-Short Metaphyseal-Fitting Anatomic Cementless Femoral Stem in Total Hip Arthroplasty With Ceramic-on-Ceramic Articulation for Young Patients. Kim YH; Park JW J Arthroplasty; 2019 Oct; 34(10):2427-2433. PubMed ID: 31200989 [TBL] [Abstract][Full Text] [Related]
6. Long-term results of an anatomically implanted hip arthroplasty with a short stem prosthesis (MiniHip von Engelhardt LV; Breil-Wirth A; Kothny C; Seeger JB; Grasselli C; Jerosch J World J Orthop; 2018 Oct; 9(10):210-219. PubMed ID: 30364820 [TBL] [Abstract][Full Text] [Related]
7. Epidemiology of periprosthetic femoral fractures in 5417 revision total hip arthroplasties: a 40-year experience. Abdel MP; Houdek MT; Watts CD; Lewallen DG; Berry DJ Bone Joint J; 2016 Apr; 98-B(4):468-74. PubMed ID: 27037428 [TBL] [Abstract][Full Text] [Related]
8. A calcar collar is protective against early periprosthetic femoral fracture around cementless femoral components in primary total hip arthroplasty: a registry study with biomechanical validation. Lamb JN; Baetz J; Messer-Hannemann P; Adekanmbi I; van Duren BH; Redmond A; West RM; Morlock MM; Pandit HG Bone Joint J; 2019 Jul; 101-B(7):779-786. PubMed ID: 31256663 [TBL] [Abstract][Full Text] [Related]
9. Clinical outcome and quantitative evaluation of periprosthetic bone-remodeling of an uncemented femoral component with taper design. A prospective study. Pitto RP; Schramm M; Hohmann D; Schmidt R Chir Organi Mov; 2001; 86(2):87-97. PubMed ID: 12025051 [TBL] [Abstract][Full Text] [Related]
10. A comparison of a conventional versus a short, anatomical metaphyseal-fitting cementless femoral stem in the treatment of patients with a fracture of the femoral neck. Kim YH; Oh JH J Bone Joint Surg Br; 2012 Jun; 94(6):774-81. PubMed ID: 22628591 [TBL] [Abstract][Full Text] [Related]
11. Is a short stem suitable for patients with hip dysplasia? A report on technical problems encountered during femoral reconstruction. Buttaro MA; Slullitel PA; Zanotti G; Comba FM; Piccaluga F Hip Int; 2018 May; 28(3):315-323. PubMed ID: 29048691 [TBL] [Abstract][Full Text] [Related]
12. Fourth-generation ceramic-on-ceramic total hip arthroplasty in patients of 55 years or younger: short-term results and complications analysis. Wang W; Guo W; Yue D; Shi Z; Zhang N; Liu Z; Sun W; Wang B; Li Z Chin Med J (Engl); 2014; 127(12):2310-5. PubMed ID: 24931248 [TBL] [Abstract][Full Text] [Related]
13. Infection in periprosthetic hip fractures. Cabral R Hip Int; 2012; 22 Suppl 8():S79-82. PubMed ID: 22956376 [TBL] [Abstract][Full Text] [Related]
14. Hydroxyapatite-coated stems with metaphyseal and diaphyseal press-fit. Eleven-year follow-up results. Hernández Cortés P; Nájera Sagastume OO; Mesa Ramos F; Pajares López M; Hernández Hernández MA Acta Orthop Belg; 2002 Feb; 68(1):24-32. PubMed ID: 11915455 [TBL] [Abstract][Full Text] [Related]
15. Higher periprosthetic fracture rate associated with use of modern uncemented stems compared to cemented stems in femoral neck fractures. Song JSA; Dillman D; Wilson D; Dunbar M; Richardson G Hip Int; 2019 Mar; 29(2):177-183. PubMed ID: 29682992 [TBL] [Abstract][Full Text] [Related]
16. [S-ROM Modular THR System -Three and Half Years of Experience.]. Bartonícek J; Lunácek L; Fric V Acta Chir Orthop Traumatol Cech; 2000; 67(6):372-81. PubMed ID: 20478232 [TBL] [Abstract][Full Text] [Related]
17. Uncemented extensive porous titanium-coated long femoral stem prostheses are effective in treatment of Vancouver type B2 periprosthetic femoral fractures: A retrospective mid- to long-term follow-up study. Wang Q; Li D; Kang P J Orthop Surg (Hong Kong); 2019; 27(2):2309499019857653. PubMed ID: 31232172 [TBL] [Abstract][Full Text] [Related]
18. High incidence of stem loosening in association with periprosthetic femur fractures in previously well-fixed cementless grit-blasted tapered-wedge stems. Lim SJ; Lee KJ; Min BW; Song JH; So SY; Park YS Int Orthop; 2015 Sep; 39(9):1689-93. PubMed ID: 25385003 [TBL] [Abstract][Full Text] [Related]
19. Nonunion after periprosthetic femoral fracture associated with total hip arthroplasty. Crockarell JR; Berry DJ; Lewallen DG J Bone Joint Surg Am; 1999 Aug; 81(8):1073-9. PubMed ID: 10466640 [TBL] [Abstract][Full Text] [Related]
20. Fracture of Uncemented Revision Femoral Stems in three Arthroplasty Patients: A Case Series with three different brands. Merchant R; Kelly I; Quinlan J J Orthop Case Rep; 2014; 4(4):12-5. PubMed ID: 27298992 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]