129 related articles for article (PubMed ID: 30059830)
1. Exit-wave phase retrieval from a single high-resolution transmission electron microscopy image of a weak-phase object.
Lin F; Ren XB; Zhou WP; Zhang LY; Xiao Y; Zhang Q; Xu HT; Li H; Jin CH
Micron; 2018 Nov; 114():23-31. PubMed ID: 30059830
[TBL] [Abstract][Full Text] [Related]
2. Effects of non-rotationally symmetric aberrations on the quantitative measurement of lattice positions in a graphene monolayer using high-resolution transmission electron microscopy.
Lin F; Jian J; Ye L; Jin C
Microscopy (Oxf); 2015 Oct; 64(5):311-8. PubMed ID: 26070475
[TBL] [Abstract][Full Text] [Related]
3. Exit wave reconstruction of a focal series of images with structural changes in high-resolution transmission electron microscopy.
Zhang X; Chen S; Wang S; Huang Y; Jin C; Lin F
J Microsc; 2024 May; ():. PubMed ID: 38819026
[TBL] [Abstract][Full Text] [Related]
4. Simulation of bonding effects in HRTEM images of light element materials.
Kurasch S; Meyer JC; Künzel D; Groß A; Kaiser U
Beilstein J Nanotechnol; 2011; 2():394-404. PubMed ID: 22003447
[TBL] [Abstract][Full Text] [Related]
5. A review of sample thickness effects on high-resolution transmission electron microscopy imaging.
Li S; Chang Y; Wang Y; Xu Q; Ge B
Micron; 2020 Mar; 130():102813. PubMed ID: 31927411
[TBL] [Abstract][Full Text] [Related]
6. Automated phase retrieval of a single-material object using a single out-of-focus image.
Eastwood SA; Paganin DM; Liu AC
Opt Lett; 2011 May; 36(10):1878-80. PubMed ID: 21593921
[TBL] [Abstract][Full Text] [Related]
7. Thickness and rotational effects in simulated HRTEM images of graphene on hexagonal boron nitride.
Green AJ; Diebold AC
Microsc Microanal; 2014 Dec; 20(6):1753-63. PubMed ID: 25222467
[TBL] [Abstract][Full Text] [Related]
8. Linear versus non-linear structural information limit in high-resolution transmission electron microscopy.
Van Aert S; Chen JH; Van Dyck D
Ultramicroscopy; 2010 Oct; 110(11):1404-10. PubMed ID: 20655146
[TBL] [Abstract][Full Text] [Related]
9. Reconstructing the exit wave of 2D materials in high-resolution transmission electron microscopy using machine learning.
Leth Larsen MH; Dahl F; Hansen LP; Barton B; Kisielowski C; Helveg S; Winther O; Hansen TW; Schiøtz J
Ultramicroscopy; 2023 Jan; 243():113641. PubMed ID: 36401890
[TBL] [Abstract][Full Text] [Related]
10. An improved Wiener deconvolution filter for high-resolution electron microscopy images.
Lin F; Jin C
Micron; 2013 Jul; 50():1-6. PubMed ID: 23628497
[TBL] [Abstract][Full Text] [Related]
11. Facing the phase problem in Coherent Diffractive Imaging via Memetic Algorithms.
Colombo A; Galli DE; De Caro L; Scattarella F; Carlino E
Sci Rep; 2017 Feb; 7():42236. PubMed ID: 28181592
[TBL] [Abstract][Full Text] [Related]
12. Object wave reconstruction by phase-plate transmission electron microscopy.
Gamm B; Dries M; Schultheiss K; Blank H; Rosenauer A; Schröder RR; Gerthsen D
Ultramicroscopy; 2010 Jun; 110(7):807-14. PubMed ID: 20189718
[TBL] [Abstract][Full Text] [Related]
13. Automatic software correction of residual aberrations in reconstructed HRTEM exit waves of crystalline samples.
Ophus C; Rasool HI; Linck M; Zettl A; Ciston J
Adv Struct Chem Imaging; 2017; 2(1):15. PubMed ID: 28003952
[TBL] [Abstract][Full Text] [Related]
14. Atomic imaging in aberration-corrected high-resolution transmission electron microscopy.
Chen JH; Zandbergen HW; Dyck DV
Ultramicroscopy; 2004 Jan; 98(2-4):81-97. PubMed ID: 15046789
[TBL] [Abstract][Full Text] [Related]
15. Simulation study of aberration-corrected high-resolution transmission electron microscopy imaging of few-layer-graphene stacking.
Nelson F; Diebold AC; Hull R
Microsc Microanal; 2010 Apr; 16(2):194-9. PubMed ID: 20100382
[TBL] [Abstract][Full Text] [Related]
16. The wrap-around problem and optimal padding in the exit wave reconstruction using HRTEM images.
Lin F; Chen FR; Chen Q; Tang D; Peng LM
J Electron Microsc (Tokyo); 2006 Aug; 55(4):191-200. PubMed ID: 17050589
[TBL] [Abstract][Full Text] [Related]
17. When to use the projection assumption and the weak-phase object approximation in phase contrast cryo-EM.
Vulović M; Voortman LM; van Vliet LJ; Rieger B
Ultramicroscopy; 2014 Jan; 136():61-6. PubMed ID: 24012936
[TBL] [Abstract][Full Text] [Related]
18. Contrast Transfer Function-Based Exit-Wave Reconstruction and Denoising of Atomic-Resolution Transmission Electron Microscopy Images of Graphene and Cu Single Atom Substitutions by Deep Learning Framework.
Lee J; Lee Y; Kim J; Lee Z
Nanomaterials (Basel); 2020 Oct; 10(10):. PubMed ID: 33036252
[TBL] [Abstract][Full Text] [Related]
19. Compositional analysis of mixed-cation-anion III-V semiconductor interfaces using phase retrieval high-resolution transmission electron microscopy.
Mahalingam K; Eyink KG; Brown GJ; Dorsey DL; Kisielowski CF; Thust A
J Microsc; 2008 Jun; 230(Pt 3):372-81. PubMed ID: 18503662
[TBL] [Abstract][Full Text] [Related]
20. Domino phase-retrieval algorithm for structure determination using electron diffraction and high-resolution transmission electron microscopy patterns.
Chukhovskii FN; Poliakov AM
Acta Crystallogr A; 2003 Jan; 59(Pt 1):48-53. PubMed ID: 12496462
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]