  • 1. The impact of a radiologist-led workshop on MRI target volume delineation for radiotherapy.
    Kumar S; Holloway L; Roach D; Pogson E; Veera J; Batumalai V; Lim K; Delaney GP; Lazarus E; Borok N; Moses D; Jameson MG; Vinod S
    J Med Radiat Sci; 2018 Dec; 65(4):300-310. PubMed ID: 30076690
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Variability of gross tumour volume delineation: MRI and CT based tumour and lymph node delineation for lung radiotherapy.
    Kumar S; Holloway L; Boxer M; Yap ML; Chlap P; Moses D; Vinod S
    Radiother Oncol; 2022 Feb; 167():292-299. PubMed ID: 34896156
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Inter-observer variations of the tumor bed delineation for patients after breast conserving surgery in preoperative magnetic resonance and computed tomography scan fusion.
    Jiang J; Chen J; Li W; Li Y; Chen Y; Zhang Z; Liu C; Han D; Sun H; Li B; Huang W
    BMC Cancer; 2021 Jul; 21(1):838. PubMed ID: 34284752
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of Magnetic Resonance Imaging and Computed Tomography for Breast Target Volume Delineation in Prone and Supine Positions.
    Pogson EM; Delaney GP; Ahern V; Boxer MM; Chan C; David S; Dimigen M; Harvey JA; Koh ES; Lim K; Papadatos G; Yap ML; Batumalai V; Lazarus E; Dundas K; Shafiq J; Liney G; Moran C; Metcalfe P; Holloway L
    Int J Radiat Oncol Biol Phys; 2016 Nov; 96(4):905-912. PubMed ID: 27788960
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Inter-observer variability in target delineation increases during adaptive treatment of head-and-neck and lung cancer.
    Apolle R; Appold S; Bijl HP; Blanchard P; Bussink J; Faivre-Finn C; Khalifa J; Laprie A; Lievens Y; Madani I; Ruffier A; de Ruysscher D; van Elmpt W; Troost EGC
    Acta Oncol; 2019 Oct; 58(10):1378-1385. PubMed ID: 31271079
    [No Abstract]   [Full Text] [Related]  

  • 6. Magnetic resonance imaging organ at risk delineation for nasopharyngeal radiotherapy: Measuring the effectiveness of an educational intervention.
    Ryan O; Dundas K; Surjan Y; Elwadia D; Nguyen K; Cardoso M; Kumar S
    J Med Radiat Sci; 2023 Apr; 70 Suppl 2(Suppl 2):59-69. PubMed ID: 36751021
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reducing the dose of gadolinium-based contrast agents for DCE-MRI guided SBRT: The effects on inter and intra observer variability for preoperative target volume delineation in early stage breast cancer patients.
    Mouawad M; Biernaski H; Brackstone M; Lock M; Yaremko B; Sexton T; Yu E; Dinniwell RE; Lynn K; Hajdok G; Prato FS; Thompson RT; Gelman N; Gaede S
    Radiother Oncol; 2019 Feb; 131():60-65. PubMed ID: 30773188
    [TBL] [Abstract][Full Text] [Related]  

  • 8. MRI and CT imaging for preoperative target volume delineation in breast-conserving therapy.
    den Hartogh MD; Philippens ME; van Dam IE; Kleynen CE; Tersteeg RJ; Pijnappel RM; Kotte AN; Verkooijen HM; van den Bosch MA; van Vulpen M; van Asselen B; van den Bongard HD
    Radiat Oncol; 2014 Feb; 9():63. PubMed ID: 24571783
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluating diffusion-weighted magnetic resonance imaging for target volume delineation in head and neck radiotherapy.
    Cardoso M; Min M; Jameson M; Tang S; Rumley C; Fowler A; Estall V; Pogson E; Holloway L; Forstner D
    J Med Imaging Radiat Oncol; 2019 Jun; 63(3):399-407. PubMed ID: 30816646
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dedicated MRI simulation for cervical cancer radiation treatment planning: Assessing the impact on clinical target volume delineation.
    Veera J; Lim K; Dowling JA; O'Connor C; Holloway LC; Vinod SK
    J Med Imaging Radiat Oncol; 2019 Apr; 63(2):236-243. PubMed ID: 30506944
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Chest Magnetic Resonance Imaging Decreases Inter-observer Variability of Gross Target Volume for Lung Tumors.
    Basson L; Jarraya H; Escande A; Cordoba A; Daghistani R; Pasquier D; Lacornerie T; Lartigau E; Mirabel X
    Front Oncol; 2019; 9():690. PubMed ID: 31456936
    [No Abstract]   [Full Text] [Related]  

  • 12. Volume Delineation in Cervical Cancer With T2 and Diffusion-weighted MRI: Agreement on Volumes Between Observers.
    Rosa C; Pizzi AD; Augurio A; Caravatta L; DI Tommaso M; Mincuzzi E; Cinalli S; Basilico R; Porreca A; DI Nicola M; Genovesi D
    In Vivo; 2020; 34(4):1981-1986. PubMed ID: 32606170
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of Multisource Adaptive MRI Fusion for Gross Tumor Volume Delineation of Hepatocellular Carcinoma.
    Cheung AL; Zhang L; Liu C; Li T; Cheung AH; Leung C; Leung AK; Lam SK; Lee VH; Cai J
    Front Oncol; 2022; 12():816678. PubMed ID: 35280780
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Inter-scan and inter-observer tumour volume delineation variability on cone beam computed tomography in patients treated with stereotactic body radiation therapy for early-stage non-small cell lung cancer.
    Hou Y; Lee S; Agrawal V; Romano J; Baldini EH; Chen AB; Kozono DE; Killoran JH; Wagar M; Hacker FL; Aerts HJ; Lewis JH; Mak RH
    J Med Imaging Radiat Oncol; 2017 Feb; 61(1):93-98. PubMed ID: 27709803
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The contribution of integrated PET/CT to the evolving definition of treatment volumes in radiation treatment planning in lung cancer.
    Ashamalla H; Rafla S; Parikh K; Mokhtar B; Goswami G; Kambam S; Abdel-Dayem H; Guirguis A; Ross P; Evola A
    Int J Radiat Oncol Biol Phys; 2005 Nov; 63(4):1016-23. PubMed ID: 15979817
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Variability of Gross Tumor Volume Delineation for Stereotactic Body Radiotherapy of the Lung With Tri-
    Wee CW; An HJ; Kang HC; Kim HJ; Wu HG
    Technol Cancer Res Treat; 2018 Jan; 17():1533033818787383. PubMed ID: 30012039
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Magnetic resonance imaging for prostate bed radiotherapy planning: An inter- and intra-observer variability study.
    Barkati M; Simard D; Taussky D; Delouya G
    J Med Imaging Radiat Oncol; 2016 Apr; 60(2):255-9. PubMed ID: 26568515
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Conformal radiotherapy for lung cancer: different delineation of the gross tumor volume (GTV) by radiologists and radiation oncologists.
    Giraud P; Elles S; Helfre S; De Rycke Y; Servois V; Carette MF; Alzieu C; Bondiau PY; Dubray B; Touboul E; Housset M; Rosenwald JC; Cosset JM
    Radiother Oncol; 2002 Jan; 62(1):27-36. PubMed ID: 11830310
    [TBL] [Abstract][Full Text] [Related]  

  • 19. PET/MRI-guided GTV delineation during radiotherapy planning in patients with squamous cell carcinoma of the tongue.
    Samołyk-Kogaczewska N; Sierko E; Zuzda K; Gugnacki P; Szumowski P; Mojsak M; Burzyńska-Śliwowska J; Wojtukiewicz MZ; Szczecina K; Jurgilewicz DH
    Strahlenther Onkol; 2019 Sep; 195(9):780-791. PubMed ID: 31214735
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Uncertainties of target volume delineation in MRI guided adaptive brachytherapy of cervix cancer: a multi-institutional study.
    Petrič P; Hudej R; Rogelj P; Blas M; Tanderup K; Fidarova E; Kirisits C; Berger D; Dimopoulos JC; Pötter R; Hellebust TP
    Radiother Oncol; 2013 Apr; 107(1):6-12. PubMed ID: 23453539
    [TBL] [Abstract][Full Text] [Related]  