560 related articles for article (PubMed ID: 30081927)
1. PCA and deep learning based myoelectric grasping control of a prosthetic hand.
Li C; Ren J; Huang H; Wang B; Zhu Y; Hu H
Biomed Eng Online; 2018 Aug; 17(1):107. PubMed ID: 30081927
[TBL] [Abstract][Full Text] [Related]
2. Deep learning-based artificial vision for grasp classification in myoelectric hands.
Ghazaei G; Alameer A; Degenaar P; Morgan G; Nazarpour K
J Neural Eng; 2017 Jun; 14(3):036025. PubMed ID: 28467317
[TBL] [Abstract][Full Text] [Related]
3. Closed-loop control of grasping with a myoelectric hand prosthesis: which are the relevant feedback variables for force control?
Ninu A; Dosen S; Muceli S; Rattay F; Dietl H; Farina D
IEEE Trans Neural Syst Rehabil Eng; 2014 Sep; 22(5):1041-52. PubMed ID: 24801625
[TBL] [Abstract][Full Text] [Related]
4. Decoding the grasping intention from electromyography during reaching motions.
Batzianoulis I; Krausz NE; Simon AM; Hargrove L; Billard A
J Neuroeng Rehabil; 2018 Jun; 15(1):57. PubMed ID: 29940991
[TBL] [Abstract][Full Text] [Related]
5. Phase-Based Grasp Classification for Prosthetic Hand Control Using sEMG.
Wang S; Zheng J; Zheng B; Jiang X
Biosensors (Basel); 2022 Jan; 12(2):. PubMed ID: 35200318
[TBL] [Abstract][Full Text] [Related]
6. EMG Biofeedback for online predictive control of grasping force in a myoelectric prosthesis.
Dosen S; Markovic M; Somer K; Graimann B; Farina D
J Neuroeng Rehabil; 2015 Jun; 12():55. PubMed ID: 26088323
[TBL] [Abstract][Full Text] [Related]
7. Context-dependent adaptation improves robustness of myoelectric control for upper-limb prostheses.
Patel GK; Hahne JM; Castellini C; Farina D; Dosen S
J Neural Eng; 2017 Oct; 14(5):056016. PubMed ID: 28691694
[TBL] [Abstract][Full Text] [Related]
8. Enhanced visual feedback for slip prevention with a prosthetic hand.
Engeberg ED; Meek S
Prosthet Orthot Int; 2012 Dec; 36(4):423-9. PubMed ID: 22402709
[TBL] [Abstract][Full Text] [Related]
9. A Novel Myoelectric Control Scheme Supporting Synchronous Gesture Recognition and Muscle Force Estimation.
Hu R; Chen X; Zhang H; Zhang X; Chen X
IEEE Trans Neural Syst Rehabil Eng; 2022; 30():1127-1137. PubMed ID: 35412984
[TBL] [Abstract][Full Text] [Related]
10. Relationship between grasping force and features of single-channel intramuscular EMG signals.
Kamavuako EN; Farina D; Yoshida K; Jensen W
J Neurosci Methods; 2009 Dec; 185(1):143-50. PubMed ID: 19747943
[TBL] [Abstract][Full Text] [Related]
11. Tactile feedback is an effective instrument for the training of grasping with a prosthesis at low- and medium-force levels.
De Nunzio AM; Dosen S; Lemling S; Markovic M; Schweisfurth MA; Ge N; Graimann B; Falla D; Farina D
Exp Brain Res; 2017 Aug; 235(8):2547-2559. PubMed ID: 28550423
[TBL] [Abstract][Full Text] [Related]
12. Real-time myoelectric control of a multi-fingered hand prosthesis using principal components analysis.
Matrone GC; Cipriani C; Carrozza MC; Magenes G
J Neuroeng Rehabil; 2012 Jun; 9():40. PubMed ID: 22703711
[TBL] [Abstract][Full Text] [Related]
13. Myocontrol is closed-loop control: incidental feedback is sufficient for scaling the prosthesis force in routine grasping.
Markovic M; Schweisfurth MA; Engels LF; Farina D; Dosen S
J Neuroeng Rehabil; 2018 Sep; 15(1):81. PubMed ID: 30176929
[TBL] [Abstract][Full Text] [Related]
14. Evaluating the effect of non-invasive force feedback on prosthetic grasp force modulation in participants with and without limb loss.
Barontini F; Van Straaten M; Catalano MG; Thoreson A; Lopez C; Lennon R; Bianchi M; Andrews K; Santello M; Bicchi A; Zhao K
PLoS One; 2023; 18(5):e0285081. PubMed ID: 37141211
[TBL] [Abstract][Full Text] [Related]
15. Multisession, noninvasive closed-loop neuroprosthetic control of grasping by upper limb amputees.
Agashe HA; Paek AY; Contreras-Vidal JL
Prog Brain Res; 2016; 228():107-28. PubMed ID: 27590967
[TBL] [Abstract][Full Text] [Related]
16. A Systematic Study on Electromyography-Based Hand Gesture Recognition for Assistive Robots Using Deep Learning and Machine Learning Models.
Gopal P; Gesta A; Mohebbi A
Sensors (Basel); 2022 May; 22(10):. PubMed ID: 35632058
[TBL] [Abstract][Full Text] [Related]
17. Improved prosthetic hand control with concurrent use of myoelectric and inertial measurements.
Krasoulis A; Kyranou I; Erden MS; Nazarpour K; Vijayakumar S
J Neuroeng Rehabil; 2017 Jul; 14(1):71. PubMed ID: 28697795
[TBL] [Abstract][Full Text] [Related]
18. A Control Architecture for Grasp Strength Regulation in Myocontrolled Robotic Hands Using Vibrotactile Feedback: Preliminary Results.
Meattini R; Biagiotti L; Palli G; De Gregorio D; Melchiorri C
IEEE Int Conf Rehabil Robot; 2019 Jun; 2019():1272-1277. PubMed ID: 31374804
[TBL] [Abstract][Full Text] [Related]
19. Upper-Limb Electromyogram Classification of Reaching-to-Grasping Tasks Based on Convolutional Neural Networks for Control of a Prosthetic Hand.
Kim KT; Park S; Lim TH; Lee SJ
Front Neurosci; 2021; 15():733359. PubMed ID: 34712114
[TBL] [Abstract][Full Text] [Related]
20. Simultaneous sEMG Recognition of Gestures and Force Levels for Interaction With Prosthetic Hand.
Fang B; Wang C; Sun F; Chen Z; Shan J; Liu H; Ding W; Liang W
IEEE Trans Neural Syst Rehabil Eng; 2022; 30():2426-2436. PubMed ID: 35981072
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]