BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

184 related articles for article (PubMed ID: 30084065)

  • 41. Efficacy of s-type stents for the treatment of the main pancreatic duct stricture in patients with chronic pancreatitis.
    Ishihara T; Yamaguchi T; Seza K; Tadenuma H; Saisho H
    Scand J Gastroenterol; 2006 Jun; 41(6):744-50. PubMed ID: 16716976
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Long-term outcomes of fully covered self-expandable metal stents for refractory biliary strictures after living donor liver transplantation: a retrospective study at a tertiary center.
    Cho SH; Lee HS; Huh G; Oh D; Song TJ; Seo DW; Lee SK
    Surg Endosc; 2024 Jun; 38(6):3223-3230. PubMed ID: 38649493
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Long-term follow-up after multiple plastic stenting for refractory pancreatic duct strictures in chronic pancreatitis.
    Tringali A; Bove V; Vadalà di Prampero SF; Boškoski I; Familiari P; Perri V; Costamagna G
    Endoscopy; 2019 Oct; 51(10):930-935. PubMed ID: 31378858
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Comparison of clinical outcomes of multiple plastic stents and covered metal stent in refractory pancreatic ductal strictures in chronic pancreatitis- a systematic review and meta-analysis.
    Sofi AA; Khan MA; Ahmad S; Khan Z; Peerzada MM; Sunguk J; Vargo J
    Pancreatology; 2021 Aug; 21(5):854-861. PubMed ID: 33941467
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Application of Fully Covered Self-Expandable Metallic Stents with and without Antimigration Waist Versus Repeated Plastic Biliary Stent Placement in Management of Anastomotic Biliary Strictures After Orthotopic Liver Transplantation.
    Zeair S; Butkiewicz F; Butkiewicz J; Stasiuk R
    Ann Transplant; 2017 Dec; 22():719-724. PubMed ID: 29192137
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Management of biliary complications in liver transplant recipients using a fully covered self-expandable metal stent with antimigration features.
    Canakis A; Gilman AJ; Baron TH
    Minerva Gastroenterol (Torino); 2024 Jun; 70(2):181-186. PubMed ID: 37162469
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Endoscopic treatment of hepaticojejunostomy anastomotic strictures using fully-covered metal stents.
    Sato T; Kogure H; Nakai Y; Kanai S; Ishigaki K; Hakuta R; Saito K; Saito T; Takahara N; Hamada T; Mizuno S; Yamada A; Isayama H; Koike K
    Dig Endosc; 2021 Mar; 33(3):451-457. PubMed ID: 32559351
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Double Radiofrequency Ablation with Metal Stent Placement for Refractory Benign Biliary and Pancreatic Duct Strictures.
    Inoue T; Kitano R; Ito K; Yoneda M
    J Gastrointestin Liver Dis; 2020 Jun; 29(2):144. PubMed ID: 32530979
    [No Abstract]   [Full Text] [Related]  

  • 49. Feasibility of the unilateral-flange stent for the treatment of benign pancreatic duct stricture: a pilot study.
    Bhanthumkomol P; Hara K; Mizuno N; Hijioka S; Okuno N; Yoshida T; Tokuhisa J; Siramolpiwat S; Vilaichone RK; Pornthisarn B; Niwa Y; Tajika M; Tanaka T; Ishihara M; Hirayama Y; Yamao K
    Nagoya J Med Sci; 2017 Nov; 79(4):453-458. PubMed ID: 29238101
    [TBL] [Abstract][Full Text] [Related]  

  • 50. The use of double lasso, fully covered self-expandable metal stents with new "anchoring flap" system in the treatment of benign biliary diseases.
    Mangiavillano B; Manes G; Baron TH; Frego R; Dinelli M; Radaelli F; Teruzzi V; Amato A; Pallotta S; Santoro T; Masci E
    Dig Dis Sci; 2014 Sep; 59(9):2308-13. PubMed ID: 24748231
    [TBL] [Abstract][Full Text] [Related]  

  • 51. A fully covered self-expandable metal stent with antimigration features for benign biliary strictures: a prospective, multicenter cohort study.
    Walter D; Laleman W; Jansen JM; van Milligen de Wit AW; Weusten BL; van Boeckel PG; Hirdes MM; Vleggaar FP; Siersema PD
    Gastrointest Endosc; 2015 May; 81(5):1197-203. PubMed ID: 25660982
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Self-Expandable Metallic Stent Is More Cost Efficient Than Plastic Stent in Treating Anastomotic Biliary Stricture.
    Jang S; Stevens T; Lopez R; Chahal P; Bhatt A; Sanaka M; Vargo JJ
    Dig Dis Sci; 2020 Feb; 65(2):600-608. PubMed ID: 31104197
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Expandable metal stents for benign pancreatic duct obstruction.
    Eisendrath P; Devière J
    Gastrointest Endosc Clin N Am; 1999 Jul; 9(3):547-54. PubMed ID: 10390335
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Management of Benign Biliary Stricture in Chronic Pancreatitis.
    Ramchandani M; Pal P; Costamagna G
    Gastrointest Endosc Clin N Am; 2023 Oct; 33(4):831-844. PubMed ID: 37709414
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Placement of a 6 mm, fully covered metal stent for main pancreatic head duct stricture due to chronic pancreatitis: a pilot study (with video).
    Ogura T; Onda S; Takagi W; Kitano M; Sano T; Okuda A; Miyano A; Masuda D; Takeuchi T; Fukunishi S; Higuchi K
    Therap Adv Gastroenterol; 2016 Sep; 9(5):722-8. PubMed ID: 27582885
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Endoscopic therapy using a self-expandable metallic stent with an anti-migration system for postorthotopic liver transplantation anastomotic biliary stricture.
    Pinheiro LW; Martins FP; De Paulo GA; Contini MLC; Ferrari AP; Della Libera E
    World J Gastrointest Endosc; 2022 Sep; 14(9):547-554. PubMed ID: 36186946
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Endoscopic management of pancreatic duct stricture in chronic pancreatitis: Are fully covered self-expandable metallic stents ready for prime time?
    Ang TL
    J Gastroenterol Hepatol; 2020 Jul; 35(7):1093-1094. PubMed ID: 32648263
    [No Abstract]   [Full Text] [Related]  

  • 58. Evaluation of a newly modified nonflared fully covered metal stent, 12 mm in diameter, for intraductal placement in patients with malignant biliary strictures: a feasibility study.
    Choi HJ; Moon JH; Lee YN; Kim HS; Choi MH; Lee TH; Cha SW; Cho YD; Park SH; Kim SJ
    Endoscopy; 2016 Jul; 48(7):625-31. PubMed ID: 27110694
    [TBL] [Abstract][Full Text] [Related]  

  • 59. The utility of self-expanding metal stents in benign biliary strictures- a retrospective case series.
    Mallette K; Hawel J; Elnahas A; Alkhamesi NA; Schlachta CM; Tang ES
    BMC Gastroenterol; 2023 Oct; 23(1):361. PubMed ID: 37865737
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Intraductal placement of non-flared fully covered metallic stent for refractory anastomotic biliary strictures after living donor liver transplantation: Long-term results of prospective multicenter trial.
    Yoo JJ; Lee JK; Moon JH; Lee YN; Park JK; Lee KT; Lee KH; Lee WJ; Woo SM; Lee TH; Park SH
    J Gastroenterol Hepatol; 2020 Mar; 35(3):492-498. PubMed ID: 31418477
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.