These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
125 related articles for article (PubMed ID: 30086827)
1. Employing neutral-voltage spectrum for internal turn-to-turn fault detection in the induction machine drives. Jafarian MJ; Nazarzadeh J ISA Trans; 2018 Oct; 81():306-317. PubMed ID: 30086827 [TBL] [Abstract][Full Text] [Related]
2. Winding Tensor Approach for the Analytical Computation of the Inductance Matrix in Eccentric Induction Machines. Martinez-Roman J; Puche-Panadero R; Sapena-Bano A; Pineda-Sanchez M; Perez-Cruz J; Riera-Guasp M Sensors (Basel); 2020 May; 20(11):. PubMed ID: 32481710 [TBL] [Abstract][Full Text] [Related]
3. Partial Inductance Model of Induction Machines for Fault Diagnosis. Pineda-Sanchez M; Puche-Panadero R; Martinez-Roman J; Sapena-Bano A; Riera-Guasp M; Perez-Cruz J Sensors (Basel); 2018 Jul; 18(7):. PubMed ID: 30022017 [TBL] [Abstract][Full Text] [Related]
4. Simulative and experimental investigation on stator winding turn and unbalanced supply voltage fault diagnosis in induction motors using Artificial Neural Networks. Lashkari N; Poshtan J; Azgomi HF ISA Trans; 2015 Nov; 59():334-42. PubMed ID: 26412499 [TBL] [Abstract][Full Text] [Related]
5. Induction machine bearing faults detection based on a multi-dimensional MUSIC algorithm and maximum likelihood estimation. Elbouchikhi E; Choqueuse V; Benbouzid M ISA Trans; 2016 Jul; 63():413-424. PubMed ID: 27038887 [TBL] [Abstract][Full Text] [Related]
6. Incipient winding fault detection and diagnosis for squirrel-cage induction motors equipped on CRH trains. Wu Y; Jiang B; Wang Y ISA Trans; 2020 Apr; 99():488-495. PubMed ID: 31587810 [TBL] [Abstract][Full Text] [Related]
7. Fault Diagnosis in the Slip-Frequency Plane of Induction Machines Working in Time-Varying Conditions. Puche-Panadero R; Martinez-Roman J; Sapena-Bano A; Burriel-Valencia J; Riera-Guasp M Sensors (Basel); 2020 Jun; 20(12):. PubMed ID: 32560194 [TBL] [Abstract][Full Text] [Related]
8. Design and experimental validation for direct-drive fault-tolerant permanent-magnet vernier machines. Liu G; Yang J; Chen M; Chen Q ScientificWorldJournal; 2014; 2014():241085. PubMed ID: 25045729 [TBL] [Abstract][Full Text] [Related]
9. Diagnosis of broken-bars fault in induction machines using higher order spectral analysis. Saidi L; Fnaiech F; Henao H; Capolino GA; Cirrincione G ISA Trans; 2013 Jan; 52(1):140-8. PubMed ID: 22999985 [TBL] [Abstract][Full Text] [Related]
10. Induction Motor Stator Winding Inter-Tern Short Circuit Fault Detection Based on Start-Up Current Envelope Energy. Chen L; Shen J; Xu G; Chi C; Feng Q; Zhou Y; Deng Y; Wen H Sensors (Basel); 2023 Oct; 23(20):. PubMed ID: 37896674 [TBL] [Abstract][Full Text] [Related]
12. Induction distribution of five-phase induction machines under open-phase fault. Pereira LA; Nicol G; Pereira LFA; Perin M ISA Trans; 2020 Jan; 96():468-478. PubMed ID: 31204056 [TBL] [Abstract][Full Text] [Related]
13. PWM-switching pattern-based diagnosis scheme for single and multiple open-switch damages in VSI-fed induction motor drives. Trabelsi M; Boussak M; Gossa M ISA Trans; 2012 Mar; 51(2):333-44. PubMed ID: 22153956 [TBL] [Abstract][Full Text] [Related]
14. A differential electromagnetic induction torque sensor and its finite element analysis. Hao Z Rev Sci Instrum; 2015 May; 86(5):055003. PubMed ID: 26026550 [TBL] [Abstract][Full Text] [Related]
15. Detection of stator winding faults in induction motors using three-phase current monitoring. Sharifi R; Ebrahimi M ISA Trans; 2011 Jan; 50(1):14-20. PubMed ID: 21074767 [TBL] [Abstract][Full Text] [Related]
16. Cage-rotor induction motor inter-turn short circuit fault detection with and without saturation effect by MEC model. Naderi P ISA Trans; 2016 Sep; 64():216-230. PubMed ID: 27269192 [TBL] [Abstract][Full Text] [Related]
17. On-line diagnosis of inter-turn short circuit fault for DC brushed motor. Zhang J; Zhan W; Ehsani M ISA Trans; 2018 Jun; 77():179-187. PubMed ID: 29655844 [TBL] [Abstract][Full Text] [Related]
18. Cost-Effective Reduced Envelope of the Stator Current via Synchronous Sampling for the Diagnosis of Rotor Asymmetries in Induction Machines Working at Very Low Slip. Burriel-Valencia J; Puche-Panadero R; Martinez-Roman J; Sapena-Bano A; Pineda-Sanchez M Sensors (Basel); 2019 Aug; 19(16):. PubMed ID: 31398947 [TBL] [Abstract][Full Text] [Related]
19. Signal injection as a fault detection technique. Cusidó J; Romeral L; Ortega JA; Garcia A; Riba J Sensors (Basel); 2011; 11(3):3356-80. PubMed ID: 22163801 [TBL] [Abstract][Full Text] [Related]
20. Fault detection and diagnosis of induction motors using motor current signature analysis and a hybrid FMM-CART model. Seera M; Lim CP; Ishak D; Singh H IEEE Trans Neural Netw Learn Syst; 2012 Jan; 23(1):97-108. PubMed ID: 24808459 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]