These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 30086941)

  • 1. A single step electrochemical integration of gold nanoparticles, cholesterol oxidase, cholesterol esterase and mediator with polypyrrole films for fabrication of free and total cholesterol nanobiosensors.
    Rahim MZA; Govender-Hondros G; Adeloju SB
    Talanta; 2018 Nov; 189():418-428. PubMed ID: 30086941
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Synthesis of one-dimensional gold nanostructures and the electrochemical application of the nanohybrid containing functionalized graphene oxide for cholesterol biosensing.
    Nandini S; Nalini S; Reddy MB; Suresh GS; Melo JS; Niranjana P; Sanetuntikul J; Shanmugam S
    Bioelectrochemistry; 2016 Aug; 110():79-90. PubMed ID: 27100467
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fabrication of Pt/polypyrrole hybrid hollow microspheres and their application in electrochemical biosensing towards hydrogen peroxide.
    Bian X; Lu X; Jin E; Kong L; Zhang W; Wang C
    Talanta; 2010 May; 81(3):813-8. PubMed ID: 20298858
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of a novel biosensor based on a polypyrrole-dodecylbenzene sulphonate (PPy-DBS) film for the determination of amperometric cholesterol.
    Özer BO; Çete S
    Artif Cells Nanomed Biotechnol; 2017 Jun; 45(4):824-832. PubMed ID: 27571602
    [TBL] [Abstract][Full Text] [Related]  

  • 5. High-performance electrochemical biosensor for the detection of total cholesterol.
    Ahmadalinezhad A; Chen A
    Biosens Bioelectron; 2011 Jul; 26(11):4508-13. PubMed ID: 21646009
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simultaneous co-immobilization of three enzymes onto a modified glassy carbon electrode to fabricate a high-performance amperometric biosensor for determination of total cholesterol.
    Rashidi K; Mahmoudi M; Mohammadi G; Zangeneh MM; Korani S; Goicoechea HC; Gu HW; Jalalvand AR
    Int J Biol Macromol; 2018 Dec; 120(Pt A):587-595. PubMed ID: 30170050
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A micro-potentiometric hemoglobin immunosensor based on electropolymerized polypyrrole-gold nanoparticles composite.
    Qu L; Xia S; Bian C; Sun J; Han J
    Biosens Bioelectron; 2009 Aug; 24(12):3419-24. PubMed ID: 19110412
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Amperometric determination of serum total cholesterol with nanoparticles of cholesterol esterase and cholesterol oxidase.
    Aggarwal V; Malik J; Prashant A; Jaiwal PK; Pundir CS
    Anal Biochem; 2016 May; 500():6-11. PubMed ID: 26853742
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of biosensors based on entrapment of cholesterol oxidase and cholesterol esterase in electropolymerized films of polypyrrole and diaminonaphthalene derivatives for amperometric determination of cholesterol.
    Vidal JC; Garcia-Ruiz E; Espuelas J; Aramendia T; Castillo JR
    Anal Bioanal Chem; 2003 Sep; 377(2):273-80. PubMed ID: 12923606
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Caffeine electrochemical sensor using imprinted film as recognition element based on polypyrrole, sol-gel, and gold nanoparticles hybrid nanocomposite modified pencil graphite electrode.
    Rezaei B; Khalili Boroujeni M; Ensafi AA
    Biosens Bioelectron; 2014 Oct; 60():77-83. PubMed ID: 24769451
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Construction and evaluation of AuNPs enhanced electrochemical immunosensors with [Fe(CN)
    Zhao Q; Chen Z; Shan CW; Zhan T; Han CY; Han GC; Feng XZ; Kraatz HB
    Int J Biol Macromol; 2024 Jul; 273(Pt 1):132963. PubMed ID: 38852725
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Designing label-free electrochemical immunosensors for cytochrome c using nanocomposites functionalized screen printed electrodes.
    Pandiaraj M; Sethy NK; Bhargava K; Kameswararao V; Karunakaran C
    Biosens Bioelectron; 2014 Apr; 54():115-21. PubMed ID: 24262776
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Microstructural and potential dependence studies of urease-immobilized gold nanoparticles-polypyrrole composite film for urea detection.
    Rajesh ; Puri N; Mishra SK; Laskar MJ; Srivastava AK
    Appl Biochem Biotechnol; 2014 Jan; 172(2):1055-69. PubMed ID: 24142354
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Covalent immobilization of cholesterol oxidase on self-assembled gold nanoparticles for highly sensitive amperometric detection of cholesterol in real samples.
    Saxena U; Chakraborty M; Goswami P
    Biosens Bioelectron; 2011 Feb; 26(6):3037-43. PubMed ID: 21195602
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An amperometric bienzymatic cholesterol biosensor based on functionalized graphene modified electrode and its electrocatalytic activity towards total cholesterol determination.
    Manjunatha R; Shivappa Suresh G; Melo JS; D'Souza SF; Venkatesha TV
    Talanta; 2012 Sep; 99():302-9. PubMed ID: 22967556
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Polypyrrole based amperometric and potentiometric phosphate biosensors: a comparative study B.
    Lawal AT; Adeloju SB
    Biosens Bioelectron; 2013 Feb; 40(1):377-84. PubMed ID: 23021852
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A novel ultrasensitive phosphate amperometric nanobiosensor based on the integration of pyruvate oxidase with highly ordered gold nanowires array.
    Ogabiela E; Adeloju SB; Cui J; Wu Y; Chen W
    Biosens Bioelectron; 2015 Sep; 71():278-285. PubMed ID: 25913449
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Network nanostructured polypyrrole hydrogel/Au composites as enhanced electrochemical biosensing platform.
    Rong Q; Han H; Feng F; Ma Z
    Sci Rep; 2015 Jun; 5():11440. PubMed ID: 26074185
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of α-polyoxometalate-polypyrrole-Au nanoparticles modified sensor applied for detection of folic acid.
    Babakhanian A; Kaki S; Ahmadi M; Ehzari H; Pashabadi A
    Biosens Bioelectron; 2014 Oct; 60():185-90. PubMed ID: 24800683
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of an amperometric sulfite biosensor based on SO(x)/PBNPs/PPY modified ITO electrode.
    Rawal R; Pundir CS
    Int J Biol Macromol; 2012 Nov; 51(4):449-55. PubMed ID: 22705572
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.