These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

382 related articles for article (PubMed ID: 30096518)

  • 1. The relationship between end-expired carbon dioxide tension and severity of venous air embolism during sitting neurosurgical procedures - A contemporary analysis.
    Kapurch CJ; Abcejo AS; Pasternak JJ
    J Clin Anesth; 2018 Dec; 51():49-54. PubMed ID: 30096518
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of the degree of head elevation on the incidence and severity of venous air embolism in cranial neurosurgical procedures with patients in the semisitting position.
    Türe H; Harput MV; Bekiroğlu N; Keskin Ö; Köner Ö; Türe U
    J Neurosurg; 2018 May; 128(5):1560-1569. PubMed ID: 28707996
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Contemporary analysis of the intraoperative and perioperative complications of neurosurgical procedures performed in the sitting position.
    Himes BT; Mallory GW; Abcejo AS; Pasternak J; Atkinson JLD; Meyer FB; Marsh WR; Link MJ; Clarke MJ; Perkins W; Van Gompel JJ
    J Neurosurg; 2017 Jul; 127(1):182-188. PubMed ID: 27494821
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Detection of venous air embolism and patent foramen ovale in neurosurgery patients in sitting position].
    Hervías A; Valero R; Hurtado P; Gracia I; Perelló L; Tercero FJ; González JJ; Fàbregas N
    Neurocirugia (Astur); 2014; 25(3):108-15. PubMed ID: 24630436
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Neurosurgical procedures in the semisitting position: evaluation of the risk of paradoxical venous air embolism in patients with a patent foramen ovale.
    Feigl GC; Decker K; Wurms M; Krischek B; Ritz R; Unertl K; Tatagiba M
    World Neurosurg; 2014 Jan; 81(1):159-64. PubMed ID: 23295634
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sitting position for removal of pineal region lesions: the Helsinki experience.
    Lindroos AC; Niiya T; Randell T; Romani R; Hernesniemi J; Niemi T
    World Neurosurg; 2010; 74(4-5):505-13. PubMed ID: 21492603
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Neurosurgery in the sitting position: retrospective analysis of 692 adult and pediatric cases.
    Dilmen OK; Akcil EF; Tureci E; Tunali Y; Bahar M; Tanriverdi T; Aydin S; Yentur E
    Turk Neurosurg; 2011; 21(4):634-40. PubMed ID: 22194128
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Venous air embolism in the sitting position in cranial neurosurgery: incidence and severity according to the used monitoring.
    Günther F; Frank P; Nakamura M; Hermann EJ; Palmaers T
    Acta Neurochir (Wien); 2017 Feb; 159(2):339-346. PubMed ID: 27896454
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Venous air embolism: does the site of embolism influence the hemodynamic changes?
    Bithal P; Dash HH; Vishnoi N; Chaturvedi A
    Neurol India; 2003 Sep; 51(3):370-2. PubMed ID: 14652442
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Urgent Repositioning After Venous Air Embolism During Intracranial Surgery in the Seated Position: A Case Series.
    Abcejo AS; Pasternak JJ; Perkins WJ
    J Neurosurg Anesthesiol; 2019 Oct; 31(4):413-421. PubMed ID: 30148744
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Carbon dioxide field flooding reduces the hemodynamic effects of venous air embolism occurring in the sitting position.
    Longatti P; Marton E; Feletti A; Falzarano M; Canova G; Sorbara C
    Childs Nerv Syst; 2015 Aug; 31(8):1321-6. PubMed ID: 25953098
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Venous air embolism and the sitting position: a case series.
    Leslie K; Hui R; Kaye AH
    J Clin Neurosci; 2006 May; 13(4):419-22. PubMed ID: 16678719
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Venous air emboli occur during release of positive end-expiratory pressure and repositioning after sitting position surgery.
    Schmitt HJ; Hemmerling TM
    Anesth Analg; 2002 Feb; 94(2):400-3, table of contents. PubMed ID: 11812707
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An abrupt reduction in end-tidal carbon-dioxide during neurosurgery is not always due to venous air embolism: a capnograph artefact.
    Vinay B; Sriganesh K; Gopala Krishna KN
    J Clin Monit Comput; 2014 Apr; 28(2):217-9. PubMed ID: 23996497
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Transcutaneous O2 and CO2 monitoring of neurosurgical patients: detection of air embolism.
    Glenski JA; Cucchiara RF
    Anesthesiology; 1986 May; 64(5):546-50. PubMed ID: 3083725
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The sitting position in neurosurgery: indications, complications and results. a single institution experience of 600 cases.
    Ganslandt O; Merkel A; Schmitt H; Tzabazis A; Buchfelder M; Eyupoglu I; Muenster T
    Acta Neurochir (Wien); 2013 Oct; 155(10):1887-93. PubMed ID: 23925859
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparative incidence of cardiovascular changes during venous air embolism as detected by transesophageal echocardiography alone or in combination with end tidal carbon dioxide tension monitoring.
    Pandia MP; Bithal PK; Dash HH; Chaturvedi A
    J Clin Neurosci; 2011 Sep; 18(9):1206-9. PubMed ID: 21763144
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Incidence of venous and paradoxical air embolism in neurosurgical patients in the sitting position: detection by transesophageal echocardiography.
    Mammoto T; Hayashi Y; Ohnishi Y; Kuro M
    Acta Anaesthesiol Scand; 1998 Jul; 42(6):643-7. PubMed ID: 9689268
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparative incidence of venous air embolism and associated hypotension in adults and children operated for neurosurgery in the sitting position.
    Bithal PK; Pandia MP; Dash HH; Chouhan RS; Mohanty B; Padhy N
    Eur J Anaesthesiol; 2004 Jul; 21(7):517-22. PubMed ID: 15318462
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fifty percent nitrous oxide does not increase the risk of venous air embolism in neurosurgical patients operated upon in the sitting position.
    Losasso TJ; Muzzi DA; Dietz NM; Cucchiara RF
    Anesthesiology; 1992 Jul; 77(1):21-30. PubMed ID: 1609997
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.