146 related articles for article (PubMed ID: 30099059)
1. Typical readout durations in spiral cine DENSE yield blurred images and underestimate cardiac strains at both 3.0 T and 1.5 T.
Wehner GJ; Suever JD; Fielden SW; Powell DK; Hamlet SM; Vandsburger MH; Haggerty CM; Zhong X; Fornwalt BK
Magn Reson Imaging; 2018 Dec; 54():90-100. PubMed ID: 30099059
[TBL] [Abstract][Full Text] [Related]
2. Validation of in vivo 2D displacements from spiral cine DENSE at 3T.
Wehner GJ; Suever JD; Haggerty CM; Jing L; Powell DK; Hamlet SM; Grabau JD; Mojsejenko WD; Zhong X; Epstein FH; Fornwalt BK
J Cardiovasc Magn Reson; 2015 Jan; 17(1):5. PubMed ID: 25634468
[TBL] [Abstract][Full Text] [Related]
3. Myocardial strain in healthy adults across a broad age range as revealed by cardiac magnetic resonance imaging at 1.5 and 3.0T: Associations of myocardial strain with myocardial region, age, and sex.
Mangion K; Clerfond G; McComb C; Carrick D; Rauhalammi SM; McClure J; Corcoran DS; Woodward R; Orchard V; Radjenovic A; Zhong X; Berry C
J Magn Reson Imaging; 2016 Nov; 44(5):1197-1205. PubMed ID: 27104306
[TBL] [Abstract][Full Text] [Related]
4. Optimal configuration of respiratory navigator gating for the quantification of left ventricular strain using spiral cine displacement encoding with stimulated echoes (DENSE) MRI.
Hamlet SM; Haggerty CM; Suever JD; Wehner GJ; Andres KN; Powell DK; Zhong X; Fornwalt BK
J Magn Reson Imaging; 2017 Mar; 45(3):786-794. PubMed ID: 27458823
[TBL] [Abstract][Full Text] [Related]
5. Accelerated two-dimensional cine DENSE cardiovascular magnetic resonance using compressed sensing and parallel imaging.
Chen X; Yang Y; Cai X; Auger DA; Meyer CH; Salerno M; Epstein FH
J Cardiovasc Magn Reson; 2016 Jun; 18(1):38. PubMed ID: 27301487
[TBL] [Abstract][Full Text] [Related]
6. Demonstration of circumferential heterogeneity in displacement and strain in the abdominal aortic wall by spiral cine DENSE MRI.
Iffrig E; Wilson JS; Zhong X; Oshinski JN
J Magn Reson Imaging; 2019 Mar; 49(3):731-743. PubMed ID: 30295345
[TBL] [Abstract][Full Text] [Related]
7. 2D cine DENSE with low encoding frequencies accurately quantifies cardiac mechanics with improved image characteristics.
Wehner GJ; Grabau JD; Suever JD; Haggerty CM; Jing L; Powell DK; Hamlet SM; Vandsburger MH; Zhong X; Fornwalt BK
J Cardiovasc Magn Reson; 2015 Nov; 17():93. PubMed ID: 26538111
[TBL] [Abstract][Full Text] [Related]
8. An interactive videogame designed to improve respiratory navigator efficiency in children undergoing cardiovascular magnetic resonance.
Hamlet SM; Haggerty CM; Suever JD; Wehner GJ; Grabau JD; Andres KN; Vandsburger MH; Powell DK; Sorrell VL; Fornwalt BK
J Cardiovasc Magn Reson; 2016 Sep; 18(1):54. PubMed ID: 27599620
[TBL] [Abstract][Full Text] [Related]
9. The feasibility of a novel limited field of view spiral cine DENSE sequence to assess myocardial strain in dilated cardiomyopathy.
Tayal U; Wage R; Ferreira PF; Nielles-Vallespin S; Epstein FH; Auger D; Zhong X; Pennell DJ; Firmin DN; Scott AD; Prasad SK
MAGMA; 2019 Jun; 32(3):317-329. PubMed ID: 30694416
[TBL] [Abstract][Full Text] [Related]
10. Introduction to a mechanism for automated myocardium boundary detection with displacement encoding with stimulated echoes (DENSE).
Kar J; Zhong X; Cohen MV; Cornejo DA; Yates-Judice A; Rel E; Figarola MS
Br J Radiol; 2018 Jul; 91(1087):20170841. PubMed ID: 29565646
[TBL] [Abstract][Full Text] [Related]
11. In Vitro Validation of Regional Circumferential Strain Assessment in a Phantom Aortic Model Using Cine Displacement Encoding With Stimulated Echoes MRI.
Wilson JS; Islam M; Oshinski JN
J Magn Reson Imaging; 2022 Jun; 55(6):1773-1784. PubMed ID: 34704637
[TBL] [Abstract][Full Text] [Related]
12. High resolution in-vivo DT-CMR using an interleaved variable density spiral STEAM sequence.
Gorodezky M; Ferreira PF; Nielles-Vallespin S; Gatehouse PD; Pennell DJ; Scott AD; Firmin DN
Magn Reson Med; 2019 Mar; 81(3):1580-1594. PubMed ID: 30408238
[TBL] [Abstract][Full Text] [Related]
13. Imaging three-dimensional myocardial mechanics using navigator-gated volumetric spiral cine DENSE MRI.
Zhong X; Spottiswoode BS; Meyer CH; Kramer CM; Epstein FH
Magn Reson Med; 2010 Oct; 64(4):1089-97. PubMed ID: 20574967
[TBL] [Abstract][Full Text] [Related]
14. Three-dimensional regional strain computation method with displacement encoding with stimulated echoes (DENSE) in non-ischemic, non-valvular dilated cardiomyopathy patients and healthy subjects validated by tagged MRI.
Kar J; Knutsen AK; Cupps BP; Zhong X; Pasque MK
J Magn Reson Imaging; 2015 Feb; 41(2):386-96. PubMed ID: 24753028
[TBL] [Abstract][Full Text] [Related]
15. Imaging left-ventricular mechanical activation in heart failure patients using cine DENSE MRI: Validation and implications for cardiac resynchronization therapy.
Auger DA; Bilchick KC; Gonzalez JA; Cui SX; Holmes JW; Kramer CM; Salerno M; Epstein FH
J Magn Reson Imaging; 2017 Sep; 46(3):887-896. PubMed ID: 28067978
[TBL] [Abstract][Full Text] [Related]
16. Reproducibility of cine displacement encoding with stimulated echoes (DENSE) in human subjects.
Lin K; Meng L; Collins JD; Chowdhary V; Markl M; Carr JC
Magn Reson Imaging; 2017 Jan; 35():148-153. PubMed ID: 27569367
[TBL] [Abstract][Full Text] [Related]
17. Free-breathing cine DENSE MRI using phase cycling with matchmaking and stimulated-echo image-based navigators.
Cai X; Epstein FH
Magn Reson Med; 2018 Nov; 80(5):1907-1921. PubMed ID: 29607538
[TBL] [Abstract][Full Text] [Related]
18. Circumferential strain in the wall of the common carotid artery: comparing displacement-encoded and cine MRI in volunteers.
Lin AP; Bennett E; Wisk LE; Gharib M; Fraser SE; Wen H
Magn Reson Med; 2008 Jul; 60(1):8-13. PubMed ID: 18581403
[TBL] [Abstract][Full Text] [Related]
19. Real-time SPARSE-SENSE cardiac cine MR imaging: optimization of image reconstruction and sequence validation.
Goebel J; Nensa F; Bomas B; Schemuth HP; Maderwald S; Gratz M; Quick HH; Schlosser T; Nassenstein K
Eur Radiol; 2016 Dec; 26(12):4482-4489. PubMed ID: 26960537
[TBL] [Abstract][Full Text] [Related]
20. Increasing the signal-to-noise ratio in DENSE MRI by combining displacement-encoded echoes.
Kim D; Epstein FH; Gilson WD; Axel L
Magn Reson Med; 2004 Jul; 52(1):188-92. PubMed ID: 15236385
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]