These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

288 related articles for article (PubMed ID: 30103843)

  • 21. Conductive Leaflike Cobalt Metal-Organic Framework Nanoarray on Carbon Cloth as a Flexible and Versatile Anode toward Both Electrocatalytic Glucose and Water Oxidation.
    Wei Z; Zhu W; Li Y; Ma Y; Wang J; Hu N; Suo Y; Wang J
    Inorg Chem; 2018 Jul; 57(14):8422-8428. PubMed ID: 29956927
    [TBL] [Abstract][Full Text] [Related]  

  • 22. MOF-derived high-density carbon nanotubes "tentacle" with boosting electrocatalytic activity for detecting ascorbic acid.
    Zhang Y; Han M; Peng D; Qin H; Zheng H; Xiao J; Yang N
    Talanta; 2024 Nov; 279():126578. PubMed ID: 39032458
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Direct growth of metal-organic frameworks thin film arrays on glassy carbon electrode based on rapid conversion step mediated by copper clusters and hydroxide nanotubes for fabrication of a high performance non-enzymatic glucose sensing platform.
    Shahrokhian S; Khaki Sanati E; Hosseini H
    Biosens Bioelectron; 2018 Jul; 112():100-107. PubMed ID: 29702380
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A simple ultrasensitive electrochemical sensor for simultaneous determination of gallic acid and uric acid in human urine and fruit juices based on zirconia-choline chloride-gold nanoparticles-modified carbon paste electrode.
    Shahamirifard SA; Ghaedi M; Razmi Z; Hajati S
    Biosens Bioelectron; 2018 Aug; 114():30-36. PubMed ID: 29775856
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Optimization of modified carbon paste electrode with multiwalled carbon nanotube/ionic liquid/cauliflower-like gold nanostructures for simultaneous determination of ascorbic acid, dopamine and uric acid.
    Afraz A; Rafati AA; Najafi M
    Mater Sci Eng C Mater Biol Appl; 2014 Nov; 44():58-68. PubMed ID: 25280680
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Preparation and characterization of PtAu hybrid film modified electrodes and their use in simultaneous determination of dopamine, ascorbic acid and uric acid.
    Thiagarajan S; Chen SM
    Talanta; 2007 Nov; 74(2):212-22. PubMed ID: 18371632
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Ultrasmall Au(0) Inserted Hollow PCN-222 MOF for The High-Sensitive Detection of Estradiol.
    Biswas S; Chen Y; Xie Y; Sun X; Wang Y
    Anal Chem; 2020 Mar; 92(6):4566-4572. PubMed ID: 32077686
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparative electrochemical study of new self-assembled monolayers of 2-{[(Z)-1-(3-furyl)methylidene]amino}-1-benzenethiol and 2-{[(2-sulfanylphenyl)imino]methyl}phenol for determination of dopamine in the presence of high concentration of ascorbic acid and uric acid.
    Behpour M; Ghoreishi SM; Honarmand E; Salavati-Niasari M
    Analyst; 2011 May; 136(9):1979-86. PubMed ID: 21409249
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Study of the electrocatalytic activity of cerium oxide and gold-studded cerium oxide nanoparticles using a Sonogel-Carbon material as supporting electrode: electroanalytical study in apple juice for babies.
    Abdelrahim MY; Benjamin SR; Cubillana-Aguilera LM; Naranjo-Rodríguez I; de Cisneros JL; Delgado JJ; Palacios-Santander JM
    Sensors (Basel); 2013 Apr; 13(4):4979-5007. PubMed ID: 23584124
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Determination of dopamine in presence of ascorbic acid and uric acid using poly (Spands Reagent) modified carbon paste electrode.
    Veera Manohara Reddy Y; Prabhakara Rao V; Vijaya Bhaskar Reddy A; Lavanya M; Venu M; Lavanya M; Madhavi G
    Mater Sci Eng C Mater Biol Appl; 2015 Dec; 57():378-86. PubMed ID: 26354279
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Graphite/Ag/AgCl nanocomposite as a new and highly efficient electrocatalyst for selective electroxidation of oxalic acid and its assay in real samples.
    Alizadeh T; Nayeri S
    Mater Sci Eng C Mater Biol Appl; 2019 Jul; 100():826-836. PubMed ID: 30948120
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Covalent organic framework derived Fe
    Lu Z; Shi Z; Huang S; Zhang R; Li G; Hu Y
    Talanta; 2020 Jul; 214():120864. PubMed ID: 32278408
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Poly(3,4-ethylenedioxythiophene-co-(5-amino-2-naphthalenesulfonic acid)) (PEDOT-PANS) film modified glassy carbon electrode for selective detection of dopamine in the presence of ascorbic acid and uric acid.
    Balamurugan A; Chen SM
    Anal Chim Acta; 2007 Jul; 596(1):92-8. PubMed ID: 17616245
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A poly(3-acetylthiophene) modified glassy carbon electrode for selective voltammetric measurement of uric acid in urine sample.
    Aslanoglu M; Kutluay A; Abbasoglu S; Karabulut S
    Chem Pharm Bull (Tokyo); 2008 Mar; 56(3):282-6. PubMed ID: 18310936
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Simultaneous and sensitive determination of ascorbic acid, dopamine, uric acid, and tryptophan with silver nanoparticles-decorated reduced graphene oxide modified electrode.
    Kaur B; Pandiyan T; Satpati B; Srivastava R
    Colloids Surf B Biointerfaces; 2013 Nov; 111():97-106. PubMed ID: 23777794
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Simultaneous determination of dopamine, ascorbic acid, and uric acid using carbon ionic liquid electrode.
    Safavi A; Maleki N; Moradlou O; Tajabadi F
    Anal Biochem; 2006 Dec; 359(2):224-9. PubMed ID: 17069745
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Modification of carbon paste electrode with Fe(III)-clinoptilolite nano-particles for simultaneous voltammetric determination of acetaminophen and ascorbic acid.
    Sharifian S; Nezamzadeh-Ejhieh A
    Mater Sci Eng C Mater Biol Appl; 2016 Jan; 58():510-20. PubMed ID: 26478339
    [TBL] [Abstract][Full Text] [Related]  

  • 38. An electrochemical ascorbic acid sensor based on palladium nanoparticles supported on graphene oxide.
    Wu GH; Wu YF; Liu XW; Rong MC; Chen XM; Chen X
    Anal Chim Acta; 2012 Oct; 745():33-7. PubMed ID: 22938603
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Amperometric ascorbic acid sensor based on doped ferrites nanoparticles modified glassy carbon paste electrode.
    Dimitrijević T; Vulić P; Manojlović D; Nikolić AS; Stanković DM
    Anal Biochem; 2016 Jul; 504():20-6. PubMed ID: 27059753
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Employing Conductive Metal-Organic Frameworks for Voltammetric Detection of Neurochemicals.
    Ko M; Mendecki L; Eagleton AM; Durbin CG; Stolz RM; Meng Z; Mirica KA
    J Am Chem Soc; 2020 Jul; 142(27):11717-11733. PubMed ID: 32155057
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 15.