These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 30104613)

  • 1. Novel clinical device tracking and tissue event characterization using proximally placed audio signal acquisition and processing.
    Illanes A; Boese A; Maldonado I; Pashazadeh A; Schaufler A; Navab N; Friebe M
    Sci Rep; 2018 Aug; 8(1):12070. PubMed ID: 30104613
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Proximal detection of guide wire perforation using feature extraction from bispectral audio signal analysis combined with machine learning.
    Mahmoodian N; Schaufler A; Pashazadeh A; Boese A; Friebe M; Illanes A
    Comput Biol Med; 2019 Apr; 107():10-17. PubMed ID: 30769168
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Texture differentiation using audio signal analysis with robotic interventional instruments.
    Chen CH; Sühn T; Kalmar M; Maldonado I; Wex C; Croner R; Boese A; Friebe M; Illanes A
    Comput Biol Med; 2019 Sep; 112():103370. PubMed ID: 31374348
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Study of needle punctures into soft tissue through audio and force sensing: can audio be a simple alternative for needle guidance?
    Sabieleish M; Heryan K; Boese A; Hansen C; Friebe M; Illanes A
    Int J Comput Assist Radiol Surg; 2021 Oct; 16(10):1683-1697. PubMed ID: 34652603
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Precise application of Traditional Chinese Medicine in minimally-invasive techniques].
    Dong FH
    Zhongguo Gu Shang; 2018 Jun; 31(6):493-496. PubMed ID: 29945400
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Analysis of a vibrating interventional device to improve 3-D colormark tracking.
    Fronheiser MP; Smith SW
    IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Aug; 54(8):1700-7. PubMed ID: 17703675
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Navigation with electromagnetic tracking for interventional radiology procedures: a feasibility study.
    Wood BJ; Zhang H; Durrani A; Glossop N; Ranjan S; Lindisch D; Levy E; Banovac F; Borgert J; Krueger S; Kruecker J; Viswanathan A; Cleary K
    J Vasc Interv Radiol; 2005 Apr; 16(4):493-505. PubMed ID: 15802449
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of Sound Features for Needle Perforation Event Detection.
    Renna F; Illanes A; Oliveira J; Esmaeili N; Friebe M; Coimbra MT
    Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():2597-2600. PubMed ID: 31946428
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Modeling of path planning and needle steering with path tracking in anatomical soft tissues for minimally invasive surgery.
    Li P; Jiang S; Liang D; Yang Z; Yu Y; Wang W
    Med Eng Phys; 2017 Mar; 41():35-45. PubMed ID: 28100406
    [TBL] [Abstract][Full Text] [Related]  

  • 10. New method to monitor RF safety in MRI-guided interventions based on RF induced image artefacts.
    van den Bosch MR; Moerland MA; Lagendijk JJ; Bartels LW; van den Berg CA
    Med Phys; 2010 Feb; 37(2):814-21. PubMed ID: 20229891
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Complication management in minimally invasive surgery].
    Müller-Stich BP; Büchler MW
    Chirurg; 2015 Dec; 86(12):1095-6. PubMed ID: 26541447
    [No Abstract]   [Full Text] [Related]  

  • 12. [Anatomy notes on minimally invasive plate osteosynthesis of the proximal humerus. A cadaver study].
    Křivohlávek M; Taller S; Lukáš R; Dráč P
    Acta Chir Orthop Traumatol Cech; 2014; 81(1):63-9. PubMed ID: 24755059
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Needle-tissue interactive mechanism and steering control in image-guided robot-assisted minimally invasive surgery: a review.
    Li P; Yang Z; Jiang S
    Med Biol Eng Comput; 2018 Jun; 56(6):931-949. PubMed ID: 29679255
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Acoustic characterization of stethoscopes using auscultation sounds as test signals.
    Nowak LJ; Nowak KM
    J Acoust Soc Am; 2017 Mar; 141(3):1940. PubMed ID: 28372089
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of magnetic resonance imaging-compatible needles and interactive sequences for musculoskeletal interventions using an open high-field magnetic resonance imaging scanner.
    Wonneberger U; Schnackenburg B; Streitparth F; Walter T; Rump J; Teichgräber UK
    Cardiovasc Intervent Radiol; 2010 Apr; 33(2):346-51. PubMed ID: 19705200
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Computer-assisted navigation system for interventional CT-guided procedures: results of phantom and clinical studies].
    Meier-Meitinger M; Nagel M; Kalender W; Bautz WA; Baum U
    Rofo; 2008 Apr; 180(4):310-7. PubMed ID: 18499907
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Sound differences between electronic and acoustic stethoscopes.
    Nowak LJ; Nowak KM
    Biomed Eng Online; 2018 Aug; 17(1):104. PubMed ID: 30075781
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Tissue resistance to soft tissue emphysema during minimally invasive periodontal surgery.
    Harrel SK; Abraham CM; Rivera-Hidalgo F
    J Contemp Dent Pract; 2012 Nov; 13(6):886-91. PubMed ID: 23404021
    [TBL] [Abstract][Full Text] [Related]  

  • 19. OneShot-M: A New Device for Close Laparoscopy Pneumoperitoneum.
    Cassata G; Palumbo V; Cicero L; De Luca A; Damiano G; Fazzotta S; Buscemi S; Lo Monte AI
    Surg Innov; 2018 Dec; 25(6):570-577. PubMed ID: 30196768
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Risk awareness and training for prevention of complications in minimally invasive surgery].
    Nickel F; Kowalewski KF; Müller-Stich BP
    Chirurg; 2015 Dec; 86(12):1121-7. PubMed ID: 26464347
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.