These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
201 related articles for article (PubMed ID: 30107489)
21. Cardiovascular Magnetic Resonance to Predict Appropriate Implantable Cardioverter Defibrillator Therapy in Ischemic and Nonischemic Cardiomyopathy Patients Using Late Gadolinium Enhancement Border Zone: Comparison of Four Analysis Methods. Jablonowski R; Chaudhry U; van der Pals J; Engblom H; Arheden H; Heiberg E; Wu KC; Borgquist R; Carlsson M Circ Cardiovasc Imaging; 2017 Sep; 10(9):. PubMed ID: 28838961 [TBL] [Abstract][Full Text] [Related]
22. Primary prevention implantable cardioverter defibrillator in patients with non-ischaemic cardiomyopathy: a meta-analysis of randomised controlled trials. Barakat AF; Saad M; Elgendy AY; Mentias A; Abuzaid A; Mahmoud AN; Elgendy IY BMJ Open; 2017 Jun; 7(6):e016352. PubMed ID: 28637742 [TBL] [Abstract][Full Text] [Related]
23. Magnetic resonance estimates of the extent and heterogeneity of scar tissue in ICD patients with ischemic cardiomyopathy predict ventricular arrhythmia. Zeidan-Shwiri T; Yang Y; Lashevsky I; Kadmon E; Kagal D; Dick A; Laish Farkash A; Paul G; Gao D; Shurrab M; Newman D; Wright G; Crystal E Heart Rhythm; 2015 Apr; 12(4):802-8. PubMed ID: 25583153 [TBL] [Abstract][Full Text] [Related]
25. Efficacy of Implantable Cardioverter-Defibrillator Therapy in Patients With Nonischemic Cardiomyopathy: A Systematic Review and Meta-Analysis of Randomized Controlled Trials. Anantha Narayanan M; Vakil K; Reddy YN; Baskaran J; Deshmukh A; Benditt DG; Adabag S JACC Clin Electrophysiol; 2017 Sep; 3(9):962-970. PubMed ID: 29759721 [TBL] [Abstract][Full Text] [Related]
26. Implantable defibrillators for the prevention of mortality in patients with nonischemic cardiomyopathy: a meta-analysis of randomized controlled trials. Desai AS; Fang JC; Maisel WH; Baughman KL JAMA; 2004 Dec; 292(23):2874-9. PubMed ID: 15598919 [TBL] [Abstract][Full Text] [Related]
27. Comparison of Mortality and Readmission in Non-Ischemic Versus Ischemic Cardiomyopathy After Implantable Cardioverter-Defibrillator Implantation. Higgins AY; Bjerre J; Parzynski CS; Minges KE; Ahmad T; Desai NR; Enriquez A; Spatz ES; Friedman DJ; Curtis JP; Hlatky MA; Freeman JV Am J Cardiol; 2020 Oct; 133():116-125. PubMed ID: 32862971 [TBL] [Abstract][Full Text] [Related]
28. Value of CMR and PET in Predicting Ventricular Arrhythmias in Ischemic Cardiomyopathy Patients Eligible for ICD. Rijnierse MT; van der Lingen ACJ; de Haan S; Becker MAJ; Harms HJ; Huisman MC; Lammertsma AA; van de Ven PM; van Rossum AC; Knaapen P; Allaart CP JACC Cardiovasc Imaging; 2020 Aug; 13(8):1755-1766. PubMed ID: 32305468 [TBL] [Abstract][Full Text] [Related]
29. Role of implantable cardioverter defibrillator in non-ischemic cardiomyopathy: a systematic review and meta-analysis of prospective randomized clinical trials. Romero J; Chaudhary R; Garg J; Lupercio F; Shah N; Gupta R; Nazir T; Bozorgnia B; Natale A; Di Biase L J Interv Card Electrophysiol; 2017 Sep; 49(3):263-270. PubMed ID: 28674918 [TBL] [Abstract][Full Text] [Related]
30. Usefulness of Left Atrial Emptying Fraction to Predict Ventricular Arrhythmias in Patients With Implantable Cardioverter Defibrillators. Rijnierse MT; Kamali Sadeghian M; Schuurmans Stekhoven S; Biesbroek PS; van der Lingen AC; van de Ven PM; van Rossum AC; Nijveldt R; Allaart CP Am J Cardiol; 2017 Jul; 120(2):243-250. PubMed ID: 28532781 [TBL] [Abstract][Full Text] [Related]
31. Cardiac MRI scar patterns differ by sex in an implantable cardioverter-defibrillator and cardiac resynchronization therapy cohort. Loring Z; Strauss DG; Gerstenblith G; Tomaselli GF; Weiss RG; Wu KC Heart Rhythm; 2013 May; 10(5):659-65. PubMed ID: 23313802 [TBL] [Abstract][Full Text] [Related]
32. Absence of late gadolinium enhancement on cardiac magnetic resonance imaging in ventricular fibrillation and nonischemic cardiomyopathy. Voskoboinik A; Wong MCG; Elliott JK; Costello BT; Prabhu S; Mariani JA; Kalman JM; Kistler PM; Taylor AJ; Morton JB Pacing Clin Electrophysiol; 2018 Sep; 41(9):1109-1115. PubMed ID: 29931686 [TBL] [Abstract][Full Text] [Related]
33. The relationship between left ventricular scar and ventricular repolarization in patients with coronary artery disease: insights from late gadolinium enhancement magnetic resonance imaging. Scott PA; Rosengarten JA; Shahed A; Yue AM; Murday DC; Roberts PR; Peebles CR; Harden SP; Curzen NP; Morgan JM Europace; 2013 Jun; 15(6):899-906. PubMed ID: 23143860 [TBL] [Abstract][Full Text] [Related]
34. Left ventricular geometry predicts ventricular tachyarrhythmia in patients with left ventricular systolic dysfunction: a comprehensive cardiovascular magnetic resonance study. Nakamori S; Ismail H; Ngo LH; Manning WJ; Nezafat R J Cardiovasc Magn Reson; 2017 Oct; 19(1):79. PubMed ID: 29058590 [TBL] [Abstract][Full Text] [Related]
35. Entropy as a Novel Measure of Myocardial Tissue Heterogeneity for Prediction of Ventricular Arrhythmias and Mortality in Post-Infarct Patients. Androulakis AFA; Zeppenfeld K; Paiman EHM; Piers SRD; Wijnmaalen AP; Siebelink HJ; Sramko M; Lamb HJ; van der Geest RJ; de Riva M; Tao Q JACC Clin Electrophysiol; 2019 Apr; 5(4):480-489. PubMed ID: 31000102 [TBL] [Abstract][Full Text] [Related]
36. Myocardial fibrosis predicts appropriate device therapy in patients with implantable cardioverter-defibrillators for primary prevention of sudden cardiac death. Iles L; Pfluger H; Lefkovits L; Butler MJ; Kistler PM; Kaye DM; Taylor AJ J Am Coll Cardiol; 2011 Feb; 57(7):821-8. PubMed ID: 21310318 [TBL] [Abstract][Full Text] [Related]
37. Associations between scar characteristics by cardiac magnetic resonance and changes in left ventricular ejection fraction in primary prevention defibrillator recipients. Zhang Y; Guallar E; Weiss RG; Stillabower M; Gerstenblith G; Tomaselli GF; Wu KC Heart Rhythm; 2016 Aug; 13(8):1661-6. PubMed ID: 27108939 [TBL] [Abstract][Full Text] [Related]
38. Scar channels in cardiac magnetic resonance to predict appropriate therapies in primary prevention. Sánchez-Somonte P; Quinto L; Garre P; Zaraket F; Alarcón F; Borràs R; Caixal G; Vázquez S; Prat S; Ortiz-Perez JT; Perea RJ; Guasch E; Tolosana JM; Berruezo A; Arbelo E; Sitges M; Mont L; Roca-Luque I Heart Rhythm; 2021 Aug; 18(8):1336-1343. PubMed ID: 33892202 [TBL] [Abstract][Full Text] [Related]
39. Clinical impact of implantable cardioverter-defibrillator in primary prevention of total mortality in non-ischaemic cardiomyopathy: results from a meta-analysis of prospective randomized clinical trials. Romero J; Díaz JC; Grushko M; Quispe R; Briceno D; Avendano R; Golive A; Pina I; Natale A; Garcia MJ; Jorde UP; Di Biase L Europace; 2018 Sep; 20(FI2):f211-f216. PubMed ID: 29161424 [TBL] [Abstract][Full Text] [Related]
40. Ambulatory blood pressure monitoring, 2D-echo and clinical variables relating to cardiac events in ischaemic cardiomyopathy following cardioverter-defibrillator implantation. Antonini L; Pasceri V; Mollica C; Ficili S; Poti G; Aquilani S; Santini M; La Rocca S J Cardiovasc Med (Hagerstown); 2011 May; 12(5):334-9. PubMed ID: 21487343 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]