BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 3011729)

  • 1. Linear programming analysis of VA/Q distributions: limits on central moments.
    Kapitan KS; Wagner PD
    J Appl Physiol (1985); 1986 May; 60(5):1772-81. PubMed ID: 3011729
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of intrapulmonary hematocrit maldistribution on O2, CO2, and inert gas exchange.
    Young IH; Wagner PD
    J Appl Physiol Respir Environ Exerc Physiol; 1979 Feb; 46(2):240-8. PubMed ID: 217855
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Multiple inert gas elimination technique by micropore membrane inlet mass spectrometry--a comparison with reference gas chromatography.
    Kretzschmar M; Schilling T; Vogt A; Rothen HU; Borges JB; Hachenberg T; Larsson A; Baumgardner JE; Hedenstierna G
    J Appl Physiol (1985); 2013 Oct; 115(8):1107-18. PubMed ID: 23869066
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Derivation of VA/Q distribution from blood-gas tensions.
    Kaufman RD; Patterson RW; Lee AS
    Br J Anaesth; 1987 Dec; 59(12):1599-609. PubMed ID: 2827716
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A simple model of VA/Q distribution for analysis of inert gas elimination data.
    Mertens P
    J Appl Physiol Respir Environ Exerc Physiol; 1983 Aug; 55(2):562-8. PubMed ID: 6311779
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Linear programming analysis of VA/Q distributions: average distribution.
    Kapitan KS; Wagner PD
    J Appl Physiol (1985); 1987 Apr; 62(4):1356-62. PubMed ID: 3597211
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Limits on VA/Q distributions from analysis of experimental inert gas elimination.
    Evans JW; Wagner PD
    J Appl Physiol Respir Environ Exerc Physiol; 1977 Jun; 42(6):889-98. PubMed ID: 195926
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Relationships among ventilation-perfusion distribution, multiple inert gas methodology and metabolic blood-gas tensions.
    Lee AS; Patterson RW; Kaufman RD
    Br J Anaesth; 1987 Dec; 59(12):1579-98. PubMed ID: 2827715
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Lobar contribution to VA/Q inequality during constant-flow ventilation.
    Schumacker PT; Solway J; Wood LD; Sznajder JI
    J Appl Physiol (1985); 1988 Nov; 65(5):2132-7. PubMed ID: 3145277
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comparison of continuous and discrete foreign gas VA/Q distributions.
    Teplick R; Snider MT; Gilbert JP
    J Appl Physiol Respir Environ Exerc Physiol; 1980 Oct; 49(4):684-92. PubMed ID: 6254934
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ventilation-perfusion relationships in isolated blood-free perfused rabbit lungs.
    Walmrath D; König R; Ernst C; Brückner H; Grimminger F; Seeger W
    J Appl Physiol (1985); 1992 Jan; 72(1):374-82. PubMed ID: 1311291
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Continuous distributions of ventilation-perfusion ratios in normal subjects breathing air and 100 per cent O2.
    Wagner PD; Laravuso RB; Uhl RR; West JB
    J Clin Invest; 1974 Jul; 54(1):54-68. PubMed ID: 4601004
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A statistical model of the VA/Q distribution.
    Lim LL
    J Appl Physiol (1985); 1990 Jul; 69(1):281-92. PubMed ID: 2168364
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Impact of airway gas exchange on the multiple inert gas elimination technique: theory.
    Anderson JC; Hlastala MP
    Ann Biomed Eng; 2010 Mar; 38(3):1017-30. PubMed ID: 20336837
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ventilation/perfusion ratios measured by multiple inert gas elimination during experimental cardiopulmonary resuscitation.
    Hartmann EK; Duenges B; Boehme S; Szczyrba M; Liu T; Klein KU; Baumgardner JE; Markstaller K; David M
    Acta Anaesthesiol Scand; 2014 Sep; 58(8):1032-9. PubMed ID: 25060587
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Resolution of the multiple inert gas method for estimating VA/Q maldistribution.
    Ratner ER; Wagner PD
    Respir Physiol; 1982 Sep; 49(3):293-313. PubMed ID: 6293027
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Susceptibility of different gases to ventilation-perfusion inequality.
    Wagner PD
    J Appl Physiol Respir Environ Exerc Physiol; 1979 Feb; 46(2):372-86. PubMed ID: 217856
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Continuous distribution of ventilation-perfusion ratios following lung denervation in dogs by means of inert gas elimination method].
    Oku H
    Nihon Kyobu Geka Gakkai Zasshi; 1992 Sep; 40(9):1693-9. PubMed ID: 1328423
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of uneven distribution of VA/Q ratio from data on exchange of respiratory gases.
    Doi K; Niizeki K; Kagawa T; Takahashi K
    Jpn J Physiol; 1986; 36(2):359-78. PubMed ID: 3090328
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ventilation-perfusion inequality in chronic obstructive pulmonary disease.
    Wagner PD; Dantzker DR; Dueck R; Clausen JL; West JB
    J Clin Invest; 1977 Feb; 59(2):203-16. PubMed ID: 833271
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.