These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

240 related articles for article (PubMed ID: 30119371)

  • 1. Timing and probability of crosstalk in a dense CMOS SPAD array in pulsed TOF applications.
    Jahromi S; Kostamovaara J
    Opt Express; 2018 Aug; 26(16):20622-20632. PubMed ID: 30119371
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Design and characterization of a p+/n-well SPAD array in 150nm CMOS process.
    Xu H; Pancheri L; Betta GD; Stoppa D
    Opt Express; 2017 May; 25(11):12765-12778. PubMed ID: 28786630
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Custom single-photon avalanche diode with integrated front-end for parallel photon timing applications.
    Cammi C; Panzeri F; Gulinatti A; Rech I; Ghioni M
    Rev Sci Instrum; 2012 Mar; 83(3):033104. PubMed ID: 22462903
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A first single-photon avalanche diode fabricated in standard SOI CMOS technology with a full characterization of the device.
    Lee MJ; Sun P; Charbon E
    Opt Express; 2015 May; 23(10):13200-9. PubMed ID: 26074572
    [TBL] [Abstract][Full Text] [Related]  

  • 5. High-resolution depth profiling using a range-gated CMOS SPAD quanta image sensor.
    Ren X; Connolly PWR; Halimi A; Altmann Y; McLaughlin S; Gyongy I; Henderson RK; Buller GS
    Opt Express; 2018 Mar; 26(5):5541-5557. PubMed ID: 29529757
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Noise optimization of single-photon avalanche diodes fabricated in 110 nm CMOS image sensor technology.
    Ha WY; Park E; Park B; Chae Y; Choi WY; Lee MJ
    Opt Express; 2022 Apr; 30(9):14958-14965. PubMed ID: 35473228
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High fill-factor miniaturized SPAD arrays with a guard-ring-sharing technique.
    Morimoto K; Charbon E
    Opt Express; 2020 Apr; 28(9):13068-13080. PubMed ID: 32403788
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Avalanche Transients of Thick 0.35 µm CMOS Single-Photon Avalanche Diodes.
    Goll B; Steindl B; Zimmermann H
    Micromachines (Basel); 2020 Sep; 11(9):. PubMed ID: 32961756
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Single-photon avalanche diode fabricated in standard 55 nm bipolar-CMOS-DMOS technology with sub-20 V breakdown voltage.
    Ha WY; Park E; Eom D; Park HS; Chong D; Tan SS; Tng M; Quek E; Bruschini C; Charbon E; Choi WY; Lee MJ
    Opt Express; 2023 Apr; 31(9):13798-13805. PubMed ID: 37157258
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design, characterization and analysis of a 0.35 μm CMOS SPAD.
    Jradi K; Pellion D; Ginhac D
    Sensors (Basel); 2014 Dec; 14(12):22773-84. PubMed ID: 25470491
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High-voltage integrated active quenching circuit for single photon count rate up to 80 Mcounts/s.
    Acconcia G; Rech I; Gulinatti A; Ghioni M
    Opt Express; 2016 Aug; 24(16):17819-31. PubMed ID: 27505749
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Low-noise low-jitter 32-pixels CMOS single-photon avalanche diodes array for single-photon counting from 300 nm to 900 nm.
    Scarcella C; Tosi A; Villa F; Tisa S; Zappa F
    Rev Sci Instrum; 2013 Dec; 84(12):123112. PubMed ID: 24387425
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Multi-Channel Gating Chip in 0.18 µm High-Voltage CMOS for Quantum Applications.
    Ribisch C; Hofbauer M; Kohneh Poushi SS; Zimmer A; Schneider-Hornstein K; Goll B; Zimmermann H
    Sensors (Basel); 2023 Dec; 23(24):. PubMed ID: 38139490
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Photon-Detection-Probability Simulation Method for CMOS Single-Photon Avalanche Diodes.
    Hsieh CA; Tsai CM; Tsui BY; Hsiao BJ; Lin SD
    Sensors (Basel); 2020 Jan; 20(2):. PubMed ID: 31941031
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Towards a Multi-Pixel Photon-to-Digital Converter for Time-Bin Quantum Key Distribution.
    Carrier S; Labrecque-Dias M; Tannous R; Gendron P; Nolet F; Roy N; Rossignol T; Vachon F; Parent S; Jennewein T; Charlebois S; Pratte JF
    Sensors (Basel); 2023 Mar; 23(7):. PubMed ID: 37050435
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fill-factor improvement of Si CMOS single-photon avalanche diode detector arrays by integration of diffractive microlens arrays.
    Intermite G; McCarthy A; Warburton RE; Ren X; Villa F; Lussana R; Waddie AJ; Taghizadeh MR; Tosi A; Zappa F; Buller GS
    Opt Express; 2015 Dec; 23(26):33777-91. PubMed ID: 26832039
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Variable-load quenching circuit for single-photon avalanche diodes.
    Tisa S; Guerrieri F; Zappa F
    Opt Express; 2008 Feb; 16(3):2232-44. PubMed ID: 18542303
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Modeling and Analysis of Capacitive Relaxation Quenching in a Single Photon Avalanche Diode (SPAD) Applied to a CMOS Image Sensor.
    Inoue A; Okino T; Koyama S; Hirose Y
    Sensors (Basel); 2020 May; 20(10):. PubMed ID: 32466348
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Single-photon avalanche diodes in 0.18-μm high-voltage CMOS technology.
    Huang LD; Wu JY; Wang JP; Tsai CM; Huang YH; Wu DR; Lin SD
    Opt Express; 2017 Jun; 25(12):13333-13339. PubMed ID: 28788870
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Architecture and applications of a high resolution gated SPAD image sensor.
    Burri S; Maruyama Y; Michalet X; Regazzoni F; Bruschini C; Charbon E
    Opt Express; 2014 Jul; 22(14):17573-89. PubMed ID: 25090572
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.