401 related articles for article (PubMed ID: 30119975)
1. High-performance liquid chromatographic determination of 2-aminoethylphosphonic acid and 2-amino-3-phosphonopropionic acid in seawater matrix using precolumn fluorescence derivatization with o-phthalaldehyde-ethanethiol.
Wang S; Deng Y; Liu B; Li X; Lin X; Yuan D; Ma J
J Chromatogr A; 2018 Oct; 1571():147-154. PubMed ID: 30119975
[TBL] [Abstract][Full Text] [Related]
2. Simultaneous analysis of amino acids and amines as their o-phthalaldehyde-ethanethiol-9-fluorenylmethyl chloroformate derivatives in cheese by high-performance liquid chromatography.
Korös A; Varga Z; Molnár-Perl I
J Chromatogr A; 2008 Sep; 1203(2):146-52. PubMed ID: 18674769
[TBL] [Abstract][Full Text] [Related]
3. Optimization of a Precolumn OPA Derivatization HPLC Assay for Monitoring of l-Asparagine Depletion in Serum during l-Asparaginase Therapy.
Zhang M; Zhang Y; Ren S; Zhang Z; Wang Y; Song R
J Chromatogr Sci; 2018 Oct; 56(9):794-801. PubMed ID: 29878070
[TBL] [Abstract][Full Text] [Related]
4. The determination of pharmaceutically active thiols using hydrophilic interaction chromatography followed postcolumn derivatization with o-phthaldialdehyde and fluorescence detection.
Douša M
J Pharm Biomed Anal; 2018 Jul; 156():1-7. PubMed ID: 29684906
[TBL] [Abstract][Full Text] [Related]
5. Advances in the o-phthalaldehyde derivatizations. Comeback to the o-phthalaldehyde-ethanethiol reagent.
Hanczkó R; Jámbor A; Perl A; Molnár-Perl I
J Chromatogr A; 2007 Sep; 1163(1-2):25-42. PubMed ID: 17606270
[TBL] [Abstract][Full Text] [Related]
6. A simple method for the determination of glyphosate and aminomethylphosphonic acid in seawater matrix with high performance liquid chromatography and fluorescence detection.
Wang S; Liu B; Yuan D; Ma J
Talanta; 2016 Dec; 161():700-706. PubMed ID: 27769468
[TBL] [Abstract][Full Text] [Related]
7. Determination of boronophenylalanine in biological samples using precolumn o-phthalaldehyde derivatization and reversed-phase high-performance liquid chromatography.
Di Pierro D; Lazzarino G; Pastore FS; Tavazzi B; Del Bolgia F; Amorini AM; Fazzina G; Giuffrè R
Anal Biochem; 2000 Sep; 284(2):301-6. PubMed ID: 10964413
[TBL] [Abstract][Full Text] [Related]
8. Precolumn o-phthalaldehyde-N-acetyl-L-cysteine derivatization followed by RP-HPLC separation and fluorescence detection of sitagliptin enantiomers in rat plasma.
Nageswara Rao R; Sravan B; Ramakrishna K; Saida S; Padiya R
Chirality; 2013 Dec; 25(12):883-9. PubMed ID: 24038334
[TBL] [Abstract][Full Text] [Related]
9. Fluorometric determination of ammonium ion by ion chromatography using postcolumn derivatization with o-phthaldialdehyde.
Kuo CT; Wang PY; Wu CH
J Chromatogr A; 2005 Aug; 1085(1):91-7. PubMed ID: 16106853
[TBL] [Abstract][Full Text] [Related]
10. Determination of d-amphetamine in biological samples using high-performance liquid chromatography after precolumn derivatization with o-phthaldialdehyde and 3-mercaptopropionic acid.
Bowyer JF; Clausing P; Newport GD
J Chromatogr B Biomed Appl; 1995 Apr; 666(2):241-50. PubMed ID: 7633600
[TBL] [Abstract][Full Text] [Related]
11. High-performance liquid chromatography evaluation of the enantiomeric purity of amino acids by means of automated precolumn derivatization with ortho-phthalaldehyde and chiral thiols.
Kühnreich R; Holzgrabe U
Chirality; 2016 Dec; 28(12):795-804. PubMed ID: 27897327
[TBL] [Abstract][Full Text] [Related]
12. Determination of S-nitrosoglutathione in human and rat plasma by high-performance liquid chromatography with fluorescence and ultraviolet absorbance detection after precolumn derivatization with o-phthalaldehyde.
Tsikas D; Sandmann J; Holzberg D; Pantazis P; Raida M; Frölich JC
Anal Biochem; 1999 Aug; 273(1):32-40. PubMed ID: 10452796
[TBL] [Abstract][Full Text] [Related]
13. Determination of theanine and gamma-aminobutyric acid in tea by high performance- liquid chromatography with precolumn derivatization.
Tu Y; Yang X; Zhang S; Zhu Y
Se Pu; 2012 Feb; 30(2):184-9. PubMed ID: 22679834
[TBL] [Abstract][Full Text] [Related]
14. Liquid chromatography method for determination of bivalirudin in human plasma and urine using automated ortho-phthalaldehyde derivatization and fluorescence detection.
Farthing D; Larus T; Fakhry I; Gehr T; Prats J; Sica D
J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Apr; 802(2):355-9. PubMed ID: 15018798
[TBL] [Abstract][Full Text] [Related]
15. Analysis of L-homoarginine in biological samples by HPLC involving precolumn derivatization with o-phthalaldehyde and N-acetyl-L-cysteine.
Hou Y; Jia S; Nawaratna G; Hu S; Dahanayaka S; Bazer FW; Wu G
Amino Acids; 2015 Sep; 47(9):2005-14. PubMed ID: 25820767
[TBL] [Abstract][Full Text] [Related]
16. Behavior and characteristics of biogenic amines, ornithine and lysine derivatized with the o-phthalaldehyde-ethanethiol-fluorenylmethyl chloroformate reagent.
Hanczko R; Korös A; Tóth F; Molnár-Perl I
J Chromatogr A; 2005 Sep; 1087(1-2):210-22. PubMed ID: 16130716
[TBL] [Abstract][Full Text] [Related]
17. [Determination of amino acids by precolumn derivatization with o-phthaldialdehyde (OPA) and reversed-phase high performance liquid chromatography].
Mou D
Se Pu; 1997 Jul; 15(4):319-21. PubMed ID: 15739465
[TBL] [Abstract][Full Text] [Related]
18. [Simultaneous determination of amino acid and monoamine neurotransmitters in serum by high performance liquid chromatography coupled with precolumn derivatization].
Bai J; Wang D; Liu Z; Zhang J; Liu L; Han Y
Se Pu; 2020 Aug; 38(8):923-928. PubMed ID: 34213184
[TBL] [Abstract][Full Text] [Related]
19. Voltammetric determination of taurine in energy drinks after o-phthalaldehyde-ethanethiol derivatization.
Farag AS; Klikarová J; Česlová L; Vytřas K; Sýs M
Talanta; 2019 Sep; 202():486-493. PubMed ID: 31171211
[TBL] [Abstract][Full Text] [Related]
20. Derivatization and chromatographic behavior of the o-phthaldialdehyde amino acid derivatives obtained with various SH-group-containing additives.
Molnár-Perl I
J Chromatogr A; 2001 Apr; 913(1-2):283-302. PubMed ID: 11355824
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]