These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

247 related articles for article (PubMed ID: 30120005)

  • 1. "Horizontal butterfly" technique in repair of radial meniscus tears: A biomechanical study.
    Aşçi M; Balta O; Kurnaz R; Eren MB; Kuyucu YE; Güneş T
    Acta Orthop Traumatol Turc; 2018 Sep; 52(5):392-396. PubMed ID: 30120005
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Novel Repair Method for Radial Tears of the Medial Meniscus: Biomechanical Comparison of Transtibial 2-Tunnel and Double Horizontal Mattress Suture Techniques Under Cyclic Loading.
    Bhatia S; Civitarese DM; Turnbull TL; LaPrade CM; Nitri M; Wijdicks CA; LaPrade RF
    Am J Sports Med; 2016 Mar; 44(3):639-45. PubMed ID: 26646516
    [TBL] [Abstract][Full Text] [Related]  

  • 3. New suture method for radial tears of the meniscus: biomechanical analysis of cross-suture and double horizontal suture techniques using cyclic load testing.
    Matsubara H; Okazaki K; Izawa T; Tashiro Y; Matsuda S; Nishimura T; Nakanishi Y; Kawamura H; Iwamoto Y
    Am J Sports Med; 2012 Feb; 40(2):414-8. PubMed ID: 22016457
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical Comparison of 3 Novel Repair Techniques for Radial Tears of the Medial Meniscus: The 2-Tunnel Transtibial Technique, a "Hybrid" Horizontal and Vertical Mattress Suture Configuration, and a Combined "Hybrid Tunnel" Technique.
    Buckley PS; Kemler BR; Robbins CM; Aman ZS; Storaci HW; Dornan GJ; LaPrade RF
    Am J Sports Med; 2019 Mar; 47(3):651-658. PubMed ID: 30624953
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Strategies for repair of radial tears close to the meniscal rim--biomechanical analysis with a cyclic loading protocol.
    Herbort M; Siam S; Lenschow S; Petersen W; Zantop T
    Am J Sports Med; 2010 Nov; 38(11):2281-7. PubMed ID: 20889985
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The all-inside all-suture technique demonstrated better biomechanical behaviors in meniscus radial tear repair.
    Doig T; Fagan P; Frush T; Lovse L; Chen C; Lemos S
    Knee Surg Sports Traumatol Arthrosc; 2020 Nov; 28(11):3606-3612. PubMed ID: 32514843
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical evaluation of different suture techniques for arthroscopic transtibial pull-out repair of posterior medial meniscus root tears.
    Feucht MJ; Grande E; Brunhuber J; Burgkart R; Imhoff AB; Braun S
    Am J Sports Med; 2013 Dec; 41(12):2784-90. PubMed ID: 24013348
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of serial sectioning and repair of radial tears in the lateral meniscus.
    Ode GE; Van Thiel GS; McArthur SA; Dishkin-Paset J; Leurgans SE; Shewman EF; Wang VM; Cole BJ
    Am J Sports Med; 2012 Aug; 40(8):1863-70. PubMed ID: 22785603
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical comparison of arthroscopic repair constructs for radial tears of the meniscus.
    Branch EA; Milchteim C; Aspey BS; Liu W; Saliman JD; Anz AW
    Am J Sports Med; 2015 Sep; 43(9):2270-6. PubMed ID: 26245325
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Repair of Longitudinal Meniscal Tears by Single or Double Vertical Loop Sutures: In vitro Biomechanical Study under Cyclic Loading.
    Kurnaz R; Aşçı M; Ergün S; Akgün U; Güneş T
    J Knee Surg; 2020 Mar; 33(3):314-318. PubMed ID: 31683351
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Analysis of a new all-inside versus inside-out technique for repairing radial meniscal tears.
    Beamer BS; Masoudi A; Walley KC; Harlow ER; Manoukian OS; Hertz B; Haeussler C; Olson JJ; Deangelis JP; Nazarian A; Ramappa AJ
    Arthroscopy; 2015 Feb; 31(2):293-8. PubMed ID: 25312766
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Several Techniques Exist With Favorable Biomechanical Outcomes in Radial Meniscus Tear Repair-A Systematic Review.
    Oosten J; Yoder R; DiBartola A; Bowler J; Sparks A; Duerr R; Magnussen R; Kaeding C; Flanigan D
    Arthroscopy; 2022 Aug; 38(8):2557-2578.e4. PubMed ID: 35189305
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Arthroscopic meniscal repair with use of the outside-in technique.
    Rodeo SA
    Instr Course Lect; 2000; 49():195-206. PubMed ID: 10829175
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Tibiofemoral Contact Mechanics After Horizontal or Ripstop Suture in Inside-Out and Transtibial Repair for Meniscus Radial Tears in a Porcine Model.
    Zhang HZ; Zhou YF; Li WP; Luo H; Wu JT; Jiang C; Chen Z; Hou JY; Yang R; Song B; Zhang ZZ
    Arthroscopy; 2021 Mar; 37(3):932-940.e2. PubMed ID: 33227321
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Repair of peripheral vertical meniscus lesions in porcine menisci: in vitro biomechanical testing of 3 different meniscus repair devices.
    Lee YH; Nyland J; Burden R; Caborn DN
    Am J Sports Med; 2013 May; 41(5):1074-81. PubMed ID: 23475943
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A simple cinch is superior to a locking loop for meniscus root repair: a human biomechanical comparison of suture constructs in a transtibial pull-out model.
    Krych AJ; Johnson NR; Wu IT; Smith PA; Stuart MJ
    Knee Surg Sports Traumatol Arthrosc; 2018 Aug; 26(8):2239-2244. PubMed ID: 28748490
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Radial Tears of the Lateral Meniscus-Two Novel Repair Techniques: A Biomechanical Study.
    Stender ZC; Cracchiolo AM; Walsh MP; Patterson DP; Wilusz MJ; Lemos SE
    Orthop J Sports Med; 2018 Apr; 6(4):2325967118768086. PubMed ID: 29780840
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The role of suture cutout in the failure of meniscal root repair during the early post-operative period: a biomechanical study.
    Perez-Blanca A; Prado Nóvoa M; Lombardo Torre M; Espejo-Reina A; Ezquerro Juanco F; Espejo-Baena A
    Int Orthop; 2018 Apr; 42(4):811-818. PubMed ID: 29396804
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical consequences of a complete radial tear adjacent to the medial meniscus posterior root attachment site: in situ pull-out repair restores derangement of joint mechanics.
    Padalecki JR; Jansson KS; Smith SD; Dornan GJ; Pierce CM; Wijdicks CA; Laprade RF
    Am J Sports Med; 2014 Mar; 42(3):699-707. PubMed ID: 24585675
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical evaluation of a transtibial pull-out meniscal root repair: challenging the bungee effect.
    Cerminara AJ; LaPrade CM; Smith SD; Ellman MB; Wijdicks CA; LaPrade RF
    Am J Sports Med; 2014 Dec; 42(12):2988-95. PubMed ID: 25239930
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.