BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 30126085)

  • 1. Continuous Monitoring of Respiratory Rate in Emergency Admissions: Evaluation of the RespiraSense™ Sensor in Acute Care Compared to the Industry Standard and Gold Standard.
    Subbe CP; Kinsella S
    Sensors (Basel); 2018 Aug; 18(8):. PubMed ID: 30126085
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Linshom thermodynamic sensor is a reliable alternative to capnography for monitoring respiratory rate.
    Preiss D; Drew BA; Gosnell J; Kodali BS; Philip JH; Urman RD
    J Clin Monit Comput; 2018 Feb; 32(1):133-140. PubMed ID: 28229352
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Respiratory rate monitoring in ICU patients and healthy volunteers using electrical impedance tomography: a validation study.
    Wisse JJ; Flinsenberg MJW; Jonkman AH; Goos TG; Gommers D
    Physiol Meas; 2024 Jun; 45(5):. PubMed ID: 38588677
    [No Abstract]   [Full Text] [Related]  

  • 4. A Comparison of Measurements of Change in Respiratory Status in Spontaneously Breathing Volunteers by the ExSpiron Noninvasive Respiratory Volume Monitor Versus the Capnostream Capnometer.
    Williams GW; George CA; Harvey BC; Freeman JE
    Anesth Analg; 2017 Jan; 124(1):120-126. PubMed ID: 27384980
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of Postoperative Respiratory Monitoring by Acoustic and Transthoracic Impedance Technologies in Pediatric Patients at Risk of Respiratory Depression.
    Patino M; Kalin M; Griffin A; Minhajuddin A; Ding L; Williams T; Ishman S; Mahmoud M; Kurth CD; Szmuk P
    Anesth Analg; 2017 Jun; 124(6):1937-1942. PubMed ID: 28448390
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Multicenter Study Validating Accuracy of a Continuous Respiratory Rate Measurement Derived From Pulse Oximetry: A Comparison With Capnography.
    Bergese SD; Mestek ML; Kelley SD; McIntyre R; Uribe AA; Sethi R; Watson JN; Addison PS
    Anesth Analg; 2017 Apr; 124(4):1153-1159. PubMed ID: 28099286
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A noncontact RF-based respiratory sensor: results of a clinical trial.
    Madsen S; Baczuk J; Thorup K; Barton R; Patwari N; Langell JT
    J Surg Res; 2016 Jun; 203(1):1-5. PubMed ID: 27338527
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy of remote continuous respiratory rate monitoring technologies intended for low care clinical settings: a prospective observational study.
    van Loon K; Peelen LM; van de Vlasakker EC; Kalkman CJ; van Wolfswinkel L; van Zaane B
    Can J Anaesth; 2018 Dec; 65(12):1324-1332. PubMed ID: 30194672
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reliability of wireless monitoring using a wearable patch sensor in high-risk surgical patients at a step-down unit in the Netherlands: a clinical validation study.
    Breteler MJM; Huizinga E; van Loon K; Leenen LPH; Dohmen DAJ; Kalkman CJ; Blokhuis TJ
    BMJ Open; 2018 Feb; 8(2):e020162. PubMed ID: 29487076
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of Nellcor™ PM1000N and Masimo Radical-7
    Kitsiripant C; Fukada T; Iwakiri H; Tsuchiya Y; Ozaki M; Nomura M
    J Anesth; 2017 Oct; 31(5):709-713. PubMed ID: 28730315
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy of acoustic respiration rate monitoring in pediatric patients.
    Patino M; Redford DT; Quigley TW; Mahmoud M; Kurth CD; Szmuk P
    Paediatr Anaesth; 2013 Dec; 23(12):1166-73. PubMed ID: 24033591
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy of respiratory rate monitoring using a non-invasive acoustic method after general anaesthesia.
    Mimoz O; Benard T; Gaucher A; Frasca D; Debaene B
    Br J Anaesth; 2012 May; 108(5):872-5. PubMed ID: 22323525
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of saturation, heart rate, and respiratory rate at forearm using a Nellcor™ forehead SpO
    Harju J; Vehkaoja A; Lindroos V; Kumpulainen P; Liuhanen S; Yli-Hankala A; Oksala N
    J Clin Monit Comput; 2017 Oct; 31(5):1019-1026. PubMed ID: 27752932
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reliability of a wearable wireless patch for continuous remote monitoring of vital signs in patients recovering from major surgery: a clinical validation study from the TRaCINg trial.
    Downey C; Ng S; Jayne D; Wong D
    BMJ Open; 2019 Aug; 9(8):e031150. PubMed ID: 31420399
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of respiratory rate monitoring using a microwave Doppler sensor mounted on the ceiling of an intensive care unit: a prospective observational study.
    Tanaka H; Yokose M; Takaki S; Mihara T; Saigusa Y; Goto T
    J Clin Monit Comput; 2022 Feb; 36(1):71-79. PubMed ID: 34191253
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement accuracy of a microwave doppler sensor beneath the mattress as a continuous respiratory rate monitor: a method comparison study.
    Tanaka H; Yokose M; Takaki S; Mihara T; Saigusa Y; Goto T
    J Clin Monit Comput; 2024 Feb; 38(1):77-88. PubMed ID: 37792139
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Acoustic respiration rate and pulse oximetry-derived respiration rate: a clinical comparison study.
    Eisenberg ME; Givony D; Levin R
    J Clin Monit Comput; 2020 Feb; 34(1):139-146. PubMed ID: 30478523
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Acoustic sensor versus electrocardiographically derived respiratory rate in unstable trauma patients.
    Yang S; Menne A; Hu P; Stansbury L; Gao C; Dorsey N; Chiu W; Shackelford S; Mackenzie C
    J Clin Monit Comput; 2017 Aug; 31(4):765-772. PubMed ID: 27270963
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Camera-based measurement of respiratory rates is reliable.
    Becker C; Achermann S; Rocque M; Kirenko I; Schlack A; Dreher-Hummel T; Zumbrunn T; Bingisser R; Nickel CH
    Eur J Emerg Med; 2018 Dec; 25(6):416-422. PubMed ID: 28574856
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Contactless respiratory and heart rate monitoring: validation of an innovative tool.
    Ben-Ari J; Zimlichman E; Adi N; Sorkine P
    J Med Eng Technol; 2010; 34(7-8):393-8. PubMed ID: 20698739
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.