These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 30134266)

  • 1. Effects of the Screw-Access Hole Diameter on the Biomechanical Behaviors of 4 Types of Cement-Retained Implant Prosthodontic Systems and Their Surrounding Cortical Bones: A 3D Finite Element Analysis.
    Du L; Li Z; Chang X; Rahhal O; Qin B; Wen X; Zhou D
    Implant Dent; 2018 Oct; 27(5):555-563. PubMed ID: 30134266
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: A finite element analysis.
    Bulaqi HA; Mousavi Mashhadi M; Safari H; Samandari MM; Geramipanah F
    J Prosthet Dent; 2015 Jun; 113(6):548-57. PubMed ID: 25794917
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical Evaluation of Different Implant-Abutment Connections, Retention Systems, and Restorative Materials in the Implant-Supported Single Crowns Using 3D Finite Element Analysis.
    Lemos CAA; Verri FR; Noritomi PY; de Souza Batista VE; Cruz RS; de Luna Gomes JM; de Oliveira Limírio JPJ; Pellizzer EP
    J Oral Implantol; 2022 Jun; 48(3):194-201. PubMed ID: 34091686
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Stress distribution in the abutment and retention screw of a single implant supporting a prosthesis with platform switching.
    Alvarez-Arenal A; Segura-Mori L; Gonzalez-Gonzalez I; Gago A
    Int J Oral Maxillofac Implants; 2013; 28(3):e112-21. PubMed ID: 23748329
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Porcelain fracture resistance of screw-retained, cement-retained, and screw-cement-retained implant-supported metal ceramic posterior crowns.
    Al-Omari WM; Shadid R; Abu-Naba'a L; El Masoud B
    J Prosthodont; 2010 Jun; 19(4):263-73. PubMed ID: 20136704
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Stress distribution in the transitional peri-implant bone in a single implant-supported prosthesis with platform-switching under different angulated loads.
    Álvarez-Arenal Á; Segura-Mori L; Gonzalez-Gonzalez I; DeLlanos-Lanchares H; Sanchez-Lasheras F; Ellacuria-Echevarria J
    Odontology; 2017 Jan; 105(1):68-75. PubMed ID: 26943357
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A finite element analysis of two different dental implants: stress distribution in the prosthesis, abutment, implant, and supporting bone.
    Quaresma SE; Cury PR; Sendyk WR; Sendyk C
    J Oral Implantol; 2008; 34(1):1-6. PubMed ID: 18390236
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of abutment screw preload in two implant connection systems: A 3D finite element study.
    Jung WK; Lee WS; Kwon HB
    J Prosthet Dent; 2019 Nov; 122(5):474.e1-474.e8. PubMed ID: 31590980
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effects of prosthesis materials and prosthesis splinting on peri-implant bone stress around implants in poor-quality bone: a numeric analysis.
    Wang TM; Leu LJ; Wang J; Lin LD
    Int J Oral Maxillofac Implants; 2002; 17(2):231-7. PubMed ID: 11958406
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of Occlusal Stress on Implant Abutment Junction and Implant Bone Interface: A Finite Element Analysis Study.
    Mohanty AK; Varghese T; Bhushan P; Mahapatro RK; Kashi AB; Kariyatty P
    J Contemp Dent Pract; 2022 Dec; 23(12):1190-1194. PubMed ID: 37125514
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The influence of various occlusal materials on stresses transferred to implant-supported prostheses and supporting bone: a three-dimensional finite-element study.
    Sevimay M; Usumez A; Eskitascioglu G
    J Biomed Mater Res B Appl Biomater; 2005 Apr; 73(1):140-7. PubMed ID: 15742379
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Stress distribution in resin-based CAD-CAM implant-supported crowns.
    Ausiello P; Di Lauro AE; Tribst JPM; Watts DC
    Dent Mater; 2023 Jan; 39(1):114-122. PubMed ID: 36566152
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Platform switching: biomechanical evaluation using three-dimensional finite element analysis.
    Tabata LF; Rocha EP; Barão VA; Assunção WG
    Int J Oral Maxillofac Implants; 2011; 26(3):482-91. PubMed ID: 21691594
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dental biomechanics of root-analog implants in different bone types.
    Tribst JPM; Dal Piva AMO; Blom EJ; Kleverlaan CJ; Feilzer AJ
    J Prosthet Dent; 2024 May; 131(5):905-915. PubMed ID: 36428106
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of the parafunctional occlusal loading and crown height on stress distribution.
    Torcato LB; Pellizzer EP; Verri FR; Falcón-Antenucci RM; Batista VE; Lopes LF
    Braz Dent J; 2014; 25(6):554-60. PubMed ID: 25590205
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of screw access channel on the fracture rate of lithium disilicate cement-retained implant-supported posterior crowns.
    Khamis MM; Zakaria NH
    J Prosthet Dent; 2022 Apr; 127(4):618-625. PubMed ID: 33309213
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of implant abutment modification on the extrusion of excess cement at the crown-abutment margin for cement-retained implant restorations.
    Wadhwani C; Piñeyro A; Hess T; Zhang H; Chung KH
    Int J Oral Maxillofac Implants; 2011; 26(6):1241-6. PubMed ID: 22167429
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of framework design on fracture resistance of metal-ceramic implant-supported single crowns.
    de Oliveira JL; Martins LM; Sanada J; de Oliveira PC; do Valle AL
    Int J Prosthodont; 2010; 23(4):350-2. PubMed ID: 20617225
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Three-dimensional image correlation analyses for strains generated by cement and screw-retained implant prostheses.
    Clelland NL; Yilmaz B; Seidt JD
    Clin Implant Dent Relat Res; 2013 Apr; 15(2):271-82. PubMed ID: 22171595
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Stress Distribution in Single Dental Implant System: Three-Dimensional Finite Element Analysis Based on an In Vitro Experimental Model.
    Rezende CE; Chase-Diaz M; Costa MD; Albarracin ML; Paschoeto G; Sousa EA; Rubo JH; Borges AF
    J Craniofac Surg; 2015 Oct; 26(7):2196-200. PubMed ID: 26192032
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.