BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

240 related articles for article (PubMed ID: 30135324)

  • 1. Discongruence Index - Simple Indicator to Predict Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement.
    de Agustin JA; Islas F; Jimenez-Quevedo P; Nombela-Franco L; Rueda Liñares A; Mahia P; Marcos-Alberca P; Pozo E; Gomez de Diego JJ; Luaces M; Nuñez-Gil IJ; Garcia-Fernandez MÁ; Fernandez-Ortiz A; Macaya C; Perez de Isla L
    Circ J; 2018 Oct; 82(11):2880-2886. PubMed ID: 30135324
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Incidence, Predictors, and Clinical Impact of Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement in Asian Patients: The OCEAN-TAVI Registry.
    Miyasaka M; Tada N; Taguri M; Kato S; Enta Y; Otomo T; Hata M; Watanabe Y; Naganuma T; Araki M; Yamanaka F; Shirai S; Ueno H; Mizutani K; Tabata M; Higashimori A; Takagi K; Yamamoto M; Hayashida K;
    JACC Cardiovasc Interv; 2018 Apr; 11(8):771-780. PubMed ID: 29673509
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Computed Tomography-Based Indexed Aortic Annulus Size to Predict Prosthesis-Patient Mismatch.
    Head SJ; Reardon MJ; Deeb GM; Van Mieghem NM; Popma JJ; Gleason TG; Williams MR; Radhakrishnan S; Fremes S; Oh JK; Chang Y; Boulware MJ; Kappetein AP
    Circ Cardiovasc Interv; 2019 Apr; 12(4):e007396. PubMed ID: 30929507
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Geometric changes in ventriculoaortic complex after transcatheter aortic valve replacement and its association with post-procedural prosthesis-patient mismatch: an intraprocedural 3D-TEE study.
    Utsunomiya H; Mihara H; Itabashi Y; Kobayashi S; Siegel RJ; Chakravarty T; Jilaihawi H; Makkar RR; Shiota T
    Eur Heart J Cardiovasc Imaging; 2017 Jan; 18(1):1-10. PubMed ID: 27025512
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement.
    Freeman M; Webb JG; Willson AB; Wheeler M; Blanke P; Moss RR; Thompson CR; Munt B; Norgaard BL; Yang TH; Min JK; Poulsen S; Hansson NC; Binder RK; Toggweiler S; Hague C; Wood DA; Pibarot P; Leipsic J
    J Cardiovasc Comput Tomogr; 2013; 7(4):248-55. PubMed ID: 24148778
    [TBL] [Abstract][Full Text] [Related]  

  • 6. CT-Defined Prosthesis-Patient Mismatch Downgrades Frequency and Severity, and Demonstrates No Association With Adverse Outcomes After Transcatheter Aortic Valve Replacement.
    Mooney J; Sellers SL; Blanke P; Pibarot P; Hahn RT; Dvir D; Douglas PS; Weissman NJ; Kodali SK; Thourani VH; Jilaihawi H; Khalique O; Smith CR; Kueh SH; Ohana M; Grover R; Naoum C; Crowley A; Jaber WA; Alu MC; Parvataneni R; Mack M; Webb JG; Leon MB; Leipsic JA
    JACC Cardiovasc Interv; 2017 Aug; 10(15):1578-1587. PubMed ID: 28734891
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Impact of prosthesis-iteration evolution and sizing practice on the incidence of prosthesis-patient mismatch after transcatheter aortic valve replacement.
    Abdelghani M; Allali A; Kaur J; Hemetsberger R; Mehilli J; Neumann FJ; Frerker C; Kurz T; El-Mawardy M; Richardt G; Abdel-Wahab M
    Catheter Cardiovasc Interv; 2019 Apr; 93(5):971-979. PubMed ID: 30467966
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prosthesis-Patient Mismatch After Aortic Valve Replacement in the PARTNER 2 Trial and Registry.
    Ternacle J; Pibarot P; Herrmann HC; Kodali S; Leipsic J; Blanke P; Jaber W; Mack MJ; Clavel MA; Salaun E; Guzzetti E; Annabi MS; Bernier M; Beaudoin J; Khalique OK; Weissman NJ; Douglas P; Bax J; Dahou A; Xu K; Alu M; Rogers E; Leon M; Thourani VH; Abbas AE; Hahn RT
    JACC Cardiovasc Interv; 2021 Jul; 14(13):1466-1477. PubMed ID: 34238557
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of Valve Size on Prosthesis-Patient Mismatch and Aortic Valve Gradient After Transcatheter versus Surgical Aortic Valve Replacement.
    Aalaei-Andabili SH; Lee TC; Waheed N; Bavry AA; Petersen JW; Wayangankar S; Arnaoutakis GJ; David Anderson R; Beaver TM
    Innovations (Phila); 2019 Jun; 14(3):243-250. PubMed ID: 31074313
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prosthesis-patient mismatch after transcatheter aortic valve replacement: prevalence and medium term prognostic impact.
    León Del Pino MDC; Ruíz Ortiz M; Delgado Ortega M; Sánchez Fernández J; Ferreiro Quero C; Durán Jiménez E; Romero Moreno M; Segura Saint-Gerons J; Ojeda Pineda S; Pan Álvarez-Ossorio M; Mesa Rubio D
    Int J Cardiovasc Imaging; 2019 May; 35(5):827-836. PubMed ID: 30661140
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Incidence and sequelae of prosthesis-patient mismatch in transcatheter versus surgical valve replacement in high-risk patients with severe aortic stenosis: a PARTNER trial cohort--a analysis.
    Pibarot P; Weissman NJ; Stewart WJ; Hahn RT; Lindman BR; McAndrew T; Kodali SK; Mack MJ; Thourani VH; Miller DC; Svensson LG; Herrmann HC; Smith CR; Rodés-Cabau J; Webb J; Lim S; Xu K; Hueter I; Douglas PS; Leon MB
    J Am Coll Cardiol; 2014 Sep; 64(13):1323-34. PubMed ID: 25257633
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reclassification of prosthesis-patient mismatch after transcatheter aortic valve replacement using predicted vs. measured indexed effective orifice area.
    Ternacle J; Guimaraes L; Vincent F; Côté N; Côté M; Lachance D; Clavel MA; Abbas AE; Pibarot P; Rodés-Cabau J
    Eur Heart J Cardiovasc Imaging; 2021 Jan; 22(1):11-20. PubMed ID: 32995865
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Imaging for Predicting and Assessing Prosthesis-Patient Mismatch After Aortic Valve Replacement.
    Pibarot P; Magne J; Leipsic J; Côté N; Blanke P; Thourani VH; Hahn R
    JACC Cardiovasc Imaging; 2019 Jan; 12(1):149-162. PubMed ID: 30621987
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prosthesis-patient mismatch defined by cardiac computed tomography versus echocardiography after transcatheter aortic valve replacement.
    Fukui M; Garcia S; Lesser JR; Gössl M; Tang L; Caye D; Newell M; Hashimoto G; Lopes BBC; Stanberry LI; Enriquez-Sarano M; Pibarot P; Hahn R; Sorajja P; Cavalcante JL
    J Cardiovasc Comput Tomogr; 2021; 15(5):403-411. PubMed ID: 33518457
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Outcomes of Redo Transcatheter Aortic Valve Replacement for the Treatment of Postprocedural and Late Occurrence of Paravalvular Regurgitation and Transcatheter Valve Failure.
    Barbanti M; Webb JG; Tamburino C; Van Mieghem NM; Makkar RR; Piazza N; Latib A; Sinning JM; Won-Keun K; Bleiziffer S; Bedogni F; Kapadia S; Tchetche D; Rodés-Cabau J; Fiorina C; Nombela-Franco L; De Marco F; de Jaegere PP; Chakravarty T; Vaquerizo B; Colombo A; Svensson L; Lange R; Nickenig G; Möllmann H; Walther T; Della Rosa F; Elhmidi Y; Dvir D; Brambilla N; Immè S; Sgroi C; Gulino S; Todaro D; Pilato G; Petronio AS; Tamburino C
    Circ Cardiovasc Interv; 2016 Sep; 9(9):. PubMed ID: 27578840
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of predicted effective orifice area in determining incidence of patient-prosthesis mismatch after transcatheter aortic valve replacement.
    Catalano MA; Rutkin B; Koss E; Maurer G; Berg J; Hartman A; Yu PJ
    J Card Surg; 2021 Jan; 36(1):191-196. PubMed ID: 33169868
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Delivery balloon volume positively correlates with the diameter and effective orifice area of implanted SAPIEN 3.
    Nomura T; Miyasaka M; Nakashima M; Saigan M; Inoue A; Enta Y; Toki Y; Ishii K; Sakurai M; Munehisa Y; Ito J; Hata M; Taguri M; Tada N
    J Cardiol; 2022 Sep; 80(3):190-196. PubMed ID: 35469714
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Self-Expanding Transcatheter Aortic Valve Replacement Versus Surgical Valve Replacement in Patients at High Risk for Surgery: A Study of Echocardiographic Change and Risk Prediction.
    Little SH; Oh JK; Gillam L; Sengupta PP; Orsinelli DA; Cavalcante JL; Chang JD; Adams DH; Zorn GL; Pollak AW; Abdelmoneim SS; Reardon MJ; Qiao H; Popma JJ
    Circ Cardiovasc Interv; 2016 Jun; 9(6):. PubMed ID: 27313280
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Predicting patient-prosthesis mismatch by aortic root evaluation before aortic valve replacement.
    Maeda K; Kuratani T; Yoshioka D; Pak K; Shimamura K; Toda K; Sawa Y
    J Thorac Cardiovasc Surg; 2019 Jul; 158(1):61-69.e4. PubMed ID: 30685162
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prosthesis-patient mismatch in high-risk patients with severe aortic stenosis: A randomized trial of a self-expanding prosthesis.
    Zorn GL; Little SH; Tadros P; Deeb GM; Gleason TG; Heiser J; Kleiman NS; Oh JK; Popma JJ; Adams D; Huang J; Reardon MJ
    J Thorac Cardiovasc Surg; 2016 Apr; 151(4):1014-22, 1023.e1-3. PubMed ID: 26614412
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.