These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

404 related articles for article (PubMed ID: 30154064)

  • 1. Instantaneous Wave-Free Ratio for the Assessment of Intermediate Coronary Artery Stenosis in Patients With Severe Aortic Valve Stenosis: Comparison With Myocardial Perfusion Scintigraphy.
    Yamanaka F; Shishido K; Ochiai T; Moriyama N; Yamazaki K; Sugitani A; Tani T; Tobita K; Mizuno S; Tanaka Y; Murakami M; Takahashi S; Yamazaki S; Saito S
    JACC Cardiovasc Interv; 2018 Oct; 11(20):2032-2040. PubMed ID: 30154064
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of left anterior descending artery stenosis of intermediate severity by fractional flow reserve, instantaneous wave-free ratio, and non-invasive coronary flow reserve.
    Meimoun P; Clerc J; Ardourel D; Djou U; Martis S; Botoro T; Elmkies F; Zemir H; Luycx-Bore A; Boulanger J
    Int J Cardiovasc Imaging; 2017 Jul; 33(7):999-1007. PubMed ID: 27752796
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Diagnostic accuracy of a hybrid approach of instantaneous wave-free ratio and fractional flow reserve using high-dose intracoronary adenosine to characterize intermediate coronary lesions: Results of the PALS (Practical Assessment of Lesion Severity) prospective study.
    Rivero F; Cuesta J; Bastante T; Benedicto A; García-Guimaraes M; Fuentes-Ferrer M; Alvarado T; Alfonso F
    Catheter Cardiovasc Interv; 2017 Dec; 90(7):1070-1076. PubMed ID: 28544741
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Head-to-head comparison of basal stenosis resistance index, instantaneous wave-free ratio, and fractional flow reserve: diagnostic accuracy for stenosis-specific myocardial ischaemia.
    van de Hoef TP; Meuwissen M; Escaned J; Sen S; Petraco R; van Lavieren MA; Echavarria-Pinto M; Nolte F; Nijjer S; Chamuleau SA; Voskuil M; van Eck-Smit BL; Verberne HJ; Henriques JP; Koch KT; de Winter RJ; Spaan JA; Siebes M; Tijssen JG; Davies JE; Piek JJ
    EuroIntervention; 2015 Dec; 11(8):914-25. PubMed ID: 25169594
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of the cut-off value for the instantaneous wave-free ratio of patients with aortic valve stenosis.
    Arashi H; Yamaguchi J; Ri T; Tanaka K; Otsuki H; Nakao M; Kamishima K; Jujo K; Minami Y; Ogawa H; Hagiwara N
    Cardiovasc Interv Ther; 2019 Jul; 34(3):269-274. PubMed ID: 30460666
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of Instantaneous Wave-Free Ratio and Fractional Flow Reserve in Severe Aortic Valve Stenosis.
    Jo HH; Kang DY; Lee JM; Lim SM; Park YS; Choi Y; Kim H; Lee J; Ahn JM; Park DW; Park SJ
    Circ Cardiovasc Interv; 2024 May; 17(5):e013237. PubMed ID: 38629298
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Observations from a real-time, iFR-FFR "hybrid approach" in patients with severe aortic stenosis and coronary artery disease undergoing TAVI.
    Scarsini R; Pesarini G; Lunardi M; Piccoli A; Zanetti C; Cantone R; Bellamoli M; Ferrero V; Gottin L; Faggian G; Ribichini F
    Cardiovasc Revasc Med; 2018; 19(3 Pt B):355-359. PubMed ID: 29113864
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prospective Assessment of the Diagnostic Accuracy of Instantaneous Wave-Free Ratio to Assess Coronary Stenosis Relevance: Results of ADVISE II International, Multicenter Study (ADenosine Vasodilator Independent Stenosis Evaluation II).
    Escaned J; Echavarría-Pinto M; Garcia-Garcia HM; van de Hoef TP; de Vries T; Kaul P; Raveendran G; Altman JD; Kurz HI; Brechtken J; Tulli M; Von Birgelen C; Schneider JE; Khashaba AA; Jeremias A; Baucum J; Moreno R; Meuwissen M; Mishkel G; van Geuns RJ; Levite H; Lopez-Palop R; Mayhew M; Serruys PW; Samady H; Piek JJ; Lerman A;
    JACC Cardiovasc Interv; 2015 May; 8(6):824-833. PubMed ID: 25999106
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Instantaneous wave-free ratio as an alternative to fractional flow reserve in assessment of moderate coronary stenoses: A meta-analysis of diagnostic accuracy studies.
    Maini R; Moscona J; Katigbak P; Fernandez C; Sidhu G; Saleh Q; Irimpen A; Samson R; LeJemtel T
    Cardiovasc Revasc Med; 2018; 19(5 Pt B):613-620. PubMed ID: 29371084
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Discordance Between Resting and Hyperemic Indices of Coronary Stenosis Severity: The VERIFY 2 Study (A Comparative Study of Resting Coronary Pressure Gradient, Instantaneous Wave-Free Ratio and Fractional Flow Reserve in an Unselected Population Referred for Invasive Angiography).
    Hennigan B; Oldroyd KG; Berry C; Johnson N; McClure J; McCartney P; McEntegart MB; Eteiba H; Petrie MC; Rocchiccioli P; Good R; Lindsay MM; Hood S; Watkins S
    Circ Cardiovasc Interv; 2016 Nov; 9(11):. PubMed ID: 27834663
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Correlation between intracoronary physiology and myocardial perfusion imaging in patients with severe aortic stenosis.
    Scarsini R; Cantone R; Venturi G; De Maria GL; Variola A; Braggio P; Lunardi M; Pesarini G; Ferdeghini M; Piccoli A; Feola M; Kharbanda RK; Banning AP; Ribichini F
    Int J Cardiol; 2019 Oct; 292():162-165. PubMed ID: 31029497
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Diagnostic Performance of Resting and Hyperemic Invasive Physiological Indices to Define Myocardial Ischemia: Validation With
    Hwang D; Jeon KH; Lee JM; Park J; Kim CH; Tong Y; Zhang J; Bang JI; Suh M; Paeng JC; Na SH; Cheon GJ; Cook CM; Davies JE; Koo BK
    JACC Cardiovasc Interv; 2017 Apr; 10(8):751-760. PubMed ID: 28365268
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Adverse Plaque Characteristics Relate More Strongly With Hyperemic Fractional Flow Reserve and Instantaneous Wave-Free Ratio Than With Resting Instantaneous Wave-Free Ratio.
    Driessen RS; de Waard GA; Stuijfzand WJ; Raijmakers PG; Danad I; Bom MJ; Min JK; Leipsic JA; Ahmadi A; van de Ven PM; Knuuti J; van Rossum AC; Davies JE; van Royen N; Narula J; Knaapen P
    JACC Cardiovasc Imaging; 2020 Mar; 13(3):746-756. PubMed ID: 31422133
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Discordance between fractional flow reserve and instantaneous wave-free ratio in patients with severe aortic stenosis: A retrospective cohort study.
    Yamanaka F; Shishido K; Yokota S; Moriyama N; Ochiai T; Yamada T; Hayashi T; Miyashita H; Yokoyama H; Yamanaga K; Tabata N; Yamaguchi M; Yamagishi T; Matsumoto T; Tobita K; Mizuno S; Tanaka Y; Murakami M; Takahashi S; Saito S; Tsujita K
    J Cardiol; 2023 Feb; 81(2):138-143. PubMed ID: 36057484
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fractional Flow Reserve and Instantaneous Wave-Free Ratio for Nonculprit Stenosis in Patients With Acute Myocardial Infarction.
    Choi KH; Lee JM; Kim HK; Kim J; Park J; Hwang D; Rhee TM; Park TK; Yang JH; Song YB; Shin ES; Nam CW; Doh JH; Hahn JY; Choi JH; Choi SH; Koo BK; Gwon HC
    JACC Cardiovasc Interv; 2018 Sep; 11(18):1848-1858. PubMed ID: 30236358
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Physiological and Clinical Assessment of Resting Physiological Indexes.
    Lee JM; Choi KH; Park J; Hwang D; Rhee TM; Kim J; Park J; Kim HY; Jung HW; Cho YK; Yoon HJ; Song YB; Hahn JY; Nam CW; Shin ES; Doh JH; Hur SH; Koo BK
    Circulation; 2019 Feb; 139(7):889-900. PubMed ID: 30586749
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Diagnostic Performance of the Instantaneous Wave-Free Ratio: Comparison With Fractional Flow Reserve.
    De Rosa S; Polimeni A; Petraco R; Davies JE; Indolfi C
    Circ Cardiovasc Interv; 2018 Jan; 11(1):e004613. PubMed ID: 29326150
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Revisiting the Optimal Fractional Flow Reserve and Instantaneous Wave-Free Ratio Thresholds for Predicting the Physiological Significance of Coronary Artery Disease.
    Modi BN; Rahman H; Kaier T; Ryan M; Williams R; Briceno N; Ellis H; Pavlidis A; Redwood S; Clapp B; Perera D
    Circ Cardiovasc Interv; 2018 Dec; 11(12):e007041. PubMed ID: 30562079
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Efficacy of pressure parameters obtained during contrast medium-induced submaximal hyperemia in the functional assessment of intermediate coronary stenosis in comparison with instantaneous wave-free ratio.
    Kanaji Y; Murai T; Lee T; Matsuda J; Usui E; Araki M; Niida T; Ichijyo S; Hamaya R; Yonetsu T; Kimura S; Kakuta T
    Int J Cardiol; 2016 Apr; 208():128-36. PubMed ID: 26851699
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The reasons why fractional flow reserve and instantaneous wave-free ratio are similar using wave separation analysis.
    Min S; Kang G; Paeng DG; Choi JH
    BMC Cardiovasc Disord; 2021 Jan; 21(1):48. PubMed ID: 33494709
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.