These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 30156575)

  • 1. Estimating the Accuracy of Dobutamine Stress Echocardiography and Single-Photon Emission Computed Tomography among Patients Undergoing Noncardiac Surgery.
    Pappas MA; Auerbach AD
    J Hosp Med; 2018 Nov; 13(11):783-786. PubMed ID: 30156575
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of coronary artery disease in women by dobutamine stress echocardiography: comparison with stress thallium-201 single-photon emission computed tomography and exercise electrocardiography.
    Ho YL; Wu CC; Huang PJ; Lin LC; Chieng PU; Chen WJ; Chen MF; Lee YT
    Am Heart J; 1998 Apr; 135(4):655-62. PubMed ID: 9539482
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Incremental diagnostic value of dobutamine stress echocardiography and dobutamine scintigraphy (technetium 99m-labeled sestamibi single-photon emission computed tomography) for assessment of presence and extent of coronary artery disease.
    Di Bello V; Bellina CR; Gori E; Molea N; Talarico L; Boni G; Magagnini E; Matteucci F; Giorgi D; Lazzeri E; Bertini A; Romano MF; Bianchi R; Giusti C
    J Nucl Cardiol; 1996; 3(3):212-20. PubMed ID: 8805741
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comprehensive dobutamine stress CMR versus echocardiography in LBBB and suspected coronary artery disease.
    Mordi I; Stanton T; Carrick D; McClure J; Oldroyd K; Berry C; Tzemos N
    JACC Cardiovasc Imaging; 2014 May; 7(5):490-8. PubMed ID: 24726256
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dobutamine stress echocardiography compared with exercise thallium-201 single-photon emission computed tomography in detecting coronary artery disease-effect of exercise level on accuracy.
    Ho YL; Wu CC; Huang PJ; Tseng WK; Lin LC; Chieng PU; Chen MF; Lee YT
    Cardiology; 1997; 88(4):379-85. PubMed ID: 9197434
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of thallium-201 exercise SPECT and dobutamine stress echocardiography for diagnosis of coronary artery disease in patients with left bundle branch block.
    Tandoğan I; Yetkin E; Yanik A; Ulusoy FV; Temizhan A; Cehreli S; Sasmaz A
    Int J Cardiovasc Imaging; 2001 Oct; 17(5):339-45. PubMed ID: 12025947
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy of dobutamine technetium 99m sestamibi SPECT imaging for the diagnosis of single-vessel coronary artery disease: comparison with echocardiography.
    Elhendy A; van Domburg RT; Bax JJ; Poldermans D; Sozzi FB; Roelandt JR
    Am Heart J; 2000 Feb; 139(2 Pt 1):224-30. PubMed ID: 10650294
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Head-to-head comparison of prognostic accuracy in patients undergoing noncardiac surgery of dobutamine stress echocardiography versus computed tomography coronary angiography (PANDA trial): A prospective observational study.
    Ahn JH; Jeong YH; Park Y; Kwak CH; Jang JY; Hwang JY; Hwang SJ; Koh JS; Kim KH; Kang MG; Park JR
    J Cardiovasc Comput Tomogr; 2020; 14(6):471-477. PubMed ID: 32057706
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Usefulness of pulse-wave Doppler tissue sampling and dobutamine stress echocardiography for identification of false positive inferior wall defects in SPECT.
    Altinmakas S; Dağdeviren B; Türkmen M; Gürsürer M; Say B; Tezel T; Ersek B
    Jpn Heart J; 2000 Mar; 41(2):141-52. PubMed ID: 10850530
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dobutamine-atropine stress echocardiography and dipyridamole sestamibi scintigraphy for the detection of coronary artery disease: limitations and concordance.
    Smart SC; Bhatia A; Hellman R; Stoiber T; Krasnow A; Collier BD; Sagar KB
    J Am Coll Cardiol; 2000 Oct; 36(4):1265-73. PubMed ID: 11028482
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mechanisms of regional wall motion abnormalities in contrast-enhanced dobutamine stress echocardiography.
    Heinicke N; Benesch B; Kaiser T; Debl K; Segmüller M; Schönberger J; Marienhagen J; Eilles C; Riegger GA; Holmer S; Luchner A
    Clin Res Cardiol; 2006 Dec; 95(12):650-6. PubMed ID: 16998740
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cardiac complications in noncardiac surgery: value of dobutamine stress echocardiography versus dipyridamole thallium imaging.
    Kontos MC; Akosah KO; Brath LK; Funai JT; Mohanty PK
    J Cardiothorac Vasc Anesth; 1996 Apr; 10(3):329-35. PubMed ID: 8725412
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dobutamine stress echocardiography versus quantitative technetium-99m sestamibi SPECT for detecting residual stenosis and multivessel disease after myocardial infarction.
    Lancellotti P; Benoit T; Rigo P; Pierard LA
    Heart; 2001 Nov; 86(5):510-5. PubMed ID: 11602542
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of exercise electrocardiography, technetium-99m sestamibi single photon emission computed tomography, and dobutamine and dipyridamole echocardiography for detection of coronary artery disease in hypertensive women.
    Lu C; Lu F; Fragasso G; Dabrowski P; Di Bello V; Chierchia SL; Gianolli L; Marzilli M; Balbarini A
    Am J Cardiol; 2010 May; 105(9):1254-60. PubMed ID: 20403475
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of dobutamine stress echocardiography and 99m-technetium sestamibi SPECT myocardial perfusion scintigraphy for predicting extent of coronary artery disease in patients with healed myocardial infarction.
    Elhendy A; Geleijnse ML; Roelandt JR; van Domburg RT; Ten Cate FJ; Nierop PR; Bax JJ; El-Refaee M; Ibrahim MM; El-Said GM; Fioretti PM
    Am J Cardiol; 1997 Jan; 79(1):7-12. PubMed ID: 9024727
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Noninvasive diagnosis of coronary artery stenosis in women with limited exercise capacity: comparison of dobutamine stress echocardiography and 99mTc sestamibi single-photon emission CT.
    Elhendy A; van Domburg RT; Bax JJ; Nierop PR; Geleijnse ML; Ibrahim MM; Roelandt JR
    Chest; 1998 Oct; 114(4):1097-104. PubMed ID: 9792583
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biphasic response to dobutamine predicts improvement of left ventricular dysfunction after revascularization: correlation with positron emission and rest-redistribution 201Tl tomographies.
    Hernandez-Pampaloni M; Peral V; Carreras JL; Sanchez-Harguindey L; Vilacosta I
    Int J Cardiovasc Imaging; 2003 Dec; 19(6):519-28. PubMed ID: 14690191
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of exercise stress testing with simultaneous dobutamine stress echocardiography and technetium-99m isonitrile single-photon emission computerized tomography for diagnosis of coronary artery disease.
    Kisacik HL; Ozdemir K; Altinyay E; Oğuzhan A; Kural T; Kir M; Kütük E; Göksel S
    Eur Heart J; 1996 Jan; 17(1):113-9. PubMed ID: 8682117
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Detecting viable myocardium and predicting functional improvement: comparisons of positron emission tomography, rest-redistribution thallium-201 single-photon emission computed tomography (SPECT), exercise thallium-201 reinjection SPECT, I-123 BMIPP SPECT and dobutamine stress echocardiography.
    Tani T; Teragaki M; Watanabe H; Muro T; Yamagishi H; Akioka K; Yoshiyama M; Takeuchi K; Yoshikawa J
    Circ J; 2004 Oct; 68(10):950-7. PubMed ID: 15459470
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dobutamine stress thallium-201 single-photon emission tomography versus echocardiography for evaluation of the extent and location of coronary artery disease late after myocardial infarction.
    Elhendy A; Bax JJ; van Domburg RT; Valkema R; Cornel JH; Reijs AE; Krenning EP; Roelandt JR
    Eur J Nucl Med; 1999 May; 26(5):467-73. PubMed ID: 10382089
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.