458 related articles for article (PubMed ID: 30170672)
1. Implications of Transcatheter Heart Valve Selection on Early and Late Pacemaker Rate and on Length of Stay.
Sathananthan J; Ding L; Yu M; Catlin B; Chan A; Charania J; Cheung A; Cook R; Murdoch DJ; Della Siega A; Latham T; Lauck S; Polderman J; Robinson SD; Virani S; Wong D; Wood D; Ye J; Webb JG
Can J Cardiol; 2018 Sep; 34(9):1165-1173. PubMed ID: 30170672
[TBL] [Abstract][Full Text] [Related]
2. Clinical outcomes of self-expandable vs. balloon-expandable TAVI for severe aortic stenosis.
Tham JLM; Adams H; Paleri S; Wright C; Dimitriou J; Newcomb A; MacIsaac AI; Whitbourn RJ; Palmer SC
Acta Cardiol; 2020 Jun; 75(3):218-225. PubMed ID: 30931804
[No Abstract] [Full Text] [Related]
3. Infective Endocarditis Following Transcatheter Aortic Valve Replacement: Comparison of Balloon- Versus Self-Expandable Valves.
Regueiro A; Linke A; Latib A; Ihlemann N; Urena M; Walther T; Husser O; Herrmann C; Nombela-Franco L; Cheema A; Le Breton H; Stortecky S; Kapadia S; Bartorelli L; Sinning JM; Amat-Santos I; Munoz-Garcia J; Lerakis S; Gutíerrez-Ibanes E; Abdel-Wahab M; Tchetche D; Testa L; Eltchaninoff H; Livi U; Castillo JC; Jilaihawi H; Webb G; Barbanti M; Kodali S; de Brito Jr S; Ribeiro B; Miceli A; Fiorina C; Actis Dato GM; Rosato F; Serra V; Masson JB; Wijeysundera C; Mangione A; Ferreira MC; Lima C; Carvalho A; Abizaid A; Marino A; Esteves V; Andrea C.M.; Messika-Zeitoun D; Himbert D; Kim WK; Pellegrini C; Auffret V; Nietlispach F; Pilgrim T; Durand E; Lisko J; Makkar R; Lemos P; Leon B; Puri R; San Roman A; Vahanian A; Søndergaard L; Mangner N; Rodés-Cabau J
Circ Cardiovasc Interv; 2019 Nov; 12(11):e007938. PubMed ID: 31694412
[TBL] [Abstract][Full Text] [Related]
4. Permanent pacemaker implantation following transcatheter aortic valve implantation using self-expandable, balloon-expandable, or mechanically expandable devices: a network meta-analysis.
Ravaux JM; Di Mauro M; Vernooy K; Kats S; Mariani S; Ronco D; Actis Dato G; Simons J; Hof AWV; Maessen JG; Lorusso R
Europace; 2021 Dec; 23(12):1998-2009. PubMed ID: 34379760
[TBL] [Abstract][Full Text] [Related]
5. Impact of device-host interaction on paravalvular aortic regurgitation with different transcatheter heart valves.
Rodríguez-Olivares R; El Faquir N; Rahhab Z; van Gils L; Ren B; Sakhi R; Geleijnse ML; van Domburg R; de Jaegere PPT; Zamorano Gómez JL; Van Mieghem NM
Cardiovasc Revasc Med; 2019 Feb; 20(2):126-132. PubMed ID: 29779973
[TBL] [Abstract][Full Text] [Related]
6. Edwards SAPIEN Versus Medtronic Aortic Bioprosthesis in Women Undergoing Transcatheter Aortic Valve Implantation (from the Win-TAVI Registry).
Giannini C; Petronio AS; Mehilli J; Sartori S; Chandrasekhar J; Faggioni M; Lefèvre T; Presbitero P; Capranzano P; Tchetche D; Iadanza A; Sardella G; Van Mieghem NM; Meliga E; Dumonteil N; Fraccaro C; Trabattoni D; Mikhail GW; Ferrer MC; Naber C; Kievit P; Sorrentino S; Morice MC; Chieffo A; Mehran R;
Am J Cardiol; 2020 Feb; 125(3):441-448. PubMed ID: 31813530
[TBL] [Abstract][Full Text] [Related]
7. Meta-analysis Comparing Outcomes of Self-Expanding Versus Balloon-Expandable Valves for Transcatheter Aortic Valve Implantation.
Elgendy IY; Gad MM; Mahmoud AN; Dvir D; Kapadia SR; Alfonso F; Capodanno D
Am J Cardiol; 2020 Aug; 128():202-209. PubMed ID: 32534734
[TBL] [Abstract][Full Text] [Related]
8. Effect of Mechanically Expanded vs Self-Expanding Transcatheter Aortic Valve Replacement on Mortality and Major Adverse Clinical Events in High-Risk Patients With Aortic Stenosis: The REPRISE III Randomized Clinical Trial.
Feldman TE; Reardon MJ; Rajagopal V; Makkar RR; Bajwa TK; Kleiman NS; Linke A; Kereiakes DJ; Waksman R; Thourani VH; Stoler RC; Mishkel GJ; Rizik DG; Iyer VS; Gleason TG; Tchétché D; Rovin JD; Buchbinder M; Meredith IT; Götberg M; Bjursten H; Meduri C; Salinger MH; Allocco DJ; Dawkins KD
JAMA; 2018 Jan; 319(1):27-37. PubMed ID: 29297076
[TBL] [Abstract][Full Text] [Related]
9. Three-year clinical outcomes after transcatheter aortic valve implantation in patients with bicuspid aortic disease: Comparison between self-expanding and balloon-expandable valves.
Boiago M; Bellamoli M; De Biase C; Beneduce A; Alonso LG; Laforgia P; Feliachi S; Oliva OA; Dumonteil N; Tchétché D
Catheter Cardiovasc Interv; 2024 May; 103(6):1004-1014. PubMed ID: 38577939
[TBL] [Abstract][Full Text] [Related]
10. Comparison of outcomes of self-expanding versus balloon-expandable valves for transcatheter aortic valve replacement: a meta-analysis of randomized and propensity-matched studies.
Wang B; Mei Z; Ge X; Li Y; Zhou Q; Meng X; An G
BMC Cardiovasc Disord; 2023 Jul; 23(1):382. PubMed ID: 37525092
[TBL] [Abstract][Full Text] [Related]
11. Comparative meta-analysis of balloon-expandable and self-expandable valves for transcatheter aortic valve replacement.
Agarwal S; Parashar A; Kumbhani DJ; Svensson LG; Krishnaswamy A; Tuzcu EM; Kapadia SR
Int J Cardiol; 2015 Oct; 197():87-97. PubMed ID: 26117654
[TBL] [Abstract][Full Text] [Related]
12. Early and midterm outcomes of transcatheter aortic-valve replacement with balloon-expandable versus self-expanding valves: A meta-analysis.
Zhang XL; Wei ZH; Wang HW; Xu W; Wang Y; Xu B
J Cardiol; 2022 Sep; 80(3):204-210. PubMed ID: 35599108
[TBL] [Abstract][Full Text] [Related]
13. Predictors and clinical outcomes of permanent pacemaker implantation after transcatheter aortic valve replacement: the PARTNER (Placement of AoRtic TraNscathetER Valves) trial and registry.
Nazif TM; Dizon JM; Hahn RT; Xu K; Babaliaros V; Douglas PS; El-Chami MF; Herrmann HC; Mack M; Makkar RR; Miller DC; Pichard A; Tuzcu EM; Szeto WY; Webb JG; Moses JW; Smith CR; Williams MR; Leon MB; Kodali SK;
JACC Cardiovasc Interv; 2015 Jan; 8(1 Pt A):60-9. PubMed ID: 25616819
[TBL] [Abstract][Full Text] [Related]
14. Contemporary transcatheter aortic valve replacement with third-generation balloon-expandable versus self-expanding devices.
Rogers T; Steinvil A; Buchanan K; Alraies MC; Koifman E; Gai J; Torguson R; Okubagzi P; Ben-Dor I; Pichard A; Satler L; Waksman R
J Interv Cardiol; 2017 Aug; 30(4):356-361. PubMed ID: 28493389
[TBL] [Abstract][Full Text] [Related]
15. Center Valve Preference and Outcomes of Transcatheter Aortic Valve Replacement: Insights From the AMTRAC Registry.
Witberg G; Landes U; Talmor-Barkan Y; Richter I; Barbanti M; Valvo R; De Backer O; Ooms JF; Islas F; Marroquin L; Sedaghat A; Sugiura A; Masiero G; Armario X; Fiorina C; Arzamendi D; Santos-Martinez S; Fernández-Vázquez F; Baz JA; Steblovnik K; Mauri V; Adam M; Merdler I; Hein M; Ruile P; Codner P; Grasso C; Branca L; Estévez-Loureiro R; Benito-González T; Amat-Santos IJ; Mylotte D; Bunc M; Tarantini G; Nombela-Franco L; Søndergaard L; Van Mieghem NM; Finkelstein A; Kornowski R
JACC Cardiovasc Interv; 2022 Jun; 15(12):1266-1274. PubMed ID: 35738747
[TBL] [Abstract][Full Text] [Related]
16. Differences in blood flow dynamics between balloon- and self-expandable valves in patients with aortic stenosis undergoing transcatheter aortic valve replacement.
Takahashi Y; Kamiya K; Nagai T; Tsuneta S; Oyama-Manabe N; Hamaya T; Kazui S; Yasui Y; Saiin K; Naito S; Mizuguchi Y; Takenaka S; Tada A; Ishizaka S; Kobayashi Y; Omote K; Sato T; Shingu Y; Kudo K; Wakasa S; Anzai T
J Cardiovasc Magn Reson; 2023 Oct; 25(1):60. PubMed ID: 37880721
[TBL] [Abstract][Full Text] [Related]
17. Impact of membranous septum length on pacemaker need with different transcatheter aortic valve replacement systems: The INTERSECT registry.
Hokken TW; Muhemin M; Okuno T; Veulemans V; Lopes BB; Beneduce A; Vittorio R; Ooms JF; Adrichem R; Neleman T; Kardys I; Daemen J; Chieffo A; Montorfano M; Cavalcante J; Zeus T; Pilgrim T; Toggweiler S; Van Mieghem NM
J Cardiovasc Comput Tomogr; 2022; 16(6):524-530. PubMed ID: 35872136
[TBL] [Abstract][Full Text] [Related]
18. Different dynamics of new-onset electrocardiographic changes after balloon- and self-expandable transcatheter aortic valve replacement: Implications for prolonged heart rhythm monitoring.
Coeman M; Kayaert P; Philipsen T; Calle S; Gheeraert P; Gevaert S; Czapla J; Timmers L; Van Heuverswyn F; De Pooter J
J Electrocardiol; 2020; 59():68-73. PubMed ID: 32007908
[TBL] [Abstract][Full Text] [Related]
19. Transcatheter heart valve selection in patients with low ejection fraction and aortic stenosis.
Mustafa A; Kliger C; Pirelli L; Kodra A; Wang D; Singh P; Arnone P; Patel A; Liu S; Mihelis E; Koss E; Wilson S; Maniatis G; Imam M; Gandotra P; Kalimi R; Supariwala A; Meraj P; Rutkin B; Hartman AR; Scheinerman SJ; Basman C
J Card Surg; 2022 Dec; 37(12):4937-4943. PubMed ID: 36378870
[TBL] [Abstract][Full Text] [Related]
20. Predictors and 5-Year Clinical Outcomes of Pacemaker After TAVR: Analysis From the PARTNER 2 SAPIEN 3 Registries.
Chen S; Dizon JM; Hahn RT; Pibarot P; George I; Zhao Y; Blanke P; Kapadia S; Babaliaros V; Szeto WY; Makkar R; Thourani VH; Webb JG; Mack MJ; Leon MB; Kodali S; Nazif TM
JACC Cardiovasc Interv; 2024 Jun; 17(11):1325-1336. PubMed ID: 38866455
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]