These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

200 related articles for article (PubMed ID: 30170828)

  • 1. A randomized trial comparing two stent sizing strategies in coronary bifurcation treatment with bioresorbable vascular scaffolds - The Absorb Bifurcation Coronary (ABC) trial.
    Rampat R; Mayo T; Hildick-Smith D; Cockburn J
    Cardiovasc Revasc Med; 2019 Jan; 20(1):43-49. PubMed ID: 30170828
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Coronary artery perforation after bioresorbable scaffold implantation treated with a new generation covered stent-OCT insights.
    Chen D; Gadeley R; Wang A; Jepson N
    BMC Cardiovasc Disord; 2022 Feb; 22(1):66. PubMed ID: 35196989
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Treatment of coronary bifurcation lesions with the Absorb bioresorbable vascular scaffold in combination with the Tryton dedicated coronary bifurcation stent: evaluation using two- and three-dimensional optical coherence tomography.
    Grundeken MJ; Hassell ME; Kraak RP; de Bruin DM; Koch KT; Henriques JP; van Leeuwen TG; Tijssen JG; Piek JJ; de Winter RJ; Wykrzykowska JJ
    EuroIntervention; 2015 Dec; 11(8):877-84. PubMed ID: 25169592
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Incidence and short-term clinical outcomes of small side branch occlusion after implantation of an everolimus-eluting bioresorbable vascular scaffold: an interim report of 435 patients in the ABSORB-EXTEND single-arm trial in comparison with an everolimus-eluting metallic stent in the SPIRIT first and II trials.
    Muramatsu T; Onuma Y; García-García HM; Farooq V; Bourantas CV; Morel MA; Li X; Veldhof S; Bartorelli A; Whitbourn R; Abizaid A; Serruys PW;
    JACC Cardiovasc Interv; 2013 Mar; 6(3):247-57. PubMed ID: 23517836
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The absorb bioresorbable vascular scaffold in coronary bifurcations: insights from bench testing.
    Džavík V; Colombo A
    JACC Cardiovasc Interv; 2014 Jan; 7(1):81-8. PubMed ID: 24332424
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The relationship of pre-procedural Dmax based sizing to lesion level outcomes in Absorb BVS and Xience EES treated patients in the AIDA trial.
    Tijssen RYG; Kerkmeijer LSM; Katagiri Y; Kraak RP; Takahashi K; Kogame N; Chichareon P; Modolo R; Asano T; Nassif M; Kalkman DN; Sotomi Y; Collet C; Hofma SH; van der Schaaf RJ; Arkenbout EK; Weevers APJD; Beijk MAM; Piek JJ; Tijssen JGP; Henriques JP; de Winter RJ; Onuma Y; Serruys PW; Wykrzykowska JJ
    Int J Cardiovasc Imaging; 2019 Jul; 35(7):1189-1198. PubMed ID: 30911857
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optical Coherence Tomography for Coronary Bioresorbable Vascular Scaffold Implantation: A Randomized Controlled Trial.
    Lee SY; Kang DY; Hong SJ; Ahn JM; Ahn CM; Park DW; Kim JS; Kim BK; Ko YG; Choi D; Jang Y; Park SJ; Hong MK
    Circ Cardiovasc Interv; 2020 Jan; 13(1):e008383. PubMed ID: 32525410
    [TBL] [Abstract][Full Text] [Related]  

  • 8. ABSORB biodegradable stents versus second-generation metal stents: a comparison study of 100 complex lesions treated under OCT guidance.
    Mattesini A; Secco GG; Dall'Ara G; Ghione M; Rama-Merchan JC; Lupi A; Viceconte N; Lindsay AC; De Silva R; Foin N; Naganuma T; Valente S; Colombo A; Di Mario C
    JACC Cardiovasc Interv; 2014 Jul; 7(7):741-50. PubMed ID: 25060016
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of Technique on Outcomes Following Bioresorbable Vascular Scaffold Implantation: Analysis From the ABSORB Trials.
    Stone GW; Abizaid A; Onuma Y; Seth A; Gao R; Ormiston J; Kimura T; Chevalier B; Ben-Yehuda O; Dressler O; McAndrew T; Ellis SG; Kereiakes DJ; Serruys PW
    J Am Coll Cardiol; 2017 Dec; 70(23):2863-2874. PubMed ID: 29100704
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An observational study of clinical outcomes of everolimus-eluting bioresorbable scaffolds comparing the procedural use of optical coherence tomography against angiography alone.
    Hamshere S; Byrne A; Guttmann O; Rees P; Bourantas C; Weerakody R; Wragg A; Knight C; Mathur A; Jones DA
    Coron Artery Dis; 2018 Sep; 29(6):482-488. PubMed ID: 29642228
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bioresorbable vascular scaffolds for the treatment of coronary artery disease: what have we learned from randomized-controlled clinical trials?
    Rizik DG; Hermiller JB; Simonton CA; Klassen KJ; Kereiakes DJ
    Coron Artery Dis; 2017 Jan; 28(1):77-89. PubMed ID: 27561169
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mid-term clinical outcomes of ABSORB bioresorbable vascular scaffold versus everolimus-eluting stent for coronary bifurcation lesions.
    Naganuma T; Kawamoto H; Panoulas VF; Latib A; Tanaka A; Mitomo S; Ruparelia N; Jabbour RJ; Chieffo A; Carlino M; Montorfano M; Colombo A
    Int J Cardiol; 2017 Nov; 246():26-31. PubMed ID: 28867010
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Economic Outcomes of Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Stents in Patients Undergoing Percutaneous Coronary Intervention: 1-Year Results From the ABSORB III Trial.
    Baron SJ; Lei Y; Chinnakondepalli K; Vilain K; Magnuson EA; Kereiakes DJ; Ellis SG; Stone GW; Cohen DJ;
    JACC Cardiovasc Interv; 2017 Apr; 10(8):774-782. PubMed ID: 28427593
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Sequential Proximal Optimizing Technique in Provisional Bifurcation Stenting With Everolimus-Eluting Bioresorbable Vascular Scaffold: Fractal Coronary Bifurcation Bench for Comparative Test Between Absorb and XIENCE Xpedition.
    Derimay F; Souteyrand G; Motreff P; Guerin P; Pilet P; Ohayon J; Darremont O; Rioufol G; Finet G
    JACC Cardiovasc Interv; 2016 Jul; 9(13):1397-406. PubMed ID: 27388830
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bioresorbable vascular scaffold use for coronary bifurcation lesions: A substudy from GHOST EU registry.
    Naganuma T; Colombo A; Lesiak M; Capodanno D; Gori T; Nef H; Caramanno G; Naber C; Di Mario C; Ruparelia N; Capranzano P; Wiebe J; Araszkiewicz A; Geraci S; Kawamoto H; Pyxaras S; Mattesini A; Münzel T; Tamburino C; Latib A
    Catheter Cardiovasc Interv; 2017 Jan; 89(1):47-56. PubMed ID: 27414021
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Applicability and procedural success rate of bioresorbable -vascular scaffolds for percutaneous coronary intervention in an all-comer cohort of 383 consecutive patients.
    Schlundt C; Achenbach S; Felten F; Roether J; Marwan M; Nef H; Ludwig J; Tröbs M
    Acta Cardiol; 2017 Aug; 72(4):425-432. PubMed ID: 28705057
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fate of post-procedural malapposition of everolimus-eluting polymeric bioresorbable scaffold and everolimus-eluting cobalt chromium metallic stent in human coronary arteries: sequential assessment with optical coherence tomography in ABSORB Japan trial.
    Sotomi Y; Onuma Y; Dijkstra J; Miyazaki Y; Kozuma K; Tanabe K; Popma JJ; de Winter RJ; Serruys PW; Kimura T
    Eur Heart J Cardiovasc Imaging; 2018 Jan; 19(1):59-66. PubMed ID: 28158421
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Absorb bioresorbable vascular scaffold vs. everolimus-eluting metallic stent in small vessel disease: A propensity matched analysis of COMPARE II, RAI, and MAASSTAD-ABSORB studies.
    Tarantini G; Masiero G; Barioli A; Paradies V; Vlachojannis G; Tellaroli P; Cortese B; di Palma G; Varricchio A; Ielasi A; Loi B; Steffenino G; Ueshima D; Mojoli M; Smits P
    Catheter Cardiovasc Interv; 2018 Aug; 92(2):E115-E124. PubMed ID: 29513403
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Procedural findings and early healing response after implantation of a self-apposing bioresorbable scaffold in coronary bifurcation lesions.
    Holck EN; Fox-Maule C; Barkholt TØ; Jakobsen L; Tu S; Maeng M; Dijkstra J; Christiansen EH; Holm NR
    Int J Cardiovasc Imaging; 2019 Jul; 35(7):1199-1210. PubMed ID: 31053981
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Two-year clinical, angiographic, and serial optical coherence tomographic follow-up after implantation of an everolimus-eluting bioresorbable scaffold and an everolimus-eluting metallic stent: insights from the randomised ABSORB Japan trial.
    Onuma Y; Sotomi Y; Shiomi H; Ozaki Y; Namiki A; Yasuda S; Ueno T; Ando K; Furuya J; Igarashi K; Kozuma K; Tanabe K; Kusano H; Rapoza R; Popma JJ; Stone GW; Simonton C; Serruys PW; Kimura T
    EuroIntervention; 2016 Oct; 12(9):1090-1101. PubMed ID: 27597270
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.