  • 1. Influence of multiple reuse and resterilization cycles on the performance of a bipolar vessel sealing device (LigaSure) intended for single use.
    Kuvaldina A; Hayes G; Sumner J; Behling-Kelly E
    Vet Surg; 2018 Oct; 47(7):951-957. PubMed ID: 30180278
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Performance and microbiological safety testing after multiple use cycles and hydrogen peroxide sterilization of a 5-mm vessel-sealing device.
    Valenzano D; Hayes G; Gludish D; Weese S
    Vet Surg; 2019 Jul; 48(5):885-889. PubMed ID: 30882923
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of the performance of an endoscopic 3-mm electrothermal bipolar vessel sealing device intended for single use after multiple use-and-resterilization cycles.
    Quitzan JG; Singh A; Beaufrere H; Valverde A; Lillie B; Salahshoor M; Bardelcik A; Saleh TM
    Vet Surg; 2020 Jun; 49 Suppl 1():O120-O130. PubMed ID: 32053219
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Efficacy and quality of vessel sealing: comparison of a reusable with a disposable device and effects of clamp surface geometry and structure.
    Richter S; Kollmar O; Schilling MK; Pistorius GA; Menger MD
    Surg Endosc; 2006 Jun; 20(6):890-4. PubMed ID: 16738977
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Differential response of arteries and veins to bipolar vessel sealing: evaluation of a novel reusable device.
    Richter S; Kollmar O; Neunhoeffer E; Schilling MK; Menger MD; Pistorius G
    J Laparoendosc Adv Surg Tech A; 2006 Apr; 16(2):149-55. PubMed ID: 16646707
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of multiple use and sterilization on sealing performance of bipolar vessel sealing devices.
    Gardeweg S; Bockstahler B; Duprè G
    PLoS One; 2019; 14(8):e0221488. PubMed ID: 31430327
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of vascular seal configuration using the LigaSure on arterial challenge pressure, time for seal creation, and histologic features.
    Matz BM; Tillson DM; Boothe HW; Dillon RA; Cattley RC
    Vet Surg; 2014 Aug; 43(6):761-4. PubMed ID: 24890308
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effectiveness of the ultrasonic coagulating shears, LigaSure vessel sealer, and surgical clip application in biliary surgery: a comparative analysis.
    Matthews BD; Pratt BL; Backus CL; Kercher KW; Mostafa G; Lentzner A; Lipford EH; Sing RF; Heniford BT
    Am Surg; 2001 Sep; 67(9):901-6. PubMed ID: 11565773
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Carotid artery bursting pressure and seal time after multiple uses of a vessel sealing device.
    Blake JS; Trumpatori BJ; Mathews KG; Griffith EH
    Vet Surg; 2017 May; 46(4):501-506. PubMed ID: 28334448
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of a Laparoscopic Ferromagnetic Technology-based Vessel Sealing Device and Comparative Study to Ultrasonic and Bipolar Laparoscopic Devices.
    Chen J; Jensen CR; Manwaring PK; Glasgow RE
    Surg Laparosc Endosc Percutan Tech; 2017 Apr; 27(2):e12-e17. PubMed ID: 28234706
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of surgical energy devices for vessel sealing and peripheral energy spread in a porcine model.
    Hruby GW; Marruffo FC; Durak E; Collins SM; Pierorazio P; Humphrey PA; Mansukhani MM; Landman J
    J Urol; 2007 Dec; 178(6):2689-93. PubMed ID: 17945280
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Bipolar vessel sealing: instrument contamination and wear have little effect on seal quality and success in a porcine in vitro model.
    Wallwiener CW; Junginger SH; Zubke W; Brucker SY; Enderle MD; Neugebauer A; Schönfisch B; Wallwiener M
    Langenbecks Arch Surg; 2014 Oct; 399(7):863-71. PubMed ID: 25064363
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of a reusable with a disposable vessel-sealing device in a sheep model: efficacy and costs.
    Klar M; Haberstroh J; Timme S; Fritzsch G; Gitsch G; Denschlag D
    Fertil Steril; 2011 Feb; 95(2):795-8. PubMed ID: 20951375
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Covidien LigaSure Maryland Jaw Device.
    Zaidi N; Glover AR; Sidhu SB
    Expert Rev Med Devices; 2015 Mar; 12(2):151-5. PubMed ID: 25431842
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of the efficacy of the electrosurgical bipolar vessel sealer (LigaSure) devices in sealing lymphatic vessels.
    Novitsky YW; Rosen MJ; Harrell AG; Sing RF; Kercher KW; Heniford BT
    Surg Innov; 2005 Jun; 12(2):155-60. PubMed ID: 16034506
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Can LigaSure seal and divide the small bowel?
    Salameh JR; Schwartz JH; Hildebrandt DA
    Am J Surg; 2006 Jun; 191(6):791-3. PubMed ID: 16720150
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of four energy-based vascular sealing and cutting instruments: A porcine model.
    Person B; Vivas DA; Ruiz D; Talcott M; Coad JE; Wexner SD
    Surg Endosc; 2008 Feb; 22(2):534-8. PubMed ID: 18097720
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparative study of in vivo lymphatic sealing capability of the porcine thoracic duct using laparoscopic dissection devices.
    Box GN; Lee HJ; Abraham JB; Deane LA; Elchico ER; Abdelshehid CA; Alipanah R; Taylor MB; Andrade L; Edwards RA; Borin JF; McDougall EM; Clayman RV
    J Urol; 2009 Jan; 181(1):387-91. PubMed ID: 19010491
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model.
    Landman J; Kerbl K; Rehman J; Andreoni C; Humphrey PA; Collyer W; Olweny E; Sundaram C; Clayman RV
    J Urol; 2003 Feb; 169(2):697-700. PubMed ID: 12544345
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Double Bipolar Sealing of the Pulmonary Artery Improves the Bursting Pressures.
    Kirschbaum A; Vom Hofe B; Pehl A; Bartsch DK
    Thorac Cardiovasc Surg; 2017 Aug; 65(5):351-355. PubMed ID: 26669770
    [No Abstract]   [Full Text] [Related]  