BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 30181966)

  • 1. Photoneutron Dose Estimation in GRID Therapy Using an Anthropomorphic Phantom: A Monte Carlo Study.
    Chegeni N; Karimi AH; Jabbari I; Arvandi S
    J Med Signals Sens; 2018; 8(3):175-183. PubMed ID: 30181966
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Feasibility of 18-MV grid therapy from radiation protection aspects: unwanted dose and fatal cancer risk caused by photoneutrons and scattered photons.
    Karimi AH; Mirian SF; Mahmoudi F; Geraily G; Vega-Carrillo HR; Mohiuddin M
    Comput Methods Programs Biomed; 2022 Jan; 213():106524. PubMed ID: 34818621
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of the linac neutron dose profile for various depths and field sizes: a Monte Carlo study.
    Prasada DNY; Ciamaudi N; Fadli M; Tursinah R; Pawiro SA
    Biomed Phys Eng Express; 2021 Oct; 7(6):. PubMed ID: 34619664
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A Monte Carlo Study for Photoneutron Dose Estimations around the High-Energy Linacs.
    Mohammadi N; Miri-Hakimabad SH; Rafat-Motavalli L
    J Biomed Phys Eng; 2014 Dec; 4(4):127-40. PubMed ID: 25599059
    [TBL] [Abstract][Full Text] [Related]  

  • 5. How much should you worry about contaminant neutrons in spatially fractionated grid radiation therapy?
    Mahmoudi F; Mohammadi N; Haghighi M; Alirezaei Z; Jabbari I; Chegeni N; Elmtalab S; Vega-Carrillo HR; Kazemian A; Geraily G; Karimi AH
    PLoS One; 2023; 18(1):e0280433. PubMed ID: 36638131
    [TBL] [Abstract][Full Text] [Related]  

  • 6. MCNPX Estimation of Photoneutron Dose to Eye Voxel Anthropomorphic Phantom From 18 MV Linear Accelerator.
    Alghamdi AA
    Dose Response; 2023; 21(2):15593258231169807. PubMed ID: 37077717
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Grid therapy vs. conventional radiotherapy - 18 MV treatments: Photoneutron contamination along the maze of a linac bunker.
    Karimi AH; Vega-Carrillo HR
    Appl Radiat Isot; 2020 Apr; 158():109064. PubMed ID: 32174378
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of the flattening filter on photoneutron production at 10 MV in the Varian TrueBeam linear accelerator.
    Montgomery L; Evans M; Liang L; Maglieri R; Kildea J
    Med Phys; 2018 Oct; 45(10):4711-4719. PubMed ID: 30141186
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Study of Photoneutron Production for the 18 MV Photon Beam of the Siemens Medical linac by Monte Carlo Simulation.
    H D; A A M; M G; S M; C K
    J Biomed Phys Eng; 2020 Dec; 10(6):679-690. PubMed ID: 33364205
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of wedge filter and field size on photoneutron dose equivalent for an 18MV photon beam of a medical linear accelerator.
    Mesbahi A; Keshtkar A; Mohammadi E; Mohammadzadeh M
    Appl Radiat Isot; 2010 Jan; 68(1):84-9. PubMed ID: 19748787
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Neutron dose measurements of Varian and Elekta linacs by TLD600 and TLD700 dosimeters and comparison with MCNP calculations.
    Nedaie HA; Darestani H; Banaee N; Shagholi N; Mohammadi K; Shahvar A; Bayat E
    J Med Phys; 2014 Jan; 39(1):10-7. PubMed ID: 24600167
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of the effectiveness of steel for shielding photoneutrons produced in medical linear accelerators: A Monte Carlo particle transport study.
    Moghaddasi L; Colyer C
    Phys Med; 2022 Jun; 98():53-62. PubMed ID: 35490530
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Monte Carlo study on the secondary cancer risk estimations for patients undergoing prostate radiotherapy: A humanoid phantom study.
    Ghasemi-Jangjoo A; Ghiasi H
    Rep Pract Oncol Radiother; 2020; 25(2):187-192. PubMed ID: 32021575
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Estimation of photoneutron dosimetric characteristics in tissues/organs using an improved simple model of linac head.
    Khabaz R; Boodaghi R; Benam MR; Zanganeh V
    Appl Radiat Isot; 2018 Mar; 133():88-94. PubMed ID: 29310104
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characterization of photoneutron fluxes emitted by electron accelerators in the 4-20 MeV range using Monte Carlo codes: A critical review.
    Sari A
    Appl Radiat Isot; 2023 Jan; 191():110506. PubMed ID: 36370471
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monte Carlo simulation of neutron dose equivalent by photoneutron production inside the primary barriers of a radiotherapy vault.
    Choi CH; Park SY; Park JM; Chun M; Kim JI
    Phys Med; 2018 Apr; 48():1-5. PubMed ID: 29728220
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Essential considerations for accurate evaluation of photoneutron contamination in Radiotherapy.
    Karimi AH; Brkić H; Shahbazi-Gahrouei D; Haghighi SB; Jabbari I
    Appl Radiat Isot; 2019 Mar; 145():24-31. PubMed ID: 30572262
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Bremsstrahlung and photoneutron production in a steel shield for 15-22-MeV clinical electron beams.
    Fujita Y; Myojoyama A; Saitoh H
    Radiat Prot Dosimetry; 2015 Feb; 163(2):148-59. PubMed ID: 24821930
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of Photoneutron Dose Measured by Bubble Detectors in Conventional Linacs and Cyberknife Unit: Effective Dose and Secondary Malignancy Risk Estimation.
    Biltekin F; Yeginer M; Ozyigit G
    Technol Cancer Res Treat; 2016 Aug; 15(4):560-5. PubMed ID: 26152750
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs.
    Chibani O; Ma CM
    Med Phys; 2003 Aug; 30(8):1990-2000. PubMed ID: 12945965
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.