BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 30183687)

  • 1. Relating ionization quenching in organic plastic scintillators to basic material properties by modelling excitation density transport and amorphous track structure during proton irradiation.
    Christensen JB; Andersen CE
    Phys Med Biol; 2018 Sep; 63(19):195010. PubMed ID: 30183687
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ionization quenching in scintillators used for dosimetry of mixed particle fields.
    Christensen JB; Almhagen E; Stolarczyk L; Vestergaard A; Bassler N; Andersen CE
    Phys Med Biol; 2019 Apr; 64(9):095018. PubMed ID: 30909170
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A real-time method to simultaneously measure linear energy transfer and dose for proton therapy using organic scintillators.
    Alsanea F; Therriault-Proulx F; Sawakuchi G; Beddar S
    Med Phys; 2018 Apr; 45(4):1782-1789. PubMed ID: 29446078
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A systematic characterization of the low-energy photon response of plastic scintillation detectors.
    Boivin J; Beddar S; Bonde C; Schmidt D; Culberson W; Guillemette M; Beaulieu L
    Phys Med Biol; 2016 Aug; 61(15):5569-86. PubMed ID: 27384872
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Novel Gd
    Hoehr C; Morana A; Duhamel O; Capoen B; Trinczek M; Paillet P; Duzenli C; Bouazaoui M; Bouwmans G; Cassez A; Ouerdane Y; Boukenter A; El Hamzaoui H; Girard S
    Sci Rep; 2019 Nov; 9(1):16376. PubMed ID: 31704964
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ionization quenching correction for a 3D scintillator detector exposed to scanning proton beams.
    Alsanea F; Darne C; Robertson D; Beddar S
    Phys Med Biol; 2020 Apr; 65(7):075005. PubMed ID: 32079001
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Using a small-core graphite calorimeter for dosimetry and scintillator quenching corrections in a therapeutic proton beam.
    Christensen JB; Vestergaard A; Andersen CE
    Phys Med Biol; 2020 Nov; 65(21):215023. PubMed ID: 32526719
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Energy dependent response of plastic scintillation detectors to photon radiation of low to medium energy.
    Ebenau M; Radeck D; Bambynek M; Sommer H; Flühs D; Spaan B; Eichmann M
    Med Phys; 2016 Aug; 43(8):4598. PubMed ID: 27487876
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quality assurance in proton beam therapy using a plastic scintillator and a commercially available digital camera.
    Almurayshid M; Helo Y; Kacperek A; Griffiths J; Hebden J; Gibson A
    J Appl Clin Med Phys; 2017 Sep; 18(5):210-219. PubMed ID: 28755419
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Proton beam dosimetry: a comparison between a plastic scintillator, ionization chamber and Faraday cup.
    Ghergherehchi M; Afarideh H; Ghannadi M; Mohammadzadeh A; Aslani GR; Boghrati B
    J Radiat Res; 2010; 51(4):423-30. PubMed ID: 20679742
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of the water-equivalence of plastic materials in low- and high-energy clinical proton beams.
    Lourenço A; Shipley D; Wellock N; Thomas R; Bouchard H; Kacperek A; Fracchiolla F; Lorentini S; Schwarz M; MacDougall N; Royle G; Palmans H
    Phys Med Biol; 2017 May; 62(10):3883-3901. PubMed ID: 28319031
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterizing the response of miniature scintillation detectors when irradiated with proton beams.
    Archambault L; Polf JC; Beaulieu L; Beddar S
    Phys Med Biol; 2008 Apr; 53(7):1865-76. PubMed ID: 18364543
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Quantifying the impact of lead doping on plastic scintillator response to radiation.
    Nusrat H; Pang G; Ahmad SB; Keller B; Sarfehnia A
    Med Phys; 2019 Sep; 46(9):4215-4223. PubMed ID: 31264229
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Characterization of a plastic scintillating detector for the Small Animal Radiation Research Platform (SARRP).
    Johnstone CD; Therriault-Proulx F; Beaulieu L; Bazalova-Carter M
    Med Phys; 2019 Jan; 46(1):394-404. PubMed ID: 30417377
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography.
    Hoerner MR; Stepusin EJ; Hyer DE; Hintenlang DE
    Med Phys; 2015 Mar; 42(3):1268-79. PubMed ID: 25735282
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Preliminary investigations on the determination of three-dimensional dose distributions using scintillator blocks and optical tomography.
    Kroll F; Pawelke J; Karsch L
    Med Phys; 2013 Aug; 40(8):082104. PubMed ID: 23927341
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy.
    Linares Rosales HM; Duguay-Drouin P; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2019 May; 46(5):2412-2421. PubMed ID: 30891803
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Correction of stopping power and LET quenching for radiophotoluminescent glass dosimetry in a therapeutic proton beam.
    Chang W; Koba Y; Katayose T; Yasui K; Omachi C; Hariu M; Saitoh H
    Phys Med Biol; 2017 Nov; 62(23):8869-8881. PubMed ID: 28980978
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quenching correction for volumetric scintillation dosimetry of proton beams.
    Robertson D; Mirkovic D; Sahoo N; Beddar S
    Phys Med Biol; 2013 Jan; 58(2):261-73. PubMed ID: 23257200
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fabrication and characterization of a stemless plastic scintillation detector.
    Hupman MA; Monajemi T; Valitova I; Hill IG; Syme A
    Med Phys; 2020 Nov; 47(11):5882-5889. PubMed ID: 32966652
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.