These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 30185017)

  • 21. [Primary clinical result of digital template as navigation to supper cervical pedicle instrumentation].
    Lu S; Xu YQ; Zhang YZ; Li YB; Shi JH; Chen GP; Li DP; Fan QS
    Zhonghua Wai Ke Za Zhi; 2009 Mar; 47(5):359-62. PubMed ID: 19595014
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A novel screw guiding method with a screw guide template system for posterior C-2 fixation: clinical article.
    Kaneyama S; Sugawara T; Sumi M; Higashiyama N; Takabatake M; Mizoi K
    J Neurosurg Spine; 2014 Aug; 21(2):231-8. PubMed ID: 24785974
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of the clinical accuracy of cervical (C2-C7) pedicle screw insertion assisted by fluoroscopy, computed tomography-based navigation, and intraoperative three-dimensional C-arm navigation.
    Liu YJ; Tian W; Liu B; Li Q; Hu L; Li ZY; Yuan Q; Lü YW; Sun YZ
    Chin Med J (Engl); 2010 Nov; 123(21):2995-8. PubMed ID: 21162944
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Error rate of multi-level rapid prototyping trajectories for pedicle screw placement in lumbar and sacral spine.
    Merc M; Drstvensek I; Vogrin M; Brajlih T; Friedrich T; Recnik G
    Chin J Traumatol; 2014; 17(5):261-6. PubMed ID: 25293895
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Cervical Spine Pedicle Screw Accuracy in Fluoroscopic, Navigated and Template Guided Systems-A Systematic Review.
    Mahmoud A; Shanmuganathan K; Rocos B; Sedra F; Montgomery A; Aftab S
    Tomography; 2021 Oct; 7(4):614-622. PubMed ID: 34698301
    [No Abstract]   [Full Text] [Related]  

  • 26. [Accuracy of CT-based navigation of pedicle screws implantation in the cervical spine compared with X-ray fluoroscopy technique].
    Liu YJ; Tian W; Liu B; Li Q; Hu L; Li ZY; Yuan Q; Xing YG; Wang YQ; Sun YZ
    Zhonghua Wai Ke Za Zhi; 2005 Oct; 43(20):1328-30. PubMed ID: 16271246
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Screw perforation rates in 359 consecutive patients receiving computer-guided pedicle screw insertion along the cervical to lumbar spine.
    Uehara M; Takahashi J; Ikegami S; Kuraishi S; Futatsugi T; Kato H
    Eur Spine J; 2017 Nov; 26(11):2858-2864. PubMed ID: 27807776
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Accuracy and postoperative assessment of pedicle screw placement during scoliosis surgery with computer-assisted navigation: a meta-analysis.
    Tian W; Zeng C; An Y; Wang C; Liu Y; Li J
    Int J Med Robot; 2017 Mar; 13(1):. PubMed ID: 26957362
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The accuracy of navigation and 3D image-guided placement for the placement of pedicle screws in congenital spine deformity.
    Larson AN; Polly DW; Guidera KJ; Mielke CH; Santos ER; Ledonio CG; Sembrano JN
    J Pediatr Orthop; 2012 Sep; 32(6):e23-9. PubMed ID: 22892631
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Safety and Efficacy of Reconstruction of Complex Cervical Spine Pathology Using Pedicle Screws Inserted with Stealth Navigation and 3D Image-Guided (O-Arm) Technology.
    Theologis AA; Burch S
    Spine (Phila Pa 1976); 2015 Sep; 40(18):1397-406. PubMed ID: 26426710
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Short-term effectiveness of spinal navigation with intra-operative three-dimensional-imaging modality in pedicle screw fixation for congenital scoliosis].
    Sun L; Song Y; Gong Q; Liu L; Zhou C; Zhou Z
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Feb; 27(2):129-34. PubMed ID: 23596675
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Learning curve of 3D fluoroscopy image-guided pedicle screw placement in the thoracolumbar spine.
    Ryang YM; Villard J; Obermüller T; Friedrich B; Wolf P; Gempt J; Ringel F; Meyer B
    Spine J; 2015 Mar; 15(3):467-76. PubMed ID: 25315133
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Rapid prototype patient-specific drill template for cervical pedicle screw placement.
    Owen BD; Christensen GE; Reinhardt JM; Ryken TC
    Comput Aided Surg; 2007 Sep; 12(5):303-8. PubMed ID: 17957538
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Deviation analysis of atlantoaxial pedicle screws assisted by a drill template.
    Hu Y; Yuan ZS; Kepler CK; Albert TJ; Xie H; Yuan JB; Dong WX; Wang CT
    Orthopedics; 2014 May; 37(5):e420-7. PubMed ID: 24810817
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Design and Application of a Novel Patient-Specific Three-Dimensional Printed Drill Navigational Guiding in Atlantoaxial Pedicle Screw Placement.
    Pu X; Yin M; Ma J; Liu Y; Chen G; Huang Q; Zhao G; Lu T; Yao S; Chen Q; Luo C
    World Neurosurg; 2018 Jun; 114():e1-e10. PubMed ID: 29241694
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Pediatric Lumbar Pedicle Screw Placement Using Navigation Templates: A Cadaveric Study.
    Wang X; Shi J; Zhang S; Zhang Z; Li X; Li Z
    Indian J Orthop; 2017; 51(4):468-473. PubMed ID: 28790477
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Does Navigation Improve Accuracy of Placement of Pedicle Screws in Single-level Lumbar Degenerative Spondylolisthesis?: A Comparison Between Free-hand and Three-dimensional O-Arm Navigation Techniques.
    Boon Tow BP; Yue WM; Srivastava A; Lai JM; Guo CM; Wearn Peng BC; Chen JL; Yew AK; Seng C; Tan SB
    J Spinal Disord Tech; 2015 Oct; 28(8):E472-7. PubMed ID: 23981926
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Intraoperative, full-rotation, three-dimensional image (O-arm)-based navigation system for cervical pedicle screw insertion.
    Ishikawa Y; Kanemura T; Yoshida G; Matsumoto A; Ito Z; Tauchi R; Muramoto A; Ohno S; Nishimura Y
    J Neurosurg Spine; 2011 Nov; 15(5):472-8. PubMed ID: 21761967
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Accuracy assessment of atlantoaxial pedicle screws assisted by a novel drill guide template.
    Jiang L; Dong L; Tan M; Yang F; Yi P; Tang X
    Arch Orthop Trauma Surg; 2016 Nov; 136(11):1483-1490. PubMed ID: 27531494
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [A novel computer-assisted drill template for atlantoaxial pedicle screw placement:a cadaveric experimental study].
    Hu Y; Yuan ZS; Xie H; Yuan JB; Dong WX; Wang CT
    Zhonghua Yi Xue Za Zhi; 2013 Sep; 93(33):2659-63. PubMed ID: 24360048
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.