291 related articles for article (PubMed ID: 30196768)
1. OneShot-M: A New Device for Close Laparoscopy Pneumoperitoneum.
Cassata G; Palumbo V; Cicero L; De Luca A; Damiano G; Fazzotta S; Buscemi S; Lo Monte AI
Surg Innov; 2018 Dec; 25(6):570-577. PubMed ID: 30196768
[TBL] [Abstract][Full Text] [Related]
2. Injuries caused by Veress needle insertion for creation of pneumoperitoneum: a systematic literature review.
Azevedo JL; Azevedo OC; Miyahira SA; Miguel GP; Becker OM; Hypólito OH; Machado AC; Cardia W; Yamaguchi GA; Godinho L; Freire D; Almeida CE; Moreira CH; Freire DF
Surg Endosc; 2009 Jul; 23(7):1428-32. PubMed ID: 19263124
[TBL] [Abstract][Full Text] [Related]
3. Laparoscopic entry: a review of techniques, technologies, and complications.
Vilos GA; Ternamian A; Dempster J; Laberge PY;
J Obstet Gynaecol Can; 2007 May; 29(5):433-447. PubMed ID: 17493376
[TBL] [Abstract][Full Text] [Related]
4. Safe Veress needle insertion.
Cakir T; Tuney D; Esmaeilzadem S; Aktan AO
J Hepatobiliary Pancreat Surg; 2006; 13(3):225-7. PubMed ID: 16708299
[TBL] [Abstract][Full Text] [Related]
5. Veress Needle Creation of a Pneumoperitoneum: Is It Risky? Results of the First Belgian Group for Endoscopic Surgery-Snapshot Study.
Wolthuis AM
J Laparoendosc Adv Surg Tech A; 2019 Aug; 29(8):1023-1026. PubMed ID: 31140894
[No Abstract] [Full Text] [Related]
6. The role of optical access trocars in laparoscopic surgery.
Schoonderwoerd L; Swank DJ
Surg Technol Int; 2005; 14():61-7. PubMed ID: 16525956
[TBL] [Abstract][Full Text] [Related]
7. A new technique in laparoscopic abdominal access (Evsen Method, Modified Veress Technique).
Evsen MS; Icen MS; Findik FM; Tunc SY; Ağaçayak E; Gul T
Ginekol Pol; 2018; 89(9):481-484. PubMed ID: 30318574
[TBL] [Abstract][Full Text] [Related]
8. Direct trocar insertion without previous pneumoperitoneum versus insertion after insufflation with Veress needle in laparoscopic gynecological surgery: a prospective cohort study.
Pantoja Garrido M; Frías Sánchez Z; Zapardiel Gutiérrez I; Torrejón R; Jiménez Sánchez C; Polo Velasco A; Márquez Maraver F; Rodríguez Jiménez I; Jiménez Gallardo J; Fernández Alba JJ
J Obstet Gynaecol; 2019 Oct; 39(7):1000-1005. PubMed ID: 31210067
[TBL] [Abstract][Full Text] [Related]
9. Access techniques: Veress needle--initial blind trocar insertion versus open laparoscopy with the Hasson trocar.
McKernan JB; Champion JK
Endosc Surg Allied Technol; 1995 Feb; 3(1):35-8. PubMed ID: 7757437
[TBL] [Abstract][Full Text] [Related]
10. Induction of pneumoperitoneum in morbidly obese patients.
Schwartz ML; Drew RL; Andersen JN
Obes Surg; 2003 Aug; 13(4):601-4; discussion 604. PubMed ID: 12935362
[TBL] [Abstract][Full Text] [Related]
11. Randomized control trial on effectiveness and safety of direct trocar versus Veress needle entry techniques in obese women during diagnostic laparoscopy.
Ikechebelu JI; Eleje GU; Joe-Ikechebelu NN; Okafor CD; Okpala BC; Ugwu EO; Nwachukwu CE; Okoro CC; Okam PC
Arch Gynecol Obstet; 2021 Sep; 304(3):815-822. PubMed ID: 33417065
[TBL] [Abstract][Full Text] [Related]
12. Latif's point: A new point for Veress needle insertion for pneumoperitoneum in difficult laparoscopy.
Abd Ellatif ME; Ghnnam WM; Abbas A; Basheer M; Dawoud I; Ellaithy R
Asian J Endosc Surg; 2018 May; 11(2):133-137. PubMed ID: 28856845
[TBL] [Abstract][Full Text] [Related]
13. The safety and efficacy of direct trocar insertion with elevation of the rectus sheath instead of the skin for pneumoperitoneum.
Günenç MZ; Yesildaglar N; Bingöl B; Onalan G; Tabak S; Gökmen B
Surg Laparosc Endosc Percutan Tech; 2005 Apr; 15(2):80-1. PubMed ID: 15821619
[TBL] [Abstract][Full Text] [Related]
14. The Veress needle causes most laparoscopic injuries and should be abandoned: FOR: the open technique is safer and saves time.
Vindal A; Lal P
BJOG; 2015 Jan; 122(1):141. PubMed ID: 25545904
[No Abstract] [Full Text] [Related]
15. Routine use of open technique in laparoscopic operations.
Nuzzo G; Giuliante F; Tebala GD; Vellone M; Cavicchioni C
J Am Coll Surg; 1997 Jan; 184(1):58-62. PubMed ID: 8989301
[TBL] [Abstract][Full Text] [Related]
16. Laparoscopic Entry Technique Using a Veress Needle Insertion with and without Concomitant CO
Mikhail E; Tamhane N; Sarkar P; Sappenfield E; Tanner JP; Imudia AN
J Minim Invasive Gynecol; 2019; 26(7):1383-1388. PubMed ID: 30802609
[TBL] [Abstract][Full Text] [Related]
17. The all-seeing needle instead of the Veress needle in pediatric urologic laparoscopy.
Silay MS; Tepeler A; Sancaktutar AA; Kilincaslan H; Altay B; Erdem MR; Hatipoglu NK; Akcay M; Akman T; Armagan A
J Endourol; 2013 Nov; 27(11):1376-80. PubMed ID: 23560687
[TBL] [Abstract][Full Text] [Related]
18. Intraperitoneal pressure and volume of gas injected as effective parameters of the correct position of the Veress needle during creation of pneumoperitoneum.
Azevedo JL; Azevedo OC; Sorbello AA; Becker OM; Hypolito O; Freire D; Miyahira S; Guedes A; Azevedo GC
J Laparoendosc Adv Surg Tech A; 2009 Dec; 19(6):731-4. PubMed ID: 19792865
[TBL] [Abstract][Full Text] [Related]
19. Direct trocar versus veress needle entry for laparoscopy: a randomized clinical trial.
Zakherah MS
Gynecol Obstet Invest; 2010; 69(4):260-263. PubMed ID: 20090356
[TBL] [Abstract][Full Text] [Related]
20. Laparoscopic needles and trocars: an overview of designs and complications.
Oshinsky GS; Smith AD
J Laparoendosc Surg; 1992 Apr; 2(2):117-25. PubMed ID: 1534491
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]