  • 1. Systematic quality assurance of the BSD2000-3D MR-compatible hyperthermia applicator performance using MR temperature imaging.
    Mulder HT; Curto S; Paulides MM; Franckena M; van Rhoon GC
    Int J Hyperthermia; 2018; 35(1):305-313. PubMed ID: 30204006
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A multi-institution study: comparison of the heating patterns of five different MR-guided deep hyperthermia systems using an anthropomorphic phantom.
    Curto S; Mulder HT; Aklan B; Mils O; Schmidt M; Lamprecht U; Peller M; Wessalowski R; Lindner LH; Fietkau R; Zips D; van Holthe N; Franckena M; Paulides MM; van Rhoon GC
    Int J Hyperthermia; 2020; 37(1):1103-1115. PubMed ID: 32981391
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A practical approach to thermography in a hyperthermia/magnetic resonance hybrid system: validation in a heterogeneous phantom.
    Gellermann J; Wlodarczyk W; Ganter H; Nadobny J; Fähling H; Seebass M; Felix R; Wust P
    Int J Radiat Oncol Biol Phys; 2005 Jan; 61(1):267-77. PubMed ID: 15629620
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High intensity focused ultrasound induced in vivo large volume hyperthermia under 3D MRI temperature control.
    Tillander M; Hokland S; Koskela J; Dam H; Andersen NP; Pedersen M; Tanderup K; Ylihautala M; Köhler M
    Med Phys; 2016 Mar; 43(3):1539-49. PubMed ID: 26936737
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Real-time MRI-guided hyperthermia treatment using a fast adaptive algorithm.
    Stakhursky VL; Arabe O; Cheng KS; Macfall J; Maccarini P; Craciunescu O; Dewhirst M; Stauffer P; Das SK
    Phys Med Biol; 2009 Apr; 54(7):2131-45. PubMed ID: 19287081
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reduction of peak acoustic pressure and shaping of heated region by use of multifoci sonications in MR-guided high-intensity focused ultrasound mediated mild hyperthermia.
    Partanen A; Tillander M; Yarmolenko PS; Wood BJ; Dreher MR; Kohler MO
    Med Phys; 2013 Jan; 40(1):013301. PubMed ID: 23298120
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Thermal magnetic resonance: physics considerations and electromagnetic field simulations up to 23.5 Tesla (1GHz).
    Winter L; Oezerdem C; Hoffmann W; van de Lindt T; Periquito J; Ji Y; Ghadjar P; Budach V; Wust P; Niendorf T
    Radiat Oncol; 2015 Sep; 10():201. PubMed ID: 26391138
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simulation-based design and characterization of a microwave applicator for MR-guided hyperthermia experimental studies in small animals.
    Faridi P; Bossmann SH; Prakash P
    Biomed Phys Eng Express; 2020 Jan; 6(1):. PubMed ID: 32999735
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Design and evaluation of a hybrid radiofrequency applicator for magnetic resonance imaging and RF induced hyperthermia: electromagnetic field simulations up to 14.0 Tesla and proof-of-concept at 7.0 Tesla.
    Winter L; Özerdem C; Hoffmann W; Santoro D; Müller A; Waiczies H; Seemann R; Graessl A; Wust P; Niendorf T
    PLoS One; 2013; 8(4):e61661. PubMed ID: 23613896
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Exploration of MR-guided head and neck hyperthermia by phantom testing of a modified prototype applicator for use with proton resonance frequency shift thermometry.
    Numan WC; Hofstetter LW; Kotek G; Bakker JF; Fiveland EW; Houston GC; Kudielka G; Yeo DT; Paulides MM
    Int J Hyperthermia; 2014 May; 30(3):184-91. PubMed ID: 24773040
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An MR-compatible antenna and application in a murine superficial hyperthermia applicator.
    Raaijmakers EAL; Mestrom RMC; Sumser K; Salim G; van Rhoon GC; Essers J; Paulides MM
    Int J Hyperthermia; 2018 Sep; 34(6):697-703. PubMed ID: 28828891
    [TBL] [Abstract][Full Text] [Related]  

  • 12. RHyThM, a tool for analysis of PDOS formatted hyperthermia treatment data generated by the BSD2000/3D system.
    Fatehi D; de Bruijne M; van der Zee J; van Rhoon GC
    Int J Hyperthermia; 2006 Mar; 22(2):173-84. PubMed ID: 16754600
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Interstitial ultrasound heating applicator for MR-guided thermal therapy.
    Chopra R; Luginbuhl C; Weymouth AJ; Foster FS; Bronskill MJ
    Phys Med Biol; 2001 Dec; 46(12):3133-45. PubMed ID: 11768496
    [TBL] [Abstract][Full Text] [Related]  

  • 14. POD-Kalman filtering for improving noninvasive 3D temperature monitoring in MR-guided hyperthermia.
    VilasBoas-Ribeiro I; Nouwens SAN; Curto S; Jager B; Franckena M; van Rhoon GC; Heemels WPMH; Paulides MM
    Med Phys; 2022 Aug; 49(8):4955-4970. PubMed ID: 35717578
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Online feedback focusing algorithm for hyperthermia cancer treatment.
    Cheng KS; Stakhursky V; Stauffer P; Dewhirst M; Das SK
    Int J Hyperthermia; 2007 Nov; 23(7):539-54. PubMed ID: 17943551
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Characterization of the SAR-distribution of the Sigma-60 applicator for regional hyperthermia using a Schottky diode sheet.
    Van Rhoon GC; Van Der Heuvel DJ; Ameziane A; Rietveld PJ; Volenec K; Van Der Zee J
    Int J Hyperthermia; 2003; 19(6):642-54. PubMed ID: 14756453
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging.
    Viallon M; Terraz S; Roland J; Dumont E; Becker CD; Salomir R
    Med Phys; 2010 Apr; 37(4):1491-506. PubMed ID: 20443470
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improved hyperthermia treatment control using SAR/temperature simulation and PRFS magnetic resonance thermal imaging.
    Li Z; Vogel M; Maccarini PF; Stakhursky V; Soher BJ; Craciunescu OI; Das S; Arabe OA; Joines WT; Stauffer PR
    Int J Hyperthermia; 2011; 27(1):86-99. PubMed ID: 21070140
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An easy-to-use microwave hyperthermia system combined with spatially resolved MR temperature maps: phantom and animal studies.
    Demura K; Morikawa S; Murakami K; Sato K; Shiomi H; Naka S; Kurumi Y; Inubushi T; Tani T
    J Surg Res; 2006 Sep; 135(1):179-86. PubMed ID: 16580694
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Interleaved Mapping of Temperature and Longitudinal Relaxation Rate to Monitor Drug Delivery During Magnetic Resonance-Guided High-Intensity Focused Ultrasound-Induced Hyperthermia.
    Kneepkens E; Heijman E; Keupp J; Weiss S; Nicolay K; Grüll H
    Invest Radiol; 2017 Oct; 52(10):620-630. PubMed ID: 28598900
    [TBL] [Abstract][Full Text] [Related]  