These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
164 related articles for article (PubMed ID: 30204125)
1. Shared-photodetector readout to improve the sensitivity of positron emission tomography. Du J; Peng P; Bai X; Cherry SR Phys Med Biol; 2018 Oct; 63(20):205002. PubMed ID: 30204125 [TBL] [Abstract][Full Text] [Related]
2. Development of depth encoding small animal PET detectors using dual-ended readout of pixelated scintillator arrays with SiPMs. Kuang Z; Sang Z; Wang X; Fu X; Ren N; Zhang X; Zheng Y; Yang Q; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y Med Phys; 2018 Feb; 45(2):613-621. PubMed ID: 29222959 [TBL] [Abstract][Full Text] [Related]
3. A depth-of-interaction encoding PET detector module with dual-ended readout using large-area silicon photomultiplier arrays. Du J; Bai X; Cherry SR Phys Med Biol; 2018 Dec; 63(24):245019. PubMed ID: 30523925 [TBL] [Abstract][Full Text] [Related]
4. Performance of long rectangular semi-monolithic scintillator PET detectors. Zhang X; Wang X; Ren N; Hu B; Ding B; Kuang Z; Wu S; Sang Z; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y Med Phys; 2019 Apr; 46(4):1608-1619. PubMed ID: 30723932 [TBL] [Abstract][Full Text] [Related]
5. Design and evaluation of gapless curved scintillator arrays for simultaneous high-resolution and high-sensitivity brain PET. Du J; Bai X; Liu CC; Qi J; Cherry SR Phys Med Biol; 2019 Nov; 64(23):235004. PubMed ID: 31618708 [TBL] [Abstract][Full Text] [Related]
6. Performance comparison of two signal multiplexing readouts for SiPM-based pet detector. Yang Q; Kuang Z; Sang Z; Yang Y; Du J Phys Med Biol; 2019 Dec; 64(23):23NT02. PubMed ID: 31722318 [TBL] [Abstract][Full Text] [Related]
7. Evaluation of Matrix9 silicon photomultiplier array for small-animal PET. Du J; Schmall JP; Yang Y; Di K; Roncali E; Mitchell GS; Buckley S; Jackson C; Cherry SR Med Phys; 2015 Feb; 42(2):585. PubMed ID: 25652479 [TBL] [Abstract][Full Text] [Related]
8. A novel depth-of-interaction block detector for positron emission tomography using a dichotomous orthogonal symmetry decoding concept. Zhang Y; Yan H; Baghaei H; Wong WH Phys Med Biol; 2016 Feb; 61(4):1608-33. PubMed ID: 26836144 [TBL] [Abstract][Full Text] [Related]
9. An edge-readout, multilayer detector for positron emission tomography. Li X; Ruiz-Gonzalez M; Furenlid LR Med Phys; 2018 Jun; 45(6):2425-2438. PubMed ID: 29635734 [TBL] [Abstract][Full Text] [Related]
11. Performance of a high-resolution depth encoding PET detector using barium sulfate reflector. Kuang Z; Wang X; Li C; Deng X; Feng K; Hu Z; Fu X; Ren N; Zhang X; Zheng Y; Liang D; Liu X; Zheng H; Yang Y Phys Med Biol; 2017 Jul; 62(15):5945-5958. PubMed ID: 28682792 [TBL] [Abstract][Full Text] [Related]
12. Simulation study of PET detector limitations using continuous crystals. Cabello J; Etxebeste A; Llosá G; Ziegler SI Phys Med Biol; 2015 May; 60(9):3673-94. PubMed ID: 25884464 [TBL] [Abstract][Full Text] [Related]
13. Performance of a depth encoding PET detector module using light sharing and single-ended readout with SiPMs. Kuang Z; Yang Q; Wang X; Fu X; Ren N; Wu S; Zhang C; Zhao B; Sang Z; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y Phys Med Biol; 2019 Apr; 64(8):085012. PubMed ID: 30893674 [TBL] [Abstract][Full Text] [Related]
14. Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography. Habte F; Foudray AM; Olcott PD; Levin CS Phys Med Biol; 2007 Jul; 52(13):3753-72. PubMed ID: 17664575 [TBL] [Abstract][Full Text] [Related]
15. Feasibility study of a point-of-care positron emission tomography system with interactive imaging capability. Jiang J; Li K; Komarov S; O'Sullivan JA; Tai YC Med Phys; 2019 Apr; 46(4):1798-1813. PubMed ID: 30667069 [TBL] [Abstract][Full Text] [Related]
16. Technical note: Comparison of arithmetic mean and energy-weighted mean flood histogram generation methods for dual-ended readout positron emission tomography detectors. Cong L; Kuang Z; Sang Z; Wang X; Niu M; Yang Y Med Phys; 2022 Jul; 49(7):4455-4465. PubMed ID: 35567406 [TBL] [Abstract][Full Text] [Related]
17. A depth-encoding PET detector for high resolution PET using 1 mm SiPMs. Du J; Bai X; Cherry SR Phys Med Biol; 2020 Aug; 65(16):165011. PubMed ID: 32580180 [TBL] [Abstract][Full Text] [Related]
18. Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readout. Ren S; Yang Y; Cherry SR Med Phys; 2014 Jul; 41(7):072503. PubMed ID: 24989406 [TBL] [Abstract][Full Text] [Related]
19. High resolution detectors for whole-body PET scanners by using dual-ended readout. Liu Z; Niu M; Kuang Z; Ren N; Wu S; Cong L; Wang X; Sang Z; Williams C; Yang Y EJNMMI Phys; 2022 Apr; 9(1):29. PubMed ID: 35445890 [TBL] [Abstract][Full Text] [Related]
20. A depth-of-interaction PET detector using a stair-shaped reflector arrangement and a single-ended scintillation light readout. Son JW; Lee MS; Lee JS Phys Med Biol; 2017 Jan; 62(2):465-483. PubMed ID: 28000613 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]