56 related articles for article (PubMed ID: 3020635)
1. MR imaging of 22 Charnley-Müller total hip prostheses.
Lemmens JA; van Horn JR; den Boer J; van der Riet W; Ruijs JH
Rofo; 1986 Sep; 145(3):311-5. PubMed ID: 3020635
[TBL] [Abstract][Full Text] [Related]
2. [10-year follow-up of a homogeneous series of 467 total hip prostheses of the Charnley-Müller type. Study of 167 cases].
Kempf JF; Henky P; Disteldorf M; Babin SR; Schvingt E
Rev Chir Orthop Reparatrice Appar Mot; 1986; 72(4):283-96. PubMed ID: 3809646
[TBL] [Abstract][Full Text] [Related]
3. Conus hip prosthesis.
Wagner H; Wagner M
Acta Chir Orthop Traumatol Cech; 2001; 68(4):213-21. PubMed ID: 11706545
[TBL] [Abstract][Full Text] [Related]
4. [Long-term review of homogeneous and consecutive series of 100 "Charnley"-type total hip prostheses].
Gardes P; Favard L; Gardes JC
Rev Chir Orthop Reparatrice Appar Mot; 1996; 82(4):306-12. PubMed ID: 8952910
[TBL] [Abstract][Full Text] [Related]
5. [Aseptic loosening of the Charnley prosthesis].
Stringa G; Aglietti P; Di Muria GV; Buzzi R; Marcucci M
Arch Putti Chir Organi Mov; 1989; 37(1):49-63. PubMed ID: 2619546
[TBL] [Abstract][Full Text] [Related]
6. Ten-year survivorship of rough-surfaced femoral stem with geometry similar to Charnley femoral stem.
Datir SP; Kurta IC; Wynn-Jones CH
J Arthroplasty; 2006 Apr; 21(3):392-7. PubMed ID: 16627148
[TBL] [Abstract][Full Text] [Related]
7. [Early aseptic loosening of the CF 30 femoral stem].
Kovanda M; Havlícek V; Hudec J
Acta Chir Orthop Traumatol Cech; 2007 Feb; 74(1):59-64. PubMed ID: 17331456
[TBL] [Abstract][Full Text] [Related]
8. Femoral component loosening after total hip arthroplasty.
McBeath AA; Foltz RN
Clin Orthop Relat Res; 1979 Jun; (141):66-70. PubMed ID: 477126
[TBL] [Abstract][Full Text] [Related]
9. [Femoral reconstruction with endosteal bone allografts protected by a metallic mesh in reoperation of total hip prosthesis. 19 cases with an average follow-up of 83 months].
Migaud H; Jardin C; Fontaine C; Pierchon F; d'Herbomez O; Duquennoy A
Rev Chir Orthop Reparatrice Appar Mot; 1997; 83(4):360-7. PubMed ID: 9452810
[TBL] [Abstract][Full Text] [Related]
10. Long-term survival of the T-28 versus the TR-28 cemented total hip arthroplasties.
Meding JB; Nassif JM; Ritter MA
J Arthroplasty; 2000 Oct; 15(7):928-33. PubMed ID: 11061455
[TBL] [Abstract][Full Text] [Related]
11. [Total hip prosthesis according to Charnley. Review of our cases].
Stringa G; Aglietti P; Di Muria GV; Marcucci M; Buzzi R; Lucattelli G
Arch Putti Chir Organi Mov; 1989; 37(1):9-35. PubMed ID: 2619549
[TBL] [Abstract][Full Text] [Related]
12. Is "aseptic" loosening of the prosthetic cup after total hip replacement due to nonculturable bacterial pathogens in patients with low-grade infection?
Ince A; Rupp J; Frommelt L; Katzer A; Gille J; Löhr JF
Clin Infect Dis; 2004 Dec; 39(11):1599-603. PubMed ID: 15578358
[TBL] [Abstract][Full Text] [Related]
13. Revision total hip arthroplasty with titanium ingrowth prosthesis and bone grafting for failed cemented femoral component loosening.
Gustilo RB; Pasternak HS
Clin Orthop Relat Res; 1988 Oct; (235):111-9. PubMed ID: 3416518
[TBL] [Abstract][Full Text] [Related]
14. The European school of total hip arthroplasty and 35 years of total hip arthroplasty in the Czech Republic.
Cech O; Dzupa V
Acta Chir Orthop Traumatol Cech; 2005; 72(1):57-76. PubMed ID: 15860155
[TBL] [Abstract][Full Text] [Related]
15. [Erosion of polyethylene cupulae. Radiological study of 123 Charnley total prostheses].
Clarac JP; Pries P; Launay L; Martin P; Freychet H; Nonet P
Rev Chir Orthop Reparatrice Appar Mot; 1986; 72(2):97-100. PubMed ID: 3715101
[TBL] [Abstract][Full Text] [Related]
16. [Failure of acetabular cups fixed with cement and thick embedded wire mesh].
Bonnomet F; Vanhille W; Lefebvre Y; Clavert P; Gicquel P; Kempf JF
Rev Chir Orthop Reparatrice Appar Mot; 2001 Oct; 87(6):544-55. PubMed ID: 11685145
[TBL] [Abstract][Full Text] [Related]
17. Cobalt and chromium concentrations in patients with metal-on-metal and other cementless total hip arthroplasty.
Maezawa K; Nozawa M; Hirose T; Matsuda K; Yasuma M; Shitoto K; Kurosawa H
Arch Orthop Trauma Surg; 2002 Jun; 122(5):283-7. PubMed ID: 12070648
[TBL] [Abstract][Full Text] [Related]
18. [The use of Müller hip prostheses for post-traumatic injuries].
Broos PL; Stappaerts KH; Gruwez JA
Acta Chir Belg; 1987; 87(6):343-9. PubMed ID: 3451634
[TBL] [Abstract][Full Text] [Related]
19. Long-term survival of the Charnley low-friction total hip arthroplasty.
Hozack WJ; Rothman RH
Semin Arthroplasty; 1990 Jul; 1(1):3-6. PubMed ID: 10149550
[TBL] [Abstract][Full Text] [Related]
20. Ceramic endoprosthesis in total hip arthroplasty.
Riska EB
Clin Orthop Relat Res; 1993 Dec; (297):87-94. PubMed ID: 8242957
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]