These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

261 related articles for article (PubMed ID: 30209636)

  • 41. A comparative evaluation of EPR and OxyLite oximetry using a random sampling of pO(2) in a murine tumor.
    Vikram DS; Bratasz A; Ahmad R; Kuppusamy P
    Radiat Res; 2007 Sep; 168(3):308-15. PubMed ID: 17705635
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Functional electron paramagnetic resonance imaging of ischemic rat heart: Monitoring of tissue oxygenation and pH.
    Gorodetsky AA; Kirilyuk IA; Khramtsov VV; Komarov DA
    Magn Reson Med; 2016 Jul; 76(1):350-8. PubMed ID: 26301868
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Comparisons of measurements of pO2 in tissue in vivo by EPR oximetry and microelectrodes.
    Goda F; O'Hara JA; Liu KJ; Rhodes ES; Dunn JF; Swartz HM
    Adv Exp Med Biol; 1997; 411():543-9. PubMed ID: 9269471
    [No Abstract]   [Full Text] [Related]  

  • 44. High spatial resolution multisite EPR oximetry of transient focal cerebral ischemia in the rat.
    Williams BB; Hou H; Grinberg OY; Demidenko E; Swartz HM
    Antioxid Redox Signal; 2007 Oct; 9(10):1691-8. PubMed ID: 17678442
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Carbon blacks as EPR sensors for localized measurements of tissue oxygenation.
    Lan M; Beghein N; Charlier N; Gallez B
    Magn Reson Med; 2004 Jun; 51(6):1272-8. PubMed ID: 15170849
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Pre-clinical evaluation of OxyChip for long-term EPR oximetry.
    Hou H; Khan N; Gohain S; Kuppusamy ML; Kuppusamy P
    Biomed Microdevices; 2018 Mar; 20(2):29. PubMed ID: 29549438
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Injectable LiNc-BuO loaded microspheres as in vivo EPR oxygen sensors after co-implantation with tumor cells.
    Frank J; Gündel D; Drescher S; Thews O; Mäder K
    Free Radic Biol Med; 2015 Dec; 89():741-9. PubMed ID: 26459034
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Feasibility of in vivo three-dimensional T
    Kubota H; Komarov DA; Yasui H; Matsumoto S; Inanami O; Kirilyuk IA; Khramtsov VV; Hirata H
    MAGMA; 2017 Jun; 30(3):291-298. PubMed ID: 28063096
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Development and evaluation of biocompatible inks for the local measurement of oxygen using in vivo EPR.
    Charlier N; Beghein N; Gallez B
    NMR Biomed; 2004 Aug; 17(5):303-10. PubMed ID: 15366029
    [TBL] [Abstract][Full Text] [Related]  

  • 50. EPR spectroscopy and imaging of oxygen: applications to the gastrointestinal tract.
    Zweier JL; He G; Samouilov A; Kuppusamy P
    Adv Exp Med Biol; 2003; 530():123-31. PubMed ID: 14562710
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Developing in vivo EPR oximetry for clinical use.
    Swartz HM; Walczak T
    Adv Exp Med Biol; 1998; 454():243-52. PubMed ID: 9889898
    [TBL] [Abstract][Full Text] [Related]  

  • 52. A New EPR oximetry protocol to estimate the tissue oxygen consumption in vivo.
    Diepart C; Jordan BF; Gallez B
    Radiat Res; 2009 Aug; 172(2):220-5. PubMed ID: 19630526
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Synergistic combination of hyperoxygenation and radiotherapy by repeated assessments of tumor pO2 with EPR oximetry.
    Hou H; Dong R; Lariviere JP; Mupparaju SP; Swartz HM; Khan N
    J Radiat Res; 2011; 52(5):568-74. PubMed ID: 21799293
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Measuring Flap Oxygen Using Electron Paramagnetic Resonance Oximetry.
    Polacco MA; Hou H; Kuppusamy P; Chen EY
    Laryngoscope; 2019 Dec; 129(12):E415-E419. PubMed ID: 31034638
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Tumor pO2 assessments in human xenograft tumors measured by EPR oximetry: location of paramagnetic materials.
    O'Hara JA; Blumenthal RD; Grinberg OY; Grinberg S; Wilmot C; Goldenberg DM; Swartz HM
    Adv Exp Med Biol; 2003; 530():205-14. PubMed ID: 14562718
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Implantable microchip containing oxygen-sensing paramagnetic crystals for long-term, repeated, and multisite in vivo oximetry.
    Kmiec MM; Tse D; Mast JM; Ahmad R; Kuppusamy P
    Biomed Microdevices; 2019 Jul; 21(3):71. PubMed ID: 31286244
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Development and evaluation of biocompatible films of polytetrafluoroethylene polymers holding lithium phthalocyanine crystals for their use in EPR oximetry.
    Dinguizli M; Jeumont S; Beghein N; He J; Walczak T; Lesniewski PN; Hou H; Grinberg OY; Sucheta A; Swartz HM; Gallez B
    Biosens Bioelectron; 2006 Jan; 21(7):1015-22. PubMed ID: 16368480
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Application of magnetic field over-modulation for improved EPR linewidth measurements using probes with Lorentzian lineshape.
    Deng Y; Pandian RP; Ahmad R; Kuppusamy P; Zweier JL
    J Magn Reson; 2006 Aug; 181(2):254-61. PubMed ID: 16759891
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Impact of myo-inositol trispyrophosphate (ITPP) on tumour oxygenation and response to irradiation in rodent tumour models.
    Tran LB; Cao-Pham TT; Jordan BF; Deschoemaeker S; Heyerick A; Gallez B
    J Cell Mol Med; 2019 Mar; 23(3):1908-1916. PubMed ID: 30575283
    [TBL] [Abstract][Full Text] [Related]  

  • 60. EPR-based oximetric imaging: a combination of single point-based spatial encoding and T
    Matsumoto KI; Kishimoto S; Devasahayam N; Chandramouli GVR; Ogawa Y; Matsumoto S; Krishna MC; Subramanian S
    Magn Reson Med; 2018 Nov; 80(5):2275-2287. PubMed ID: 29582458
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.