These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

352 related articles for article (PubMed ID: 30212545)

  • 1. Effect of pupil dilation on biometric measurements and intraocular lens power calculations in schoolchildren.
    Wang X; Dong J; Tang M; Wang X; Wang H; Zhang S
    PLoS One; 2018; 13(9):e0203677. PubMed ID: 30212545
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of pupil dilation on the Barrett universal II (new generation), Haigis (4th generation), and SRK/T (3rd generation) intraocular lens calculation formulas: a retrospective study.
    Teshigawara T; Meguro A; Mizuki N
    BMC Ophthalmol; 2020 Jul; 20(1):299. PubMed ID: 32689973
    [TBL] [Abstract][Full Text] [Related]  

  • 3. EFFECT OF PHARMACOLOGICAL PUPIL DILATION ON INTRAOCULAR LENS POWER CALCULATION IN PATIENTS INDICATED FOR CATARACT SURGERY.
    Autrata D; Chrapek O; Drahorád S
    Cesk Slov Oftalmol; 2021; 77(4):192-200. PubMed ID: 34507495
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of pharmacological pupil dilation on measurements and iol power calculation made using the new swept-source optical coherence tomography-based optical biometer.
    Arriola-Villalobos P; Almendral-Gómez J; Garzón N; Ruiz-Medrano J; Fernández-Pérez C; Martínez-de-la-Casa JM; Díaz-Valle D
    J Fr Ophtalmol; 2016 Dec; 39(10):859-865. PubMed ID: 27793471
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of pupil dilation on biometry measurements with partial coherence interferometry and its effect on IOL power formula calculation.
    Rodriguez-Raton A; Jimenez-Alvarez M; Arteche-Limousin L; Mediavilla-Peña E; Larrucea-Martinez I
    Eur J Ophthalmol; 2015; 25(4):309-14. PubMed ID: 25655597
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The Effect of Pharmacological Dilation on Calculation of Targeted and Ideal IOL Power Using Multivariable Formulas.
    Simon NC; Farooq AV; Zhang MH; Riaz KM
    Ophthalmol Ther; 2020 Sep; 9(3):1-11. PubMed ID: 32462340
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of ocular biometric factors on the accuracy of various IOL power calculation formulas.
    Jeong J; Song H; Lee JK; Chuck RS; Kwon JW
    BMC Ophthalmol; 2017 May; 17(1):62. PubMed ID: 28464806
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of anterior chamber depth on the choice of intraocular lens calculation formula in patients with normal axial length.
    Miraftab M; Hashemi H; Fotouhi A; Khabazkhoob M; Rezvan F; Asgari S
    Middle East Afr J Ophthalmol; 2014; 21(4):307-11. PubMed ID: 25371635
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Changes in Ocular Parameters and Intraocular Lens Powers in Aging Cycloplegic Eyes.
    Özyol P; Özyol E; Baldemir E
    Am J Ophthalmol; 2017 Jan; 173():76-83. PubMed ID: 27702623
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Agreement of ocular biometric measurements in young healthy eyes between IOLMaster 700 and OA-2000.
    Liao X; Peng Y; Liu B; Tan QQ; Lan CJ
    Sci Rep; 2020 Feb; 10(1):3134. PubMed ID: 32081868
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of Two Optical Biometers.
    Shin MC; Chung SY; Hwang HS; Han KE
    Optom Vis Sci; 2016 Mar; 93(3):259-65. PubMed ID: 26760579
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of pupil dilation on biometric parameters of the Lenstar 900.
    Bakbak B; Koktekir BE; Gedik S; Guzel H
    Cornea; 2013 Apr; 32(4):e21-4. PubMed ID: 23023403
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of pupillary dilatation on IOL power measurement by using the IOLMaster.
    Khambhiphant B; Chatbunchachai N; Pongpirul K
    Int Ophthalmol; 2015 Dec; 35(6):853-9. PubMed ID: 25807912
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of pupillary dilation on ocular optical biometry outcomes in pediatric patients.
    Balsak S
    Arq Bras Oftalmol; 2020 Aug; 83(4):289-293. PubMed ID: 32756786
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of Holladay 2 formula using IOLMaster parameters in the absence of lens thickness value.
    Srivannaboon S; Chirapapaisan C; Chirapapaisan N; Lertsuwanroj B; Chongchareon M
    Graefes Arch Clin Exp Ophthalmol; 2013 Nov; 251(11):2563-7. PubMed ID: 23949638
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of intraocular lens power calculation formulas using a swept-source optical biometer.
    Kim SY; Lee SH; Kim NR; Chin HS; Jung JW
    PLoS One; 2020; 15(1):e0227638. PubMed ID: 31935241
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of pupil dilation on AL-Scan biometric parameters.
    Can E; Duran M; Çetinkaya T; Arıtürk N
    Int Ophthalmol; 2016 Apr; 36(2):179-83. PubMed ID: 26115695
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of pharmacologic pupil dilation on OLCR optical biometry measurements for IOL predictions.
    Arriola-Villalobos P; Díaz-Valle D; Garzòn N; Ruiz-Medrano J; Fernández-Perez C; Alejandre-Alba N; García-Feijoò J
    Eur J Ophthalmol; 2014; 24(1):53-7. PubMed ID: 23787456
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of the biometric measurements obtained using noncontact optical biometers LenStar LS 900 and IOL Master V.5.
    Kołodziejczyk W; Gałecki T; Łazicka-Gałecka M; Szaflik J
    Klin Oczna; 2011; 113(1-3):47-51. PubMed ID: 21853951
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The effect of cycloplegia on the ocular biometry and intraocular lens power based on age.
    Tuncer I; Zengin MÖ; Yıldız S
    Eye (Lond); 2021 Feb; 35(2):676-681. PubMed ID: 32796931
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.