BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

350 related articles for article (PubMed ID: 30216377)

  • 21. The Performance of a 2-Dimensional Shear-Wave Elastography Technique for Predicting Different Stages of Liver Fibrosis Using Transient Elastography as the Control Method.
    Bende F; Sporea I; Şirli R; Nistorescu S; Fofiu R; Bâldea V; Popescu A
    Ultrasound Q; 2020 Nov; 37(2):97-104. PubMed ID: 33136935
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Agreement and accuracy of shear-wave techniques (point shear-wave elastography and 2D-shear-wave elastography) using transient elastography as reference.
    Fernandes F; Piedade J; Freitas G; Area P; Santos R; Grinsztejn B; Veloso V; Pereira G; Perazzo H
    Eur J Gastroenterol Hepatol; 2022 Aug; 34(8):873-881. PubMed ID: 35802529
    [TBL] [Abstract][Full Text] [Related]  

  • 23. 2-dimensional shear wave elastography: Interobserver agreement and factors related to interobserver discrepancy.
    Yoon K; Jeong WK; Kim Y; Kim MY; Kim TY; Sohn JH
    PLoS One; 2017; 12(4):e0175747. PubMed ID: 28414822
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparative Utility of Transient and 2D Shear Wave Elastography for the Assessment of Liver Fibrosis in Clinical Practice.
    Karagiannakis DS; Voulgaris T; Angelopoulos T; Ioannidou P; Cholongitas E; Vlachogiannakos J; Papatheodoridis GV
    J Digit Imaging; 2021 Dec; 34(6):1342-1348. PubMed ID: 34622378
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Inflammatory activity affects the accuracy of liver stiffness measurement by transient elastography but not by two-dimensional shear wave elastography in non-alcoholic fatty liver disease.
    Mendoza YP; Rodrigues SG; Delgado MG; Murgia G; Lange NF; Schropp J; Montani M; Dufour JF; Berzigotti A
    Liver Int; 2022 Jan; 42(1):102-111. PubMed ID: 34821035
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Interconversion of elasticity measurements between two-dimensional shear wave elastography and transient elastography.
    Kim YY; Kim MJ; Shin HJ; Yoon H; Kim HY; Lee MJ
    Med Ultrason; 2018 May; 20(2):127-133. PubMed ID: 29730676
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Intra- and Inter-Observer Reproducibility of a 2-D Shear Wave Elastography Technique and the Impact of Ultrasound Experience in Achieving Reliable Data.
    Moga TV; Stepan AM; Pienar C; Bende F; Popescu A; Șirli R; Dănilă M; Sporea I
    Ultrasound Med Biol; 2018 Aug; 44(8):1627-1637. PubMed ID: 29801976
    [TBL] [Abstract][Full Text] [Related]  

  • 28. 2D-shear wave elastography: number of acquisitions can be reduced according to clinical setting.
    Dioguardi Burgio M; Grégory J; Ronot M; Sartoris R; Chatellier G; Vilgrain V;
    Insights Imaging; 2021 Oct; 12(1):145. PubMed ID: 34674032
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Liver Stiffness Assessed by Ultrasound Shear Wave Elastography from General Electric Accurately Predicts Clinically Significant Portal Hypertension in Patients with Advanced Chronic Liver Disease.
    Stefanescu H; Rusu C; Lupsor-Platon M; Nicoara Farcau O; Fischer P; Grigoras C; Horhat A; Stancu O; Ardelean A; Tantau M; Badea R; Procopet B
    Ultraschall Med; 2020 Oct; 41(5):526-533. PubMed ID: 31476787
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Prospective comparison of spleen and liver stiffness by using shear-wave and transient elastography for detection of portal hypertension in cirrhosis.
    Elkrief L; Rautou PE; Ronot M; Lambert S; Dioguardi Burgio M; Francoz C; Plessier A; Durand F; Valla D; Lebrec D; Vilgrain V; Castéra L
    Radiology; 2015 May; 275(2):589-98. PubMed ID: 25469784
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Staging of hepatic fibrosis: comparison of magnetic resonance elastography and shear wave elastography in the same individuals.
    Yoon JH; Lee JM; Woo HS; Yu MH; Joo I; Lee ES; Sohn JY; Lee KB; Han JK; Choi BI
    Korean J Radiol; 2013; 14(2):202-12. PubMed ID: 23483022
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Hepatic fibrosis: prospective comparison of MR elastography and US shear-wave elastography for evaluation.
    Yoon JH; Lee JM; Joo I; Lee ES; Sohn JY; Jang SK; Lee KB; Han JK; Choi BI
    Radiology; 2014 Dec; 273(3):772-82. PubMed ID: 25007047
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Technical performance of shear wave elastography for measuring liver stiffness in pediatric and adolescent patients: a systematic review and meta-analysis.
    Kim DW; Park C; Yoon HM; Jung AY; Lee JS; Jung SC; Cho YA
    Eur Radiol; 2019 May; 29(5):2560-2572. PubMed ID: 30617493
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Poor correlation of 2D shear wave elastography and transient elastography in Fontan-associated liver disease: A head-to-head comparison.
    Gill M; Mudaliar S; Prince D; Than NN; Cordina R; Majumdar A
    JGH Open; 2023 Oct; 7(10):690-697. PubMed ID: 37908293
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison between the M and XL probes for liver fibrosis assessment by transient elastography.
    Şirli R; Sporea I; Deleanu A; Culcea L; Szilaski M; Popescu A; Dănilă M
    Med Ultrason; 2014 Jun; 16(2):119-22. PubMed ID: 24791843
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of Two-Dimensional Shear Wave Elastography and Real-Time Tissue Elastography for Assessing Liver Fibrosis in Chronic Hepatitis B.
    Wu T; Wang P; Zhang T; Zheng J; Li S; Zeng J; Kudo M; Zheng R
    Dig Dis; 2016; 34(6):640-649. PubMed ID: 27750231
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Utility of Hepatic 2D Shear-Wave Elastography in Monitoring Response to Image-Guided Intervention in Children With Chronic Budd-Chiari Syndrome: A Prospective Study.
    Dohare N; Madhusudhan KS; Malik R; Das P; Sharma S
    AJR Am J Roentgenol; 2022 Mar; 218(3):534-543. PubMed ID: 34585610
    [No Abstract]   [Full Text] [Related]  

  • 38. Transcranial Shear Wave Elastography of Neonatal and Infant Brains for Quantitative Evaluation of Increased Intracranial Pressure.
    Dirrichs T; Meiser N; Panek A; Trepels-Kottek S; Orlikowsky T; Kuhl CK; Schrading S
    Invest Radiol; 2019 Nov; 54(11):719-727. PubMed ID: 31464808
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of three ultrasound based elastographic techniques in children and adolescents with chronic diffuse liver diseases.
    Belei O; Sporea I; Gradinaru-Tascau O; Olariu L; Popescu A; Simedrea I; Marginean O
    Med Ultrason; 2016 Jun; 18(2):145-50. PubMed ID: 27239646
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Real-time two-dimensional Shear-wave elastography for liver stiffness in children: Interobserver variation and effect of breathing technique.
    Yoon HM; Cho YA; Kim JR; Lee SS; Jung AY; Lee JS; Oh SH; Kim KM
    Eur J Radiol; 2017 Dec; 97():53-58. PubMed ID: 29153367
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 18.