134 related articles for article (PubMed ID: 30217160)
1. Development of a PMMA phantom as a practical alternative for quality control of gamma knife® dosimetry.
Chung JP; Seong YM; Kim TY; Choi Y; Kim TH; Choi HJ; Min CH; Benmakhlouf H; Chun KJ; Chung HT
Radiat Oncol; 2018 Sep; 13(1):176. PubMed ID: 30217160
[TBL] [Abstract][Full Text] [Related]
2. Verification of dose profiles generated by the convolution algorithm of the gamma knife
Chung HT; Park JH; Chun KJ
Med Phys; 2017 Sep; 44(9):4880-4889. PubMed ID: 28513854
[TBL] [Abstract][Full Text] [Related]
3. Calibration of the Gamma Knife Perfexion using TG-21 and the solid water Leksell dosimetry phantom.
McDonald D; Yount C; Koch N; Ashenafi M; Peng J; Vanek K
Med Phys; 2011 Mar; 38(3):1685-93. PubMed ID: 21520881
[TBL] [Abstract][Full Text] [Related]
4. Determination of kQmsr,Q0fmsr,fref factors for ion chambers used in the calibration of Leksell Gamma Knife Perfexion model using EGSnrc and PENELOPE Monte Carlo codes.
Mirzakhanian L; Benmakhlouf H; Tessier F; Seuntjens J
Med Phys; 2018 Apr; 45(4):1748-1757. PubMed ID: 29468677
[TBL] [Abstract][Full Text] [Related]
5. Verification of source and collimator configuration for Gamma Knife Perfexion using panoramic imaging.
Cho YB; van Prooijen M; Jaffray DA; Islam MK
Med Phys; 2010 Mar; 37(3):1325-31. PubMed ID: 20384269
[TBL] [Abstract][Full Text] [Related]
6. Air kerma based dosimetry calibration for the Leksell Gamma Knife.
Meltsner SG; DeWerd LA
Med Phys; 2009 Feb; 36(2):339-50. PubMed ID: 19291973
[TBL] [Abstract][Full Text] [Related]
7. Application of the gamma evaluation method in Gamma Knife film dosimetry.
Park JH; Han JH; Kim CY; Oh CW; Lee DH; Suh TS; Gyu Kim D; Chung HT
Med Phys; 2011 Oct; 38(10):5778-87. PubMed ID: 21992392
[TBL] [Abstract][Full Text] [Related]
8. A round-robin gamma stereotactic radiosurgery dosimetry interinstitution comparison of calibration protocols.
Drzymala RE; Alvarez PE; Bednarz G; Bourland JD; DeWerd LA; Ma L; Meltsner SG; Neyman G; Novotny J; Petti PL; Rivard MJ; Shiu AS; Goetsch SJ
Med Phys; 2015 Nov; 42(11):6745-56. PubMed ID: 26520764
[TBL] [Abstract][Full Text] [Related]
9. Consistency of dose rates after applying machine-specific reference correction factors for the gamma knife 16 mm collimator field.
Choi Y; Chun KJ; Kim ES; Bahng J; Yang HJ; Kim TH; Cho GS; Choi SH; Seo YC; Chung HT
Med Phys; 2023 Jun; 50(6):3816-3824. PubMed ID: 36700450
[TBL] [Abstract][Full Text] [Related]
10. Dosimetry of Gamma Knife and linac-based radiosurgery using radiochromic and diode detectors.
Somigliana A; Cattaneo GM; Fiorino C; Borelli S; del Vecchio A; Zonca G; Pignoli E; Loi G; Calandrino R; Marchesini R
Phys Med Biol; 1999 Apr; 44(4):887-97. PubMed ID: 10232803
[TBL] [Abstract][Full Text] [Related]
11. Ion chamber and film-based quality assurance of mixed electron-photon radiation therapy.
Heng VJ; Serban M; Seuntjens J; Renaud MA
Med Phys; 2021 Sep; 48(9):5382-5395. PubMed ID: 34224144
[TBL] [Abstract][Full Text] [Related]
12. Dosimetric comparison of the Leksell Gamma Knife Perfexion and 4C.
Novotny J; Bhatnagar JP; Niranjan A; Quader MA; Huq MS; Bednarz G; Flickinger JC; Kondziolka D; Lunsford LD
J Neurosurg; 2008 Dec; 109 Suppl():8-14. PubMed ID: 19123882
[TBL] [Abstract][Full Text] [Related]
13. Feasibility of isodose-shaped scintillation detectors for the measurement of gamma knife output factors.
Kim TH; Yang HJ; Jeong JY; Schaarschmidt T; Kim YK; Chung HT
Med Phys; 2022 Mar; 49(3):1944-1954. PubMed ID: 35050516
[TBL] [Abstract][Full Text] [Related]
14. Assessment and characterization of the total geometric uncertainty in Gamma Knife radiosurgery using polymer gels.
Moutsatsos A; Karaiskos P; Petrokokkinos L; Sakelliou L; Pantelis E; Georgiou E; Torrens M; Seimenis I
Med Phys; 2013 Mar; 40(3):031704. PubMed ID: 23464299
[TBL] [Abstract][Full Text] [Related]
15. Technical note: Influence of the phantom material on the absorbed-dose energy dependence of the EBT3 radiochromic film for photons in the energy range 3 keV-18 MeV.
Hermida-López M; Lüdemann L; Flühs A; Brualla L
Med Phys; 2014 Nov; 41(11):112103. PubMed ID: 25370654
[TBL] [Abstract][Full Text] [Related]
16. Calibration of the Gamma Knife using a new phantom following the AAPM TG51 and TG21 protocols.
Drzymala RE; Wood RC; Levy J
Med Phys; 2008 Feb; 35(2):514-21. PubMed ID: 18383672
[TBL] [Abstract][Full Text] [Related]
17. Experimental validation of Monte Carlo dosimetry for therapeutic beta emitters with radiochromic film in a 3D-printed phantom.
Van B; Dewaraja YK; Niedbala JT; Rosebush G; Kazmierski M; Hubers D; Mikell JK; Wilderman SJ
Med Phys; 2023 Jan; 50(1):540-556. PubMed ID: 35983857
[TBL] [Abstract][Full Text] [Related]
18. Study of a spherical phantom for Gamma knife dosimetry.
Zhu D; Austerlitz C; Benhabib S; Mota H; Allison RR; Campos D
J Appl Clin Med Phys; 2010 Apr; 11(2):3130. PubMed ID: 20592697
[TBL] [Abstract][Full Text] [Related]
19. [Validation and analysis of dose distributions in a new and entirely redesigned cobalt-60 stereotactic radiosurgery units].
Nakazawa H; Uchiyama Y; Komori M
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2015 Feb; 71(2):92-8. PubMed ID: 25748009
[TBL] [Abstract][Full Text] [Related]
20. Independent dose validation system for Gamma Knife radiosurgery, using a DICOM-RT interface and Geant4.
Choi HJ; Chung HT; Sohn JW; Min CH
Phys Med; 2018 Jul; 51():117-124. PubMed ID: 29914795
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]