These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 30218973)

  • 41. A novel simulation strategy for stent insertion and deployment in curved coronary bifurcations: comparison of three drug-eluting stents.
    Mortier P; Holzapfel GA; De Beule M; Van Loo D; Taeymans Y; Segers P; Verdonck P; Verhegghe B
    Ann Biomed Eng; 2010 Jan; 38(1):88-99. PubMed ID: 19898936
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Effect of different expansion strategies on coronary stent deployment in a tapered artery.
    Shen X; Ji S; Xie Z; Deng Y
    Technol Health Care; 2017 Jul; 25(S1):21-28. PubMed ID: 28582888
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Deployment of stent grafts in curved aneurysmal arteries: toward a predictive numerical tool.
    Perrin D; Demanget N; Badel P; Avril S; Orgéas L; Geindreau C; Albertini JN
    Int J Numer Method Biomed Eng; 2015 Jan; 31(1):e02698. PubMed ID: 25399927
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Effect of longitudinal anatomical mismatch of stenting on the mechanical environment in human carotid artery with atherosclerotic plaques.
    Fan Z; Liu X; Sun A; Zhang N; Fan Z; Fan Y; Deng X
    Med Eng Phys; 2017 Oct; 48():114-119. PubMed ID: 28826570
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Structural analysis of two different stent configurations.
    Simão M; Ferreira JM; Mora-Rodriguez J; Ramos HM
    Comput Methods Biomech Biomed Engin; 2017 Jun; 20(8):869-883. PubMed ID: 28317393
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Mechanical design of an intracranial stent for treating cerebral aneurysms.
    Shobayashi Y; Tanoue T; Tateshima S; Tanishita K
    Med Eng Phys; 2010 Nov; 32(9):1015-24. PubMed ID: 20675176
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Examination of stent deformation and gap formation after complex stenting of left main coronary artery bifurcations using microfocus computed tomography.
    Murasato Y; Hikichi Y; Horiuchi M
    J Interv Cardiol; 2009 Apr; 22(2):135-44. PubMed ID: 19379472
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Stresses in peripheral arteries following stent placement: a finite element analysis.
    Early M; Lally C; Prendergast PJ; Kelly DJ
    Comput Methods Biomech Biomed Engin; 2009 Feb; 12(1):25-33. PubMed ID: 18821189
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Nitinol Stent Oversizing in Patients Undergoing Popliteal Artery Revascularization: A Finite Element Study.
    Gökgöl C; Diehm N; Nezami FR; Büchler P
    Ann Biomed Eng; 2015 Dec; 43(12):2868-80. PubMed ID: 26101031
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Effect of endovascular stent strut geometry on vascular injury, myointimal hyperplasia, and restenosis.
    Sullivan TM; Ainsworth SD; Langan EM; Taylor S; Snyder B; Cull D; Youkey J; Laberge M
    J Vasc Surg; 2002 Jul; 36(1):143-9. PubMed ID: 12096272
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Design of a metamaterial film with excellent conformability and adhesion for bandage substrates.
    Wang H; Pan C; Zhao H; Wang T; Han Y
    J Mech Behav Biomed Mater; 2021 Dec; 124():104799. PubMed ID: 34536800
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Numerical study of the uniformity of balloon-expandable stent deployment.
    Mortier P; De Beule M; Carlier SG; Van Impe R; Verhegghe B; Verdonck P
    J Biomech Eng; 2008 Apr; 130(2):021018. PubMed ID: 18412505
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Investigation of Stent Implant Mechanics Using Linear Analytical and Computational Approach.
    Yang H; Fortier A; Horne K; Mohammad A; Banerjee S; Han HC
    Cardiovasc Eng Technol; 2017 Mar; 8(1):81-90. PubMed ID: 28160266
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Finite element analysis and stent design: Reduction of dogboning.
    De Beule M; Van Impe R; Verhegghe B; Segers P; Verdonck P
    Technol Health Care; 2006; 14(4-5):233-41. PubMed ID: 17065746
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Mechanical behavior of coronary stents investigated through the finite element method.
    Migliavacca F; Petrini L; Colombo M; Auricchio F; Pietrabissa R
    J Biomech; 2002 Jun; 35(6):803-11. PubMed ID: 12021000
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Biomechanical analysis of tracheal stent during cough reflex.
    Hassani K; Kazem Golmohammadi M
    Proc Inst Mech Eng H; 2022 Sep; 236(9):1449-1456. PubMed ID: 35894299
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method.
    Wang WQ; Liang DK; Yang DZ; Qi M
    J Biomech; 2006; 39(1):21-32. PubMed ID: 16271584
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Numerical simulation on the effects of drug-eluting stents with different bending angles on hemodynamics and drug distribution.
    Chen Y; Xiong Y; Jiang W; Wong MS; Yan F; Wang Q; Fan Y
    Med Biol Eng Comput; 2016 Dec; 54(12):1859-1870. PubMed ID: 27048391
    [TBL] [Abstract][Full Text] [Related]  

  • 59. A numerical study on the application of the functionally graded materials in the stent design.
    Khosravi A; Bahreinizad H; Bani MS; Karimi A
    Mater Sci Eng C Mater Biol Appl; 2017 Apr; 73():182-188. PubMed ID: 28183596
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Coronary in-stent restenosis: predisposing clinical and stent-related factors, diagnostic performance and analyses of inaccuracies in 320-row computed tomography angiography.
    Wan YL; Tsay PK; Chen CC; Juan YH; Huang YC; Chan WH; Wen MS; Hsieh IC
    Int J Cardiovasc Imaging; 2016 Jun; 32 Suppl 1():105-15. PubMed ID: 27106698
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.