487 related articles for article (PubMed ID: 30219148)
21. A combination of three-dimensional printing and computer-assisted virtual surgical procedure for preoperative planning of acetabular fracture reduction.
Zeng C; Xing W; Wu Z; Huang H; Huang W
Injury; 2016 Oct; 47(10):2223-2227. PubMed ID: 27372187
[TBL] [Abstract][Full Text] [Related]
22. Long bone fracture reduction and deformity correction using the hexapod external fixator with a new method: a feasible study and preliminary results.
Liu Y; Li H; Liu J; Zhang X; Yushan M; Liu Z; Ma C; Yusufu A
BMC Musculoskelet Disord; 2021 Feb; 22(1):221. PubMed ID: 33627096
[TBL] [Abstract][Full Text] [Related]
23. High tibial osteotomy with use of the Taylor Spatial Frame external fixator for osteoarthritis of the knee.
Viskontas DG; MacLeod MD; Sanders DW
Can J Surg; 2006 Aug; 49(4):245-50. PubMed ID: 16948882
[TBL] [Abstract][Full Text] [Related]
24. Preliminary application of three-dimension printing technology in surgical management of bicondylar tibial plateau fractures.
Nie W; Gu F; Wang Z; Wu R; Yue Y; Shao A
Injury; 2019 Feb; 50(2):476-483. PubMed ID: 30580928
[TBL] [Abstract][Full Text] [Related]
25. The use of a circular external skeletal fixation device for the management of long bone osteotomies in large ruminants: an experimental study.
Aithal HP; Singh GR; Hoque M; Maiti SK; Kinjavdekar P; Pawde AM; Setia HC;
J Vet Med A Physiol Pathol Clin Med; 2004 Aug; 51(6):284-93. PubMed ID: 15485564
[TBL] [Abstract][Full Text] [Related]
26. Treatment of hypertrophic distal tibia nonunion and early malunion with callus distraction.
Schoenleber SJ; Hutson JJ
Foot Ankle Int; 2015 Apr; 36(4):400-7. PubMed ID: 25358806
[TBL] [Abstract][Full Text] [Related]
27. Bone tissue repair in patients with open diaphyseal tibial fracture treated with biplanar external fixation or reamed locked intramedullary nailing.
Rodrigues FL; de Abreu LC; Valenti VE; Valente AL; da Costa Pereira Cestari R; Pohl PH; Rodrigues LM
Injury; 2014 Nov; 45 Suppl 5():S32-5. PubMed ID: 25528622
[TBL] [Abstract][Full Text] [Related]
28. Intraoperative acute correction versus postoperative gradual correction for tibial shaft fractures with multiplanar posttraumatic deformities using the hexapod external fixator.
Liu Y; Cai F; Liu K; Zhang X; Li H; Fu X; Zhang T; Yusufu A
BMC Musculoskelet Disord; 2021 Sep; 22(1):803. PubMed ID: 34537029
[TBL] [Abstract][Full Text] [Related]
29. Distraction osteogenesis for the treatment of post traumatic complications using a conventional external fixator. A novel technique.
Sangkaew C
Injury; 2005 Jan; 36(1):185-93. PubMed ID: 15589939
[TBL] [Abstract][Full Text] [Related]
30. [Callus Distraction in the Treatment of Post-Traumatic Defects of the Femur and Tibia].
Veselý R; Procházka V
Acta Chir Orthop Traumatol Cech; 2016; 83(6):388-392. PubMed ID: 28026734
[TBL] [Abstract][Full Text] [Related]
31. Supramalleolar osteotomy using circular external fixation with six-axis deformity correction of the distal tibia.
Horn DM; Fragomen AT; Rozbruch SR
Foot Ankle Int; 2011 Oct; 32(10):986-93. PubMed ID: 22224328
[TBL] [Abstract][Full Text] [Related]
32. Treatment of malunions and mal-nonunions of the femur and tibia by detailed preoperative planning and the Ilizarov techniques.
Paley D; Chaudray M; Pirone AM; Lentz P; Kautz D
Orthop Clin North Am; 1990 Oct; 21(4):667-91. PubMed ID: 2216401
[TBL] [Abstract][Full Text] [Related]
33. 3D-printed models improve surgical planning for correction of severe postburn ankle contracture with an external fixator.
Chen Y; Niu Z; Jiang W; Tao R; Lei Y; Guo L; Zhang K; Xia W; Song B; Huang L; Zhang Q; Han Y
J Zhejiang Univ Sci B; 2021 Oct; 22(10):866-875. PubMed ID: 34636189
[TBL] [Abstract][Full Text] [Related]
34. A novel combination of computer-assisted reduction technique and three dimensional printed patient-specific external fixator for treatment of tibial fractures.
Qiao F; Li D; Jin Z; Hao D; Liao Y; Gong S
Int Orthop; 2016 Apr; 40(4):835-41. PubMed ID: 26239534
[TBL] [Abstract][Full Text] [Related]
35. [Temporary external fixation in the correction of non articular mal-unions of the distal radius].
Voche P; Dautel G; Dap F; Merle M; Ninou M
Rev Chir Orthop Reparatrice Appar Mot; 1999 Mar; 85(1):18-23. PubMed ID: 10327463
[TBL] [Abstract][Full Text] [Related]
36. Correction of proximal tibia varus with external fixation.
Ashfaq K; Fragomen AT; Nguyen JT; Rozbruch SR
J Knee Surg; 2012 Nov; 25(5):375-84. PubMed ID: 23150346
[TBL] [Abstract][Full Text] [Related]
37. Distal leg fractures: How critical is the fibular fracture and its fixation?
Bonnevialle P; Lafosse JM; Pidhorz L; Poichotte A; Asencio G; Dujardin F;
Orthop Traumatol Surg Res; 2010 Oct; 96(6):667-73. PubMed ID: 20851076
[TBL] [Abstract][Full Text] [Related]
38. [Computer-assisted kinematic 2D and 3D navigation in medial opening-wedge high-tibial valgus osteotomy].
Okál F; Hart R; Komzák M; Safi A
Acta Chir Orthop Traumatol Cech; 2013; 80(2):159-64. PubMed ID: 23562262
[TBL] [Abstract][Full Text] [Related]
39. Opposite cortical fracture in high tibial osteotomy: lateral closing compared to the medial opening-wedge technique.
van Raaij TM; Brouwer RW; de Vlieger R; Reijman M; Verhaar JA
Acta Orthop; 2008 Aug; 79(4):508-14. PubMed ID: 18766484
[TBL] [Abstract][Full Text] [Related]
40. Conventional plate fixation method versus pre-operative virtual simulation and three-dimensional printing-assisted contoured plate fixation method in the treatment of anterior pelvic ring fracture.
Hung CC; Li YT; Chou YC; Chen JE; Wu CC; Shen HC; Yeh TT
Int Orthop; 2019 Feb; 43(2):425-431. PubMed ID: 29725736
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]