146 related articles for article (PubMed ID: 30223773)
21. Effect of thermal softening of double-lumen endobronchial tubes on postoperative sore throat in patients with prior SARS-CoV-2 infection: a randomized controlled trial.
Yan W; Cai J; Zhu C; Chen Y; Fang J; Xu H; Zheng X; Zhou Y; Xie Y; Zhang M; Shu S
BMC Anesthesiol; 2023 Dec; 23(1):403. PubMed ID: 38062363
[TBL] [Abstract][Full Text] [Related]
22. Intubation with VivaSight or conventional left-sided double-lumen tubes: a randomized trial.
Schuepbach R; Grande B; Camen G; Schmidt AR; Fischer H; Sessler DI; Seifert B; Spahn DR; Ruetzler K
Can J Anaesth; 2015 Jul; 62(7):762-9. PubMed ID: 25663254
[TBL] [Abstract][Full Text] [Related]
23. A modified technique to improve the outcome of intubation with a left-sided double-lumen endobronchial tube.
Hsu HT; Chou SH; Chou CY; Tseng KY; Kuo YW; Chen MC; Cheng KI
BMC Anesthesiol; 2014; 14():72. PubMed ID: 25206313
[TBL] [Abstract][Full Text] [Related]
24. Electrical impedance tomography to confirm correct placement of double-lumen tube: a feasibility study.
Steinmann D; Stahl CA; Minner J; Schumann S; Loop T; Kirschbaum A; Priebe HJ; Guttmann J
Br J Anaesth; 2008 Sep; 101(3):411-8. PubMed ID: 18559350
[TBL] [Abstract][Full Text] [Related]
25. Augmentation of curved tip of left-sided double-lumen tubes to reduce right bronchial misplacement: A randomized controlled trial.
Seo JH; Yoon S; Min SH; Row HS; Bahk JH
PLoS One; 2019; 14(1):e0210711. PubMed ID: 30645611
[TBL] [Abstract][Full Text] [Related]
26. Comparison of the accuracy of three methods measured the length of the right main stem bronchus by chest computed tomography as a guide to the use of right sided double-lumen tube.
Liu Z; Liu M; Zhao L; Qi X; Yu Y; Liang S; Yang X; Ma Z
BMC Anesthesiol; 2022 Aug; 22(1):264. PubMed ID: 35982403
[TBL] [Abstract][Full Text] [Related]
27. Comparison of displacement of polyvinyl chloride and silicone leftsided double-lumen tubes during lateral positioning.
Kwon NK; Jung SM; Park SJ; Han Y
Korean J Anesthesiol; 2019 Feb; 72(1):32-38. PubMed ID: 29921088
[TBL] [Abstract][Full Text] [Related]
28. [Comparison of the double-lumen endotracheal tube and the Arndt bronchial blocker used by inexperienced anesthesiologists in right- and left-sided thoracic surgery].
Vilà E; García Guasch R; Ibáñez C; Rodríguez M; Martínez L; López de Castro P
Rev Esp Anestesiol Reanim; 2007 Dec; 54(10):602-7. PubMed ID: 18200995
[TBL] [Abstract][Full Text] [Related]
29. Comparison of Arndt-endobronchial blocker plus laryngeal mask airway with left-sided double-lumen endobronchial tube in one-lung ventilation in thoracic surgery in the morbidly obese.
Zhang ZJ; Zheng ML; Nie Y; Niu ZQ
Braz J Med Biol Res; 2017 Dec; 51(2):e6825. PubMed ID: 29267506
[TBL] [Abstract][Full Text] [Related]
30. Misplacement of left-sided double-lumen tubes into the right mainstem bronchus: incidence, risk factors and blind repositioning techniques.
Seo JH; Bae JY; Kim HJ; Hong DM; Jeon Y; Bahk JH
BMC Anesthesiol; 2015 Oct; 15():157. PubMed ID: 26511934
[TBL] [Abstract][Full Text] [Related]
31. Incidental left main bronchus obstruction during left-sided double-lumen tube intubation of a patient with an unrecognized tracheal bronchus: A case report.
Cho HB; Kim HJ; Gong HY; Kim MG; Kim SH
Medicine (Baltimore); 2016 Dec; 95(52):e5674. PubMed ID: 28033257
[TBL] [Abstract][Full Text] [Related]
32. Placement of left double-lumen endobronchial tubes with or without a stylet.
Lieberman D; Littleford J; Horan T; Unruh H
Can J Anaesth; 1996 Mar; 43(3):238-42. PubMed ID: 8829862
[TBL] [Abstract][Full Text] [Related]
33. Comparison of left double lumen tube and y-shaped and double-ended bronchial blocker for one lung ventilation in thoracic surgery-a randomised controlled clinical trial.
Risse J; Szeder K; Schubert AK; Wiesmann T; Dinges HC; Feldmann C; Wulf H; Meggiolaro KM
BMC Anesthesiol; 2022 Apr; 22(1):92. PubMed ID: 35366801
[TBL] [Abstract][Full Text] [Related]
34. [Analysis of the association between double-lumen endobronchial tube and inner diameter of the left main bronchus].
Cui JX; Zhao GD; Huang WQ
Di Yi Jun Yi Da Xue Xue Bao; 2005 Jul; 25(7):799-801. PubMed ID: 16027071
[TBL] [Abstract][Full Text] [Related]
35. Effect of prophylactic benzydamine hydrochloride on postoperative sore throat and hoarseness after tracheal intubation using a double-lumen endobronchial tube: a randomized controlled trial.
Chang JE; Min SW; Kim CS; Han SH; Kwon YS; Hwang JY
Can J Anaesth; 2015 Oct; 62(10):1097-103. PubMed ID: 26149601
[TBL] [Abstract][Full Text] [Related]
36. Chest Computed Tomography Image for Accurately Predicting the Optimal Insertion Depth of Left-Sided Double-Lumen Tube.
Liu Z; Zhao L; Jia Q; Yang X; Liang SJ; He W
J Cardiothorac Vasc Anesth; 2018 Apr; 32(2):855-859. PubMed ID: 29221981
[TBL] [Abstract][Full Text] [Related]
37. Effects of Thermal Softening of Double-Lumen Endobronchial Tubes on the Prevention of Postoperative Sore Throat in Smokers: A Randomized Controlled Trial.
Bi X; Wen J; Chen Q; Zhang X
J Cardiothorac Vasc Anesth; 2022 Aug; 36(8 Pt B):3109-3113. PubMed ID: 35537970
[TBL] [Abstract][Full Text] [Related]
38. Is flexible bronchoscopy necessary to confirm the position of double-lumen tubes before thoracic surgery?
de Bellis M; Accardo R; Di Maio M; La Manna C; Rossi GB; Pace MC; Romano V; Rocco G
Eur J Cardiothorac Surg; 2011 Oct; 40(4):912-6. PubMed ID: 21802958
[TBL] [Abstract][Full Text] [Related]
39. Comparison of a tube-holder (Rescuefix) versus tape-tying for minimizing double-lumen tube displacement during lateral positioning in thoracic surgery: A prospective, randomized controlled study.
Byun SH; Kang SH; Kim JH; Ryu T; Kim BJ; Jung JY
Medicine (Baltimore); 2016 Aug; 95(31):e4486. PubMed ID: 27495093
[TBL] [Abstract][Full Text] [Related]
40. Margin of safety in positioning modern double-lumen endotracheal tubes.
Benumof JL; Partridge BL; Salvatierra C; Keating J
Anesthesiology; 1987 Nov; 67(5):729-38. PubMed ID: 3674473
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]