These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

325 related articles for article (PubMed ID: 30231916)

  • 21. Development of a Prototype Overground Pelvic Obliquity Support Robot for Rehabilitation of Hemiplegia Gait.
    Hwang S; Lee S; Shin D; Baek I; Ham S; Kim W
    Sensors (Basel); 2022 Mar; 22(7):. PubMed ID: 35408083
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Biomechanical effects of robot assisted walking on knee joint kinematics and muscle activation pattern.
    Thangavel P; Vidhya S; Li J; Chew E; Bezerianos A; Yu H
    IEEE Int Conf Rehabil Robot; 2017 Jul; 2017():252-257. PubMed ID: 28813827
    [TBL] [Abstract][Full Text] [Related]  

  • 23. An assistance approach for a powered knee exoskeleton during level walking and the effects on metabolic cost.
    Jang J; Lim B; Shim Y
    Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():6216-6219. PubMed ID: 31947263
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Evaluating the effectiveness of an active strap for wearable robot: A Mechanical and Physiological Study.
    Lee S; In H
    Annu Int Conf IEEE Eng Med Biol Soc; 2023 Jul; 2023():1-6. PubMed ID: 38083124
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The association between fear of falling and smoothness of lower trunk oscillation in gait varies according to gait speed in community-dwelling older adults.
    Asai T; Misu S; Sawa R; Doi T; Yamada M
    J Neuroeng Rehabil; 2017 Jan; 14(1):5. PubMed ID: 28103907
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Wearable hip-assist robot modulates cortical activation during gait in stroke patients: a functional near-infrared spectroscopy study.
    Lee SH; Lee HJ; Shim Y; Chang WH; Choi BO; Ryu GH; Kim YH
    J Neuroeng Rehabil; 2020 Oct; 17(1):145. PubMed ID: 33121535
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Gait Training Using the Honda Walking Assistive Device
    Koseki K; Mutsuzaki H; Yoshikawa K; Endo Y; Maezawa T; Takano H; Yozu A; Kohno Y
    Medicina (Kaunas); 2019 Mar; 55(3):. PubMed ID: 30875846
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Visual guidance can help with the use of a robotic exoskeleton during human walking.
    Kim M; Jeong H; Kantharaju P; Yoo D; Jacobson M; Shin D; Han C; Patton JL
    Sci Rep; 2022 Mar; 12(1):3881. PubMed ID: 35273244
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Influence of Varied Load Assistance with Exoskeleton-Type Robotic Device on Gait Rehabilitation in Healthy Adult Men.
    Tanaka T; Matsumura R; Miura T
    Int J Environ Res Public Health; 2022 Aug; 19(15):. PubMed ID: 35955068
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The Wearable Lower Limb Rehabilitation Exoskeleton Kinematic Analysis and Simulation.
    Li J; Peng J; Lu Z; Huang K
    Biomed Res Int; 2022; 2022():5029663. PubMed ID: 36072470
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Abnormal gait pattern emerges during curved trajectories in high-functioning Parkinsonian patients walking in line at normal speed.
    Turcato AM; Godi M; Giardini M; Arcolin I; Nardone A; Giordano A; Schieppati M
    PLoS One; 2018; 13(5):e0197264. PubMed ID: 29750815
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effect of wearable chair on gait, balance, and discomfort of new users during level walking with anterior loads.
    Li YY; Gan J
    J Safety Res; 2023 Dec; 87():27-37. PubMed ID: 38081701
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Effect of timing of hip extension assistance during loaded walking with a soft exosuit.
    Ding Y; Panizzolo FA; Siviy C; Malcolm P; Galiana I; Holt KG; Walsh CJ
    J Neuroeng Rehabil; 2016 Oct; 13(1):87. PubMed ID: 27716439
    [TBL] [Abstract][Full Text] [Related]  

  • 34. From normal to fast walking: Impact of cadence and stride length on lower extremity joint moments.
    Ardestani MM; Ferrigno C; Moazen M; Wimmer MA
    Gait Posture; 2016 May; 46():118-25. PubMed ID: 27131188
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Wearable tubing assistive walking device immediately enhances gait parameters in subjects with stroke: A randomized controlled study.
    Lee SM; Cynn HS; Yi CH; Yoon TL; Lee JH
    NeuroRehabilitation; 2017; 40(1):99-107. PubMed ID: 27935557
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Gait adaptability training improves obstacle avoidance and dynamic stability in patients with cerebellar degeneration.
    Fonteyn EM; Heeren A; Engels JJ; Boer JJ; van de Warrenburg BP; Weerdesteyn V
    Gait Posture; 2014; 40(1):247-51. PubMed ID: 24786476
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Wearable Biofeedback System to Induce Desired Walking Speed in Overground Gait Training.
    Zhang H; Yin Y; Chen Z; Zhang Y; Rao AK; Guo Y; Zanotto D
    Sensors (Basel); 2020 Jul; 20(14):. PubMed ID: 32708450
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Single-stride exposure to pulse torque assistance provided by a robotic exoskeleton at the hip and knee joints.
    McGrath RL; Sergi F
    IEEE Int Conf Rehabil Robot; 2019 Jun; 2019():874-879. PubMed ID: 31374740
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A Wearable Biofeedback Device to Increase Gait Swing Time Could Have Positive Effects on Gait among Older Adults.
    Giraldo-Pedroza A; Lee WC; Lam WK; Coman R; Alici G
    Sensors (Basel); 2021 Dec; 22(1):. PubMed ID: 35009646
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Wearable robotic exoskeleton for overground gait training in sub-acute and chronic hemiparetic stroke patients: preliminary results.
    Molteni F; Gasperini G; Gaffuri M; Colombo M; Giovanzana C; Lorenzon C; Farina N; Cannaviello G; Scarano S; Proserpio D; Liberali D; Guanziroli E
    Eur J Phys Rehabil Med; 2017 Oct; 53(5):676-684. PubMed ID: 28118698
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 17.