These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 30246313)

  • 1. New three-dimensional/four-dimensional volume rendering imaging software for detecting the abnormally invasive placenta.
    Aryananda RA; Akbar A; Wardhana MP; Gumilar KE; Wicaksono B; Ernawati E; Sulistyono A; Aditiawarman A; Joewono HT; Dachlan EG; Parange A; Dekker GA
    J Clin Ultrasound; 2019 Jan; 47(1):9-13. PubMed ID: 30246313
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Diagnostic accuracy of ultrasound in detecting the depth of invasion in women at risk of abnormally invasive placenta: A prospective longitudinal study.
    Cali G; Forlani F; Timor-Trisch I; Palacios-Jaraquemada J; Foti F; Minneci G; Flacco ME; Manzoli L; Familiari A; Pagani G; Scambia G; D'Antonio F
    Acta Obstet Gynecol Scand; 2018 Oct; 97(10):1219-1227. PubMed ID: 29797715
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Diagnostic accuracy of ultrasound in detecting the severity of abnormally invasive placentation: a systematic review and meta-analysis.
    Pagani G; Cali G; Acharya G; Trisch IT; Palacios-Jaraquemada J; Familiari A; Buca D; Manzoli L; Flacco ME; Fanfani F; Liberati M; Scambia G; D'antonio F
    Acta Obstet Gynecol Scand; 2018 Jan; 97(1):25-37. PubMed ID: 28963728
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Three-dimensional volume rendering ultrasound for assessing placenta accreta spectrum severity and discriminating it from simple scar dehiscence.
    Adu-Bredu TK; Ridwan R; Aditiawarman A; Ariani G; Collins SL; Aryananda RA
    Am J Obstet Gynecol MFM; 2024 Apr; 6(4):101321. PubMed ID: 38460827
    [TBL] [Abstract][Full Text] [Related]  

  • 5. 3D power Doppler in the evaluation of abnormally invasive placenta.
    Calì G; Foti F; Minneci G
    J Perinat Med; 2017 Aug; 45(6):701-709. PubMed ID: 28489561
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accreta placentation: a systematic review of prenatal ultrasound imaging and grading of villous invasiveness.
    Jauniaux E; Collins SL; Jurkovic D; Burton GJ
    Am J Obstet Gynecol; 2016 Dec; 215(6):712-721. PubMed ID: 27473003
    [TBL] [Abstract][Full Text] [Related]  

  • 7. 3D volume contrast imaging (VCI) for the visualization of placenta previa increta and uterine wall thickness in a dichorionic twin pregnancy.
    Henrich W; Stupin JH
    Ultraschall Med; 2011 Aug; 32(4):406-11. PubMed ID: 21080310
    [TBL] [Abstract][Full Text] [Related]  

  • 8. First-trimester detection of abnormally invasive placenta in high-risk women: systematic review and meta-analysis.
    D'Antonio F; Timor-Tritsch IE; Palacios-Jaraquemada J; Monteagudo A; Buca D; Forlani F; Minneci G; Foti F; Manzoli L; Liberati M; Acharya G; Calì G
    Ultrasound Obstet Gynecol; 2018 Feb; 51(2):176-183. PubMed ID: 28833750
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Lower uterine segment placental thickness in women with abnormally invasive placenta.
    Bhide A; Laoreti A; Kaelin Agten A; Papageorghiou A; Khalil A; Uprichard J; Thilaganathan B; Chandraharan E
    Acta Obstet Gynecol Scand; 2019 Jan; 98(1):95-100. PubMed ID: 29978457
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Diagnostic accuracy of first-trimester ultrasound in detecting abnormally invasive placenta in high-risk women with placenta previa.
    Cali G; Forlani F; Foti F; Minneci G; Manzoli L; Flacco ME; Buca D; Liberati M; Scambia G; D'Antonio F
    Ultrasound Obstet Gynecol; 2018 Aug; 52(2):258-264. PubMed ID: 29532529
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of tramline sign for prenatal diagnosis of abnormally invasive placenta using three-dimensional ultrasound and Crystal Vue rendering technology.
    Dall'Asta A; Shah H; Masini G; Paramasivam G; Yazbek J; Bourne T; Lees CC
    Ultrasound Obstet Gynecol; 2018 Sep; 52(3):403-404. PubMed ID: 29205615
    [No Abstract]   [Full Text] [Related]  

  • 12. Value of Crystal Vue technique in detecting the placenta accreta spectrum located in c-section scar area.
    Chen S; Chen Q; Du X; Chen S; Li W; Chen S
    Med Ultrason; 2020 Nov; 22(4):438-444. PubMed ID: 32905564
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prenatal sonography can predict degree of placental invasion.
    Chalubinski KM; Pils S; Klein K; Seemann R; Speiser P; Langer M; Ott J
    Ultrasound Obstet Gynecol; 2013 Nov; 42(5):518-24. PubMed ID: 23471888
    [TBL] [Abstract][Full Text] [Related]  

  • 14. First-trimester prediction of surgical outcome in abnormally invasive placenta using the cross-over sign.
    Calì G; Forlani F; Minneci G; Foti F; Di Liberto S; Familiari A; Scambia G; D'Antonio F
    Ultrasound Obstet Gynecol; 2018 Feb; 51(2):184-188. PubMed ID: 28233462
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Changes in ultrasonography indicators of abnormally invasive placenta during pregnancy.
    Calì G; Timor-Trisch IE; Palacios-Jaraquemada J; Monteaugudo A; Forlani F; Minneci G; Foti F; Buca D; Familiari A; Scambia G; Liberati M; D'Antonio F
    Int J Gynaecol Obstet; 2018 Mar; 140(3):319-325. PubMed ID: 29197083
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Expert opinion: Stepwise ultrasound assessment of suspected placenta accreta spectrum using 2D, Doppler and 3D imaging.
    Srinivasan D; Shaw CJ; Dall'Asta A; Papanikoloau K; Yazbek J; Lees CC
    Eur J Obstet Gynecol Reprod Biol; 2022 Mar; 270():181-189. PubMed ID: 35085956
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Role of three-dimensional power Doppler in the antenatal diagnosis of placenta accreta: comparison with gray-scale and color Doppler techniques.
    Shih JC; Palacios Jaraquemada JM; Su YN; Shyu MK; Lin CH; Lin SY; Lee CN
    Ultrasound Obstet Gynecol; 2009 Feb; 33(2):193-203. PubMed ID: 19173239
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of prenatal diagnosis of abnormally invasive placenta on maternal outcome: systematic review and meta-analysis.
    Buca D; Liberati M; Calì G; Forlani F; Caisutti C; Flacco ME; Manzoli L; Familiari A; Scambia G; D'Antonio F
    Ultrasound Obstet Gynecol; 2018 Sep; 52(3):304-309. PubMed ID: 29660186
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Morbidly adherent placenta: evaluation of ultrasound diagnostic criteria and differentiation of placenta accreta from percreta.
    Calì G; Giambanco L; Puccio G; Forlani F
    Ultrasound Obstet Gynecol; 2013 Apr; 41(4):406-12. PubMed ID: 23288834
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of the diagnostic accuracy of a combination of first-trimester ultrasound and maternal demographic characteristics for detecting abnormally invasive placenta.
    Sahin E; Madendag Y; Eraslan Sahin M; Col Madendag I; Kirlangic MM
    Eur J Obstet Gynecol Reprod Biol; 2022 Jan; 268():1-6. PubMed ID: 34788719
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.