These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 30246970)

  • 1. [Adaptability of Different Nebulizer Systems to Different Silicon Chemical Forms for Gasoline in Inductively Coupled Plasma Optical Emission Spectrometry].
    Zhao Y; Chen XY; Xu DY; Zhang SY; Liao J
    Guang Pu Xue Yu Guang Pu Fen Xi; 2016 Oct; 36(10):3303-7. PubMed ID: 30246970
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of Silicon in Gasoline by Directly Measuring under Organic Phase Using Inductively Coupled Plasma Optical Emission Spectroscopy.
    Zhang WM; Wen H; Lü HM; Liu HQ; Lin ZS; Wang RH
    Guang Pu Xue Yu Guang Pu Fen Xi; 2015 Mar; 35(3):760-4. PubMed ID: 26117893
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accurate determination of sulfur in gasoline and related fuel samples using isotope dilution ICP-MS with direct sample injection and microwave-assisted digestion.
    Heilmann J; Boulyga SF; Heumann KG
    Anal Bioanal Chem; 2004 Sep; 380(2):190-7. PubMed ID: 15232670
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A large bore-direct injection high efficiency nebulizer for inductively coupled plasma spectrometry.
    Acon BW; McLean JA; Montaser A
    Anal Chem; 2000 Apr; 72(8):1885-93. PubMed ID: 10784158
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ultratrace and isotope analysis of long-lived radionuclides by inductively coupled plasma quadrupole mass spectrometry using a direct injection high efficiency nebulizer.
    Becker JS; Dietze HJ; McLean JA; Montaser A
    Anal Chem; 1999 Aug; 71(15):3077-84. PubMed ID: 21662899
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Alcohol and metal determination in alcoholic beverages through high-temperature liquid-chromatography coupled to an inductively coupled plasma atomic emission spectrometer.
    Terol A; Paredes E; Maestre SE; Prats S; Todolí JL
    J Chromatogr A; 2011 Jun; 1218(22):3439-46. PubMed ID: 21507407
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Determination of chlorine in gasoline by inductively coupled plasma atomic emission spectrometry].
    Zhao Y; Chen XY; Xu DY; Zhang SY; Chen ZY
    Guang Pu Xue Yu Guang Pu Fen Xi; 2014 Dec; 34(12):3406-10. PubMed ID: 25881448
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A direct injection high-efficiency nebulizer for inductively coupled plasma mass spectrometry.
    McLean JA; Zhang H; Montaser A
    Anal Chem; 1998 Mar; 70(5):1012-20. PubMed ID: 9511474
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simultaneous Determination of Impurity Elements in N-Methyl-2- Pyrrolidone (NMP) with Direct Injection Inductively Coupled Plasma Optical Emission Spectrometry.
    Nie XD; Fu L
    Guang Pu Xue Yu Guang Pu Fen Xi; 2017; 37(3):910-3. PubMed ID: 30160419
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Investigation of the direct hydride generation nebulizer for the determination of arsenic, antimony and selenium in inductively coupled plasma optical emission spectrometry.
    Rojas I; Murillo M; Carrión N; Chirinos J
    Anal Bioanal Chem; 2003 May; 376(1):110-7. PubMed ID: 12677344
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of depleted uranium in urine via isotope ratio measurements using large-bore direct injection high efficiency nebulizer-inductively coupled plasma mass spectrometry.
    Westphal CS; McLean JA; Hakspiel SJ; Jackson WE; McClain DE; Montaser A
    Appl Spectrosc; 2004 Sep; 58(9):1044-50. PubMed ID: 15479520
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Determination of SiO2 in Groundwater and Mineral Water by Inductively Coupled Plasma-Atomic Emission Spectrometry].
    Liu BB; Han M; Jia N; Liu SH
    Guang Pu Xue Yu Guang Pu Fen Xi; 2015 May; 35(5):1388-91. PubMed ID: 26415465
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of As, Se, and Hg in fuel samples by in-chamber chemical vapor generation ICP OES using a Flow Blurring® multinebulizer.
    García M; Aguirre MÁ; Canals A
    Anal Bioanal Chem; 2017 Sep; 409(23):5481-5490. PubMed ID: 28687885
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Sensitivity improvement in ICP MS analysis of fuels and light petroleum matrices using a microflow nebulizer and heated spray chamber sample introduction.
    Caumette G; Lienemann CP; Merdrignac I; Paucot H; Bouyssiere B; Lobinski R
    Talanta; 2009 Dec; 80(2):1039-43. PubMed ID: 19836594
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mixed-gas inductively coupled plasma atomic emission spectrometry using a direct injection high efficiency nebulizer.
    Chirinos JR; Kahen K; O'Brien SA; Montaser A
    Anal Bioanal Chem; 2002 Jan; 372(1):128-35. PubMed ID: 11939181
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High precision measurement of silicon in naphthas by ICP-OES using isooctane as diluent.
    Gazulla MF; Rodrigo M; Orduña M; Ventura MJ; Andreu C
    Talanta; 2017 Mar; 164():563-569. PubMed ID: 28107973
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Application of a microwave-based desolvation system for multi-elemental analysis of wine by inductively coupled plasma based techniques.
    Grindlay G; Mora J; Maestre S; Gras L
    Anal Chim Acta; 2008 Nov; 629(1-2):24-37. PubMed ID: 18940318
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dual nebulizer sample introduction system for simultaneous determination of volatile elemental hydrides and other elements.
    Gómez LR; Márquez GD; Chirinos JR
    Anal Bioanal Chem; 2006 Sep; 386(1):188-95. PubMed ID: 16868730
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Application of cotton as a solid phase extraction sorbent for on-line preconcentration of copper in water samples prior to inductively coupled plasma optical emission spectrometry determination.
    Faraji M; Yamini Y; Shariati S
    J Hazard Mater; 2009 Jul; 166(2-3):1383-8. PubMed ID: 19157691
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of silicon in high-silicon electrical steel by ICP-AES with on-line sample electrolytic dissolution.
    Aimoto M; Kondo H; Ono A
    Anal Sci; 2007 Dec; 23(12):1367-71. PubMed ID: 18071220
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.