167 related articles for article (PubMed ID: 30248641)
1. Construction and application of amperometric sarcosine biosensor based on SOxNPs/AuE for determination of prostate cancer.
Kumar P; Narwal V; Jaiwal R; Pundir CS
Biosens Bioelectron; 2018 Dec; 122():140-146. PubMed ID: 30248641
[TBL] [Abstract][Full Text] [Related]
2. Fabrication of an amperometric sarcosine biosensor based on sarcosine oxidase/chitosan/CuNPs/c-MWCNT/Au electrode for detection of prostate cancer.
Narwal V; Kumar P; Joon P; Pundir CS
Enzyme Microb Technol; 2018 Jun; 113():44-51. PubMed ID: 29602386
[TBL] [Abstract][Full Text] [Related]
3. Fabrication of an improved amperometric creatinine biosensor based on enzymes nanoparticles bound to Au electrode.
Kumar P; Kamboj M; Jaiwal R; Pundir CS
Biomarkers; 2019 Dec; 24(8):739-749. PubMed ID: 31617777
[TBL] [Abstract][Full Text] [Related]
4. An improved amperometric creatinine biosensor based on nanoparticles of creatininase, creatinase and sarcosine oxidase.
Kumar P; Jaiwal R; Pundir CS
Anal Biochem; 2017 Nov; 537():41-49. PubMed ID: 28870830
[TBL] [Abstract][Full Text] [Related]
5. An amperometric glutamate biosensor based on immobilization of glutamate oxidase onto carboxylated multiwalled carbon nanotubes/gold nanoparticles/chitosan composite film modified Au electrode.
Batra B; Pundir CS
Biosens Bioelectron; 2013 Sep; 47():496-501. PubMed ID: 23628843
[TBL] [Abstract][Full Text] [Related]
6. Immobilization of creatininase, creatinase and sarcosine oxidase on iron oxide nanoparticles/chitosan-g-polyaniline modified Pt electrode for detection of creatinine.
Yadav S; Devi R; Bhar P; Singhla S; Pundir CS
Enzyme Microb Technol; 2012 Apr; 50(4-5):247-54. PubMed ID: 22418265
[TBL] [Abstract][Full Text] [Related]
7. An amperometric H
Narwal V; Yadav N; Thakur M; Pundir CS
Biosci Rep; 2017 Aug; 37(4):. PubMed ID: 28550154
[TBL] [Abstract][Full Text] [Related]
8. An improved enzyme nanoparticles based amperometric pyruvate biosensor for detection of pyruvate in serum.
Malik M; Chaudhary R; Pundir CS
Enzyme Microb Technol; 2019 Apr; 123():30-38. PubMed ID: 30686348
[TBL] [Abstract][Full Text] [Related]
9. Construction of an amperometric bilirubin biosensor based on covalent immobilization of bilirubin oxidase onto zirconia coated silica nanoparticles/chitosan hybrid film.
Batra B; Lata S; Sunny ; Rana JS; Pundir CS
Biosens Bioelectron; 2013 Jun; 44():64-9. PubMed ID: 23395724
[TBL] [Abstract][Full Text] [Related]
10. An improved amperometric triglyceride biosensor based on co-immobilization of nanoparticles of lipase, glycerol kinase and glycerol 3-phosphate oxidase onto pencil graphite electrode.
Narwal V; Pundir CS
Enzyme Microb Technol; 2017 May; 100():11-16. PubMed ID: 28284306
[TBL] [Abstract][Full Text] [Related]
11. An electrochemical sulfite biosensor based on gold coated magnetic nanoparticles modified gold electrode.
Rawal R; Chawla S; Pundir CS
Biosens Bioelectron; 2012 Jan; 31(1):144-50. PubMed ID: 22035973
[TBL] [Abstract][Full Text] [Related]
12. Fabrication and application of an amperometric lysine biosensor based on covalently immobilized lysine oxidase nanoparticles onto Au electrode.
Nohwal B; Chaudhary R; Kumar P; Pundir CS
Int J Biol Macromol; 2020 Mar; 146():907-915. PubMed ID: 31726157
[TBL] [Abstract][Full Text] [Related]
13. Amperometric sarcosine biosensor based on hollow magnetic Pt-Fe
Yang Q; Li N; Li Q; Chen S; Wang HL; Yang H
Anal Chim Acta; 2019 Oct; 1078():161-167. PubMed ID: 31358215
[TBL] [Abstract][Full Text] [Related]
14. An amperometric biosensor based on laccase immobilized onto Fe₃O₄NPs/cMWCNT/PANI/Au electrode for determination of phenolic content in tea leaves extract.
Rawal R; Chawla S; Devender ; Pundir CS
Enzyme Microb Technol; 2012 Sep; 51(4):179-85. PubMed ID: 22883551
[TBL] [Abstract][Full Text] [Related]
15. Construction of a triglyceride amperometric biosensor based on chitosan-ZnO nanocomposite film.
Narang J; Pundir CS
Int J Biol Macromol; 2011 Nov; 49(4):707-15. PubMed ID: 21763341
[TBL] [Abstract][Full Text] [Related]
16. An amperometric biosensor based on acetylcholinesterase immobilized onto iron oxide nanoparticles/multi-walled carbon nanotubes modified gold electrode for measurement of organophosphorus insecticides.
Chauhan N; Pundir CS
Anal Chim Acta; 2011 Sep; 701(1):66-74. PubMed ID: 21763810
[TBL] [Abstract][Full Text] [Related]
17. An amperometric glutathione biosensor based on chitosan-iron coated gold nanoparticles modified Pt electrode.
Chauhan N; Narang J; Meena ; Pundir CS
Int J Biol Macromol; 2012 Dec; 51(5):879-86. PubMed ID: 22922113
[TBL] [Abstract][Full Text] [Related]
18. Construction of an uricase nanoparticles modified au electrode for amperometric determination of uric acid.
Chauhan N; Kumar A; Pundir CS
Appl Biochem Biotechnol; 2014 Oct; 174(4):1683-1694. PubMed ID: 25141984
[TBL] [Abstract][Full Text] [Related]
19. Construction of an amperometric TG biosensor based on AuPPy nanocomposite and poly (indole-5-carboxylic acid) modified Au electrode.
Narang J; Chauhan N; Rani P; Pundir CS
Bioprocess Biosyst Eng; 2013 Apr; 36(4):425-32. PubMed ID: 22903594
[TBL] [Abstract][Full Text] [Related]
20. An amperometric biosensor based on laccase immobilized onto MnO2NPs/cMWCNT/PANI modified Au electrode.
Rawal R; Chawla S; Malik P; Pundir CS
Int J Biol Macromol; 2012; 51(1-2):175-81. PubMed ID: 22142791
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]