BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 30255963)

  • 1. Improving apparent diffusion coefficient accuracy on a compact 3T MRI scanner using gradient nonlinearity correction.
    Tao AT; Shu Y; Tan ET; Trzasko JD; Tao S; Reid RD; Weavers PT; Huston J; Bernstein MA
    J Magn Reson Imaging; 2018 Dec; 48(6):1498-1507. PubMed ID: 30255963
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Diffusion-Weighted Imaging of the Abdomen: Correction for Gradient Nonlinearity Bias in Apparent Diffusion Coefficient.
    Wang J; Ma C; Yang P; Wang Z; Chen Y; Bian Y; Shao C; Lu J
    J Magn Reson Imaging; 2023 Jul; 58(1):223-231. PubMed ID: 36373955
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Empirical validation of gradient field models for an accurate ADC measured on clinical 3T MR systems in body oncologic applications.
    Pang Y; Malyarenko DI; Amouzandeh G; Barberi E; Cole M; Vom Endt A; Peeters J; Tan ET; Chenevert TL
    Phys Med; 2021 Jun; 86():113-120. PubMed ID: 34107440
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Distortion-free imaging: A double encoding method (DIADEM) combined with multiband imaging for rapid distortion-free high-resolution diffusion imaging on a compact 3T with high-performance gradients.
    In MH; Tan ET; Trzasko JD; Shu Y; Kang D; Yarach U; Tao S; Gray EM; Huston J; Bernstein MA
    J Magn Reson Imaging; 2020 Jan; 51(1):296-310. PubMed ID: 31111581
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reduced acoustic noise in diffusion tensor imaging on a compact MRI system.
    Tan ET; Hardy CJ; Shu Y; In MH; Guidon A; Huston J; Bernstein MA; K F Foo T
    Magn Reson Med; 2018 Jun; 79(6):2902-2911. PubMed ID: 28971512
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Empirical field mapping for gradient nonlinearity correction of multi-site diffusion weighted MRI.
    Hansen CB; Rogers BP; Schilling KG; Nath V; Blaber JA; Irfanoglu O; Barnett A; Pierpaoli C; Anderson AW; Landman BA
    Magn Reson Imaging; 2021 Feb; 76():69-78. PubMed ID: 33221421
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Solid bone tumors of the spine: Diagnostic performance of apparent diffusion coefficient measured using diffusion-weighted MRI using histology as a reference standard.
    Pozzi G; Albano D; Messina C; Angileri SA; Al-Mnayyis A; Galbusera F; Luzzati A; Perrucchini G; Scotto G; Parafioriti A; Zerbi A; Sconfienza LM
    J Magn Reson Imaging; 2018 Apr; 47(4):1034-1042. PubMed ID: 28755383
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment and quantification of sources of variability in breast apparent diffusion coefficient (ADC) measurements at diffusion weighted imaging.
    Giannotti E; Waugh S; Priba L; Davis Z; Crowe E; Vinnicombe S
    Eur J Radiol; 2015 Sep; 84(9):1729-36. PubMed ID: 26078100
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Apparent Diffusion Coefficient Reproducibility Across 3 T Scanners in a Breast Diffusion Phantom.
    Fang LK; Keenan KE; Carl M; Ojeda-Fournier H; Rodríguez-Soto AE; Rakow-Penner RA
    J Magn Reson Imaging; 2023 Mar; 57(3):812-823. PubMed ID: 36029225
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Time-dependent diffusion MRI to distinguish malignant from benign head and neck tumors.
    Iima M; Yamamoto A; Kataoka M; Yamada Y; Omori K; Feiweier T; Togashi K
    J Magn Reson Imaging; 2019 Jul; 50(1):88-95. PubMed ID: 30578563
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Multisite MRI Intravoxel Incoherent Motion Repeatability and Reproducibility across 3 T Scanners in a Breast Diffusion Phantom: A BReast Intravoxel Incoherent Motion Multisite (BRIMM) Study.
    Basukala D; Mikheev A; Sevilimedu V; Gilani N; Moy L; Pinker K; Thakur SB; Sigmund EE
    J Magn Reson Imaging; 2024 Jun; 59(6):2226-2237. PubMed ID: 37702382
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Diffusion gradient nonlinearity bias correction reduces bias of breast cancer bone metastasis ADC values.
    Buus TW; Jensen AB; Pedersen EM
    J Magn Reson Imaging; 2020 Mar; 51(3):904-911. PubMed ID: 31313407
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Quantitative characterization of carotid plaque components using MR apparent diffusion coefficients and longitudinal relaxation rates at 3T: A comparison with histology.
    Ota H; Tamura H; Itabashi R; Yazawa Y; Nakamura Y; Hisamatsu K; Takamatsu M; Endo H; Niizuma K; Enomoto Y; Nagasaka T; Kajita K; Watanabe M; Yoshimura S; Yuan C
    J Magn Reson Imaging; 2018 Dec; 48(6):1657-1667. PubMed ID: 30325551
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Practical estimate of gradient nonlinearity for implementation of apparent diffusion coefficient bias correction.
    Malkyarenko DI; Chenevert TL
    J Magn Reson Imaging; 2014 Dec; 40(6):1487-95. PubMed ID: 25667948
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Long-Term Stability of Gradient Characteristics Warrants Model-Based Correction of Diffusion Weighting Bias.
    Pang Y; Malyarenko DI; Wilmes LJ; Devaraj A; Tan ET; Marinelli L; Endt AV; Peeters J; Jacobs MA; Newitt DC; Chenevert TL
    Tomography; 2022 Feb; 8(1):364-375. PubMed ID: 35202195
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Repeatability quantification of brain diffusion-weighted imaging for future clinical implementation at a low-field MR-linac.
    Rabe M; Dietrich O; Forbrig R; Niyazi M; Belka C; Corradini S; Landry G; Kurz C
    Radiat Oncol; 2024 Mar; 19(1):31. PubMed ID: 38448888
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improving lymph node characterization in staging malignant lymphoma using first-order ADC texture analysis from whole-body diffusion-weighted MRI.
    De Paepe KN; De Keyzer F; Wolter P; Bechter O; Dierickx D; Janssens A; Verhoef G; Oyen R; Vandecaveye V
    J Magn Reson Imaging; 2018 Oct; 48(4):897-906. PubMed ID: 29656584
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Diffusion-weighted MRI of the lung at 3T evaluated using echo-planar-based and single-shot turbo spin-echo-based acquisition techniques for radiotherapy applications.
    Tyagi N; Cloutier M; Zakian K; Deasy JO; Hunt M; Rimner A
    J Appl Clin Med Phys; 2019 Jan; 20(1):284-292. PubMed ID: 30421496
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Impact of measurement parameters on apparent diffusion coefficient quantification in diffusion-weighted-magnetic resonance imaging.
    Schmidt H; Gatidis S; Schwenzer NF; Martirosian P
    Invest Radiol; 2015 Jan; 50(1):46-56. PubMed ID: 25247326
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Retrospective Correction of ADC for Gradient Nonlinearity Errors in Multicenter Breast DWI Trials: ACRIN6698 Multiplatform Feasibility Study.
    Malyarenko DI; Newitt DC; Amouzandeh G; Wilmes LJ; Tan ET; Marinelli L; Devaraj A; Peeters JM; Giri S; Vom Endt A; Hylton NM; Partridge SC; Chenevert TL
    Tomography; 2020 Jun; 6(2):86-92. PubMed ID: 32548284
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.