766 related articles for article (PubMed ID: 30267166)
1. Performance of two--dimensional ultrasound shear wave elastography: reference values of normal liver stiffness in children.
Galina P; Alexopoulou E; Zellos A; Grigoraki V; Siahanidou T; Kelekis NL; Zarifi M
Pediatr Radiol; 2019 Jan; 49(1):91-98. PubMed ID: 30267166
[TBL] [Abstract][Full Text] [Related]
2. Normal values of liver shear wave velocity in healthy children assessed by acoustic radiation force impulse imaging using a convex probe and a linear probe.
Fontanilla T; Cañas T; Macia A; Alfageme M; Gutierrez Junquera C; Malalana A; Luz Cilleruelo M; Roman E; Miralles M
Ultrasound Med Biol; 2014 Mar; 40(3):470-7. PubMed ID: 24361222
[TBL] [Abstract][Full Text] [Related]
3. Ultrasound Shear Wave Elastography for Liver Disease. A Critical Appraisal of the Many Actors on the Stage.
Piscaglia F; Salvatore V; Mulazzani L; Cantisani V; Schiavone C
Ultraschall Med; 2016 Feb; 37(1):1-5. PubMed ID: 26871407
[TBL] [Abstract][Full Text] [Related]
4. Normal liver stiffness in healthy adults assessed by real-time shear wave elastography and factors that influence this method.
Huang Z; Zheng J; Zeng J; Wang X; Wu T; Zheng R
Ultrasound Med Biol; 2014 Nov; 40(11):2549-55. PubMed ID: 25282481
[TBL] [Abstract][Full Text] [Related]
5. Transcranial Shear Wave Elastography of Neonatal and Infant Brains for Quantitative Evaluation of Increased Intracranial Pressure.
Dirrichs T; Meiser N; Panek A; Trepels-Kottek S; Orlikowsky T; Kuhl CK; Schrading S
Invest Radiol; 2019 Nov; 54(11):719-727. PubMed ID: 31464808
[TBL] [Abstract][Full Text] [Related]
6. Shear-wave elastography of the liver in a healthy pediatric population.
Yang H; Sun Y; Tang Y; Lu Y; Hu B; Ying T
J Clin Ultrasound; 2020 Mar; 48(3):139-144. PubMed ID: 31846085
[TBL] [Abstract][Full Text] [Related]
7. Feasibility and Diagnostic Accuracy of Supersonic Shear-Wave Elastography for the Assessment of Liver Stiffness and Liver Fibrosis in Children: A Pilot Study of 96 Patients.
Franchi-Abella S; Corno L; Gonzales E; Antoni G; Fabre M; Ducot B; Pariente D; Gennisson JL; Tanter M; Corréas JM
Radiology; 2016 Feb; 278(2):554-62. PubMed ID: 26305193
[TBL] [Abstract][Full Text] [Related]
8. Reference values of normal liver stiffness in healthy children by two methods: 2D shear wave and transient elastography.
Mărginean CO; Meliţ LE; Ghiga DV; Săsăran MO
Sci Rep; 2020 Apr; 10(1):7213. PubMed ID: 32350349
[TBL] [Abstract][Full Text] [Related]
9. Quantitative Assessment of Thyroid Glands in Healthy Children With Shear Wave Elastography.
Uysal E; Öztürk M
Ultrasound Q; 2019 Sep; 35(3):297-300. PubMed ID: 30724864
[TBL] [Abstract][Full Text] [Related]
10. Normative values of pancreas stiffness by shear wave elastography in healthy children and adolescents.
Ozturk M; Çalışkan E; Bayramoglu Z; Adaletli I
J Med Ultrason (2001); 2020 Oct; 47(4):583-589. PubMed ID: 32676807
[TBL] [Abstract][Full Text] [Related]
11. Diagnostic performance of quantitative shear wave elastography in the evaluation of solid breast masses: determination of the most discriminatory parameter.
Au FW; Ghai S; Moshonov H; Kahn H; Brennan C; Dua H; Crystal P
AJR Am J Roentgenol; 2014 Sep; 203(3):W328-36. PubMed ID: 25148191
[TBL] [Abstract][Full Text] [Related]
12. Liver Stiffness Measured by 2-Dimensional Shear Wave Elastography: Prospective Evaluation of Healthy Volunteers and Patients With Liver Cirrhosis.
Petzold G; Hofer J; Ellenrieder V; Neesse A; Kunsch S
J Ultrasound Med; 2019 Jul; 38(7):1769-1777. PubMed ID: 30536601
[TBL] [Abstract][Full Text] [Related]
13. Normal Liver Stiffness Values in Children: A Comparison of Three Different Elastography Methods.
Mjelle AB; Mulabecirovic A; Havre RF; Rosendahl K; Juliusson PB; Olafsdottir E; Gilja OH; Vesterhus M
J Pediatr Gastroenterol Nutr; 2019 May; 68(5):706-712. PubMed ID: 30889132
[TBL] [Abstract][Full Text] [Related]
14. Liver Stiffness Values Are Lower in Pediatric Subjects than in Adults and Increase with Age: A Multifrequency MR Elastography Study.
Etchell E; Jugé L; Hatt A; Sinkus R; Bilston LE
Radiology; 2017 Apr; 283(1):222-230. PubMed ID: 27755913
[TBL] [Abstract][Full Text] [Related]
15. Nondiseased liver stiffness measured by shear wave elastography: a pilot study.
Cha SW; Jeong WK; Kim Y; Kim MY; Kim J; Kim SY; Ryu JA; Kim TY; Sohn JH; Kim YH
J Ultrasound Med; 2014 Jan; 33(1):53-60. PubMed ID: 24371099
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of Liver, Kidney, and Spleen Elasticity in Healthy Newborns and Infants Using Shear Wave Elastography.
Palabiyik FB; Inci E; Turkay R; Bas D
J Ultrasound Med; 2017 Oct; 36(10):2039-2045. PubMed ID: 28417472
[TBL] [Abstract][Full Text] [Related]
17. Normative values of thymus in healthy children; stiffness by shear wave elastography.
Bayramoğlu Z; Öztürk M; Çalışkan E; Ayyıldız H; Adaletli İ
Diagn Interv Radiol; 2020 Mar; 26(2):147-152. PubMed ID: 32116221
[TBL] [Abstract][Full Text] [Related]
18. Shear wave elastography parameters of normal soft tissues of the neck.
Herman J; Sedlackova Z; Vachutka J; Furst T; Salzman R; Vomacka J
Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub; 2017 Sep; 161(3):320-325. PubMed ID: 28546639
[TBL] [Abstract][Full Text] [Related]
19. Quantification of kidney fibrosis using ultrasonic shear wave elastography: experimental study with a rabbit model.
Moon SK; Kim SY; Cho JY; Kim SH
J Ultrasound Med; 2015 May; 34(5):869-77. PubMed ID: 25911705
[TBL] [Abstract][Full Text] [Related]
20. Determination of Normal Skin Elasticity by Using Real-time Shear Wave Elastography.
Yang Y; Wang L; Yan F; Xiang X; Tang Y; Zhang L; Liu J; Qiu L
J Ultrasound Med; 2018 Nov; 37(11):2507-2516. PubMed ID: 29575120
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]