1166 related articles for article (PubMed ID: 30269967)
1. Same survival but higher rate of osteolysis for metal-on-metal Ultamet versus ceramic-on-ceramic in patients undergoing primary total hip arthroplasty after 8 years of follow-up.
Higuchi Y; Seki T; Takegami Y; Komatsu D; Morita D; Ishiguro N
Orthop Traumatol Surg Res; 2018 Dec; 104(8):1155-1161. PubMed ID: 30269967
[TBL] [Abstract][Full Text] [Related]
2. Comparison of cementless total hip arthroplasty survivorship between metal-on-highly cross-linked polyethylene and ceramic on ceramic bearings: A case control study with a 5-9-year follow-up.
Higuchi Y; Seki T; Hasegawa Y; Morita D; Komatsu D; Takegami Y; Ishiguro N
Orthop Traumatol Surg Res; 2018 Sep; 104(5):663-669. PubMed ID: 29902637
[TBL] [Abstract][Full Text] [Related]
3. Do the Reasons for Ceramic-on-ceramic Revisions Differ From Other Bearings in Total Hip Arthroplasty?
Migaud H; Putman S; Kern G; Isida R; Girard J; Ramdane N; Delaunay CP; Hamadouche M;
Clin Orthop Relat Res; 2016 Oct; 474(10):2190-9. PubMed ID: 27255729
[TBL] [Abstract][Full Text] [Related]
4. Periprosthetic Joint Infection in Hip Arthroplasty: Is There an Association Between Infection and Bearing Surface Type?
Pitto RP; Sedel L
Clin Orthop Relat Res; 2016 Oct; 474(10):2213-8. PubMed ID: 27249955
[TBL] [Abstract][Full Text] [Related]
5. Outcomes of different bearings in total hip arthroplasty - implant survival, revision causes, and patient-reported outcome.
Varnum C
Dan Med J; 2017 Mar; 64(3):. PubMed ID: 28260601
[TBL] [Abstract][Full Text] [Related]
6. What Is the Frequency of Fracture of Ceramic Components in THA? Results from the Norwegian Arthroplasty Register from 1997 to 2017.
Hallan G; Fenstad AM; Furnes O
Clin Orthop Relat Res; 2020 Jun; 478(6):1254-1261. PubMed ID: 32348085
[TBL] [Abstract][Full Text] [Related]
7. Ceramic-on-ceramic THA Implants in Patients Younger Than 20 Years.
Hannouche D; Devriese F; Delambre J; Zadegan F; Tourabaly I; Sedel L; Chevret S; Nizard R
Clin Orthop Relat Res; 2016 Feb; 474(2):520-7. PubMed ID: 26341897
[TBL] [Abstract][Full Text] [Related]
8. Primary ceramic-on-ceramic total hip arthroplasty using a 32-mm ceramic head with a titanium-alloy sleeve.
Lim SJ; Jang SP; Kim DW; Moon YW; Park YS
Clin Orthop Relat Res; 2015 Dec; 473(12):3781-7. PubMed ID: 26024582
[TBL] [Abstract][Full Text] [Related]
9. Significantly Lower Wear of Ceramic-on-Ceramic Bearings Than Metal-on-Highly Cross-Linked Polyethylene Bearings: A 10- to 14-Year Follow-Up Study.
Higuchi Y; Hasegawa Y; Seki T; Komatsu D; Ishiguro N
J Arthroplasty; 2016 Jun; 31(6):1246-1250. PubMed ID: 26781388
[TBL] [Abstract][Full Text] [Related]
10. Comparison of ten-year survivorship of hip prostheses with use of conventional polyethylene, metal-on-metal, or ceramic-on-ceramic bearings.
Milošev I; Kovač S; Trebše R; Levašič V; Pišot V
J Bone Joint Surg Am; 2012 Oct; 94(19):1756-63. PubMed ID: 23032586
[TBL] [Abstract][Full Text] [Related]
11. Are ceramic-on-ceramic bearings in total hip arthroplasty associated with reduced revision risk for late dislocation?
Pitto RP; Garland M; Sedel L
Clin Orthop Relat Res; 2015 Dec; 473(12):3790-5. PubMed ID: 26070775
[TBL] [Abstract][Full Text] [Related]
12. Long-Term Outcomes After Metal-on-Metal Total Hip Arthroplasty With a 28-mm Head: A 17- to 23-Year Follow-Up Study of a Previous Report.
Moon JK; Kim Y; Hwang KT; Yang JH; Oh YH; Kim YH
J Arthroplasty; 2018 Jul; 33(7):2165-2172. PubMed ID: 29656971
[TBL] [Abstract][Full Text] [Related]
13. Catastrophic failure of femoral stem modular junction when combined with metal-on-metal bearing in comparison to ceramic-on-ceramic: A retrospective cohort study.
Beauchamp JE; Vendittoli PA; Barry J; Pelet S; Belzile EL
Orthop Traumatol Surg Res; 2021 Feb; 107(1):102749. PubMed ID: 33316446
[TBL] [Abstract][Full Text] [Related]
14. Comparison of Postoperative Complications Following Metal-on-Metal Total Hip Arthroplasty With Other Hip Bearings in Medicare Population.
Kleeman LT; Bala A; Penrose CT; Seyler TM; Wellman SS; Bolognesi MP
J Arthroplasty; 2018 Jun; 33(6):1826-1832. PubMed ID: 29510952
[TBL] [Abstract][Full Text] [Related]
15. High Risk of Neck-liner Impingement and Notching Observed with Thick Femoral Neck Implants in Ceramic-on-ceramic THA.
Kim HS; Park JW; Lee SJ; Lee YK; Ha YC; Koo KH
Clin Orthop Relat Res; 2022 Apr; 480(4):690-699. PubMed ID: 34699410
[TBL] [Abstract][Full Text] [Related]
16. Cementless Total Hip Arthroplasty With Metasul Bearings Provides Good Results in Active Young Patients: A Concise Followup.
Delaunay CP; Putman S; Puliéro B; Bégin M; Migaud H; Bonnomet F
Clin Orthop Relat Res; 2016 Oct; 474(10):2126-33. PubMed ID: 27278679
[TBL] [Abstract][Full Text] [Related]
17. Ceramic-on-ceramic total hip arthroplasty is superior to metal-on-conventional polyethylene at 20-year follow-up: A randomised clinical trial.
Vendittoli PA; Shahin M; Rivière C; Barry J; Lavoie P; Duval N
Orthop Traumatol Surg Res; 2021 Feb; 107(1):102744. PubMed ID: 33316444
[TBL] [Abstract][Full Text] [Related]
18. Metal on Metal or Ceramic on Ceramic for Cementless Total Hip Arthroplasty: A Meta-Analysis.
Lee YK; Yoon BH; Choi YS; Jo WL; Ha YC; Koo KH
J Arthroplasty; 2016 Nov; 31(11):2637-2645.e1. PubMed ID: 27215192
[TBL] [Abstract][Full Text] [Related]
19. Do alumina matrix composite bearings decrease hip noises and bearing fractures at a minimum of 5 years after THA?
Baek SH; Kim WK; Kim JY; Kim SY
Clin Orthop Relat Res; 2015 Dec; 473(12):3796-802. PubMed ID: 26126991
[TBL] [Abstract][Full Text] [Related]
20. Ceramic-on-ceramic THA associated with fewer dislocations and less muscle degeneration by preserving muscle progenitors.
Hernigou P; Roussignol X; Delambre J; Poignard A; Flouzat-Lachaniette CH
Clin Orthop Relat Res; 2015 Dec; 473(12):3762-9. PubMed ID: 26054482
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]