These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
23. Comparison of 22-gauge standard fine needle versus core biopsy needle for endoscopic ultrasound-guided sampling of suspected pancreatic cancer: a randomized crossover trial. Noh DH; Choi K; Gu S; Cho J; Jang KT; Woo YS; Lee KT; Lee JK; Lee KH Scand J Gastroenterol; 2018 Jan; 53(1):94-99. PubMed ID: 29065734 [TBL] [Abstract][Full Text] [Related]
24. Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles. Yang MJ; Yim H; Hwang JC; Lee D; Kim YB; Lim SG; Kim SS; Kang JK; Yoo BM; Kim JH BMC Gastroenterol; 2015 Sep; 15():122. PubMed ID: 26419845 [TBL] [Abstract][Full Text] [Related]
25. The efficacy and safety of single-session endoscopic ultrasound-guided fine needle aspiration and endoscopic retrograde cholangiopancreatography for evaluation of pancreatic masses. Noma Y; Kawamoto H; Kato H; Iwamuro M; Hirao K; Fujii M; Tsutsumi K; Horiguchi S; Yamamoto N; Sakakihara I; Tomoda T; Matsumoto K; Okada H; Yamamoto K Hepatogastroenterology; 2014 Sep; 61(134):1775-9. PubMed ID: 25436378 [TBL] [Abstract][Full Text] [Related]
26. Endoscopic ultrasound-guided fine needle aspiration in the differentiation of type 1 and type 2 autoimmune pancreatitis. Ishikawa T; Itoh A; Kawashima H; Ohno E; Matsubara H; Itoh Y; Nakamura Y; Hiramatsu T; Nakamura M; Miyahara R; Ohmiya N; Goto H; Hirooka Y World J Gastroenterol; 2012 Aug; 18(29):3883-8. PubMed ID: 22876041 [TBL] [Abstract][Full Text] [Related]
27. Comparison of endoscopic retrograde cholangiopancreatography with papillary biopsy and endoscopic ultrasound-guided pancreatic biopsy in the diagnosis of autoimmune pancreatitis. Jung JG; Lee JK; Lee KH; Lee KT; Woo YS; Paik WH; Park DH; Lee SS; Seo DW; Lee SK; Kim MH Pancreatology; 2015; 15(3):259-64. PubMed ID: 25891790 [TBL] [Abstract][Full Text] [Related]
28. Increasing Number of Passes Beyond 4 Does Not Increase Sensitivity of Detection of Pancreatic Malignancy by Endoscopic Ultrasound-Guided Fine-Needle Aspiration. Mohamadnejad M; Mullady D; Early DS; Collins B; Marshall C; Sams S; Yen R; Rizeq M; Romanas M; Nawaz S; Ulusarac O; Hollander T; Wilson RH; Simon VC; Kushnir V; Amateau SK; Brauer BC; Gaddam S; Azar RR; Komanduri S; Shah R; Das A; Edmundowicz S; Muthusamy VR; Rastogi A; Wani S Clin Gastroenterol Hepatol; 2017 Jul; 15(7):1071-1078.e2. PubMed ID: 28025154 [TBL] [Abstract][Full Text] [Related]
29. Comparison of endoscopic ultrasound-guided fine needle aspiration for focal pancreatic lesions in patients with normal parenchyma and chronic pancreatitis. Fritscher-Ravens A; Brand L; Knöfel WT; Bobrowski C; Topalidis T; Thonke F; de Werth A; Soehendra N Am J Gastroenterol; 2002 Nov; 97(11):2768-75. PubMed ID: 12425546 [TBL] [Abstract][Full Text] [Related]
30. Endoscopic ultrasound core needle for diagnosing of solid pancreatic lesions: is rapid on-site evaluation really necessary? Arena M; Eusebi LH; Pellicano R; Palamara MA; Iabichino G; Consolo P; Fagoonee S; Opocher E; Barabino M; Luigiano C Minerva Med; 2017 Dec; 108(6):547-553. PubMed ID: 28750500 [TBL] [Abstract][Full Text] [Related]
31. Pancreatic endoscopic ultrasound-guided fine needle aspiration: complication rate and clinical course in a single centre. Carrara S; Arcidiacono PG; Mezzi G; Petrone MC; Boemo C; Testoni PA Dig Liver Dis; 2010 Jul; 42(7):520-3. PubMed ID: 19955025 [TBL] [Abstract][Full Text] [Related]
32. Benefit of high negative pressure during endoscopic ultrasound-guided fine-needle aspiration with standard 22-gauge needles for pancreatic lesions: a retrospective comparative study. Sato J; Ishiwatari H; Sasaki K; Fujie S; Kaneko J; Satoh T; Matsubayashi H; Kishida Y; Yoshida M; Ito S; Kawata N; Imai K; Kakushima N; Takizawa K; Hotta K; Ono H Scand J Gastroenterol; 2019 Jan; 54(1):108-113. PubMed ID: 30676114 [TBL] [Abstract][Full Text] [Related]
33. Rapid on-site evaluation for endoscopic ultrasound-guided fine-needle biopsy of the pancreas decreases the incidence of repeat biopsy procedures. Collins BT; Murad FM; Wang JF; Bernadt CT Cancer Cytopathol; 2013 Sep; 121(9):518-24. PubMed ID: 23983161 [TBL] [Abstract][Full Text] [Related]
34. Endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNA) in insulinomas: Indications and clinical relevance in a single investigator cohort of 47 patients. Kann PH; Moll R; Bartsch D; Pfützner A; Forst T; Tamagno G; Goebel JN; Fourkiotis V; Bergmann SR; Collienne M Endocrine; 2017 Apr; 56(1):158-163. PubMed ID: 27905047 [TBL] [Abstract][Full Text] [Related]
35. Biliary plastic stent does not influence the accuracy of endoscopic ultrasound-guided sampling of pancreatic head masses performed with core biopsy needles. Antonini F; Fuccio L; Giorgini S; Fabbri C; Frazzoni L; Scarpelli M; Macarri G Dig Liver Dis; 2017 Aug; 49(8):898-902. PubMed ID: 28465092 [TBL] [Abstract][Full Text] [Related]
36. Prospective multicenter study on the usefulness of EUS-guided FNA biopsy for the diagnosis of autoimmune pancreatitis. Morishima T; Kawashima H; Ohno E; Yamamura T; Funasaka K; Nakamura M; Miyahara R; Watanabe O; Ishigami M; Shimoyama Y; Nakamura S; Hashimoto S; Goto H; Hirooka Y Gastrointest Endosc; 2016 Aug; 84(2):241-8. PubMed ID: 26777565 [TBL] [Abstract][Full Text] [Related]
37. Risk of gastric or peritoneal recurrence, and long-term outcomes, following pancreatic cancer resection with preoperative endosonographically guided fine needle aspiration. Ngamruengphong S; Xu C; Woodward TA; Raimondo M; Stauffer JA; Asbun HJ; Wallace MB Endoscopy; 2013 Aug; 45(8):619-26. PubMed ID: 23881804 [TBL] [Abstract][Full Text] [Related]
38. Comparing endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) versus fine needle biopsy (FNB) in the diagnosis of solid lesions: study protocol for a randomized controlled trial. Wang J; Wu X; Yin P; Guo Q; Hou W; Li Y; Wang Y; Cheng B Trials; 2016 Apr; 17():198. PubMed ID: 27071386 [TBL] [Abstract][Full Text] [Related]
39. Core biopsy needle versus standard aspiration needle for endoscopic ultrasound-guided sampling of solid pancreatic masses: a randomized parallel-group study. Lee YN; Moon JH; Kim HK; Choi HJ; Choi MH; Kim DC; Lee TH; Cha SW; Cho YD; Park SH Endoscopy; 2014 Dec; 46(12):1056-62. PubMed ID: 25098611 [TBL] [Abstract][Full Text] [Related]
40. Effectiveness of combined endoscopic ultrasound-guided fine-needle aspiration biopsy and stenting in patients with suspected pancreatic cancer. Camus M; Trouilloud I; Villacis AL; Mangialavori L; Duchmann JC; Gaudric M; Roseau G; Terris B; Mitry E; Chaussade S; Prat F Eur J Gastroenterol Hepatol; 2012 Nov; 24(11):1281-7. PubMed ID: 22890210 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]