These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
195 related articles for article (PubMed ID: 30271371)
1. Thigh-Derived Inertial Sensor Metrics to Assess the Sit-to-Stand and Stand-to-Sit Transitions in the Timed Up and Go (TUG) Task for Quantifying Mobility Impairment in Multiple Sclerosis. Witchel HJ; Oberndorfer C; Needham R; Healy A; Westling CEI; Guppy JH; Bush J; Barth J; Herberz C; Roggen D; Eskofier BM; Rashid W; Chockalingam N; Klucken J Front Neurol; 2018; 9():684. PubMed ID: 30271371 [No Abstract] [Full Text] [Related]
2. Metrics extracted from a single wearable sensor during sit-stand transitions relate to mobility impairment and fall risk in people with multiple sclerosis. Tulipani LJ; Meyer B; Larie D; Solomon AJ; McGinnis RS Gait Posture; 2020 Jul; 80():361-366. PubMed ID: 32615409 [TBL] [Abstract][Full Text] [Related]
3. Differences in Trunk Accelerometry Between Frail and Nonfrail Elderly Persons in Sit-to-Stand and Stand-to-Sit Transitions Based on a Mobile Inertial Sensor. Galán-Mercant A; Cuesta-Vargas AI JMIR Mhealth Uhealth; 2013 Aug; 1(2):e21. PubMed ID: 25098977 [TBL] [Abstract][Full Text] [Related]
4. Use of an instrumented dual-task timed up and go test in children with traumatic brain injury. Newman MA; Hirsch MA; Peindl RD; Habet NA; Tsai TJ; Runyon MS; Huynh T; Phillips C; Zheng N; Gait Posture; 2020 Feb; 76():193-197. PubMed ID: 31862669 [TBL] [Abstract][Full Text] [Related]
5. Instrumented balance and walking assessments in persons with multiple sclerosis show strong test-retest reliability. Craig JJ; Bruetsch AP; Lynch SG; Horak FB; Huisinga JM J Neuroeng Rehabil; 2017 May; 14(1):43. PubMed ID: 28532417 [TBL] [Abstract][Full Text] [Related]
6. The timed up & go test sit-to-stand transition: Which signals measured by inertial sensors are a viable route for continuous analysis? Neťuková S; Klempíř O; Krupička R; Dušek P; Kutílek P; Szabó Z; Růžička E Gait Posture; 2021 Feb; 84():8-10. PubMed ID: 33260079 [TBL] [Abstract][Full Text] [Related]
7. The Sit-to-Stand Transition as a Biomarker for Impairment: Comparison of Instrumented 30-Second Chair Stand Test and Daily Life Transitions in Multiple Sclerosis. Tulipani LJ; Meyer B; Fox S; Solomon AJ; Mcginnis RS IEEE Trans Neural Syst Rehabil Eng; 2022; 30():1213-1222. PubMed ID: 35468063 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of an inertial sensor system for analysis of timed-up-and-go under dual-task demands. Coulthard JT; Treen TT; Oates AR; Lanovaz JL Gait Posture; 2015 May; 41(4):882-7. PubMed ID: 25827680 [TBL] [Abstract][Full Text] [Related]
9. Convergent Validity of a Wearable Sensor System for Measuring Sub-Task Performance during the Timed Up-and-Go Test. Beyea J; McGibbon CA; Sexton A; Noble J; O'Connell C Sensors (Basel); 2017 Apr; 17(4):. PubMed ID: 28441748 [TBL] [Abstract][Full Text] [Related]
10. Quantifying sit-to-stand and stand-to-sit transitions in free-living environments using the activPAL thigh-worn activity monitor. Pickford CG; Findlow AH; Kerr A; Banger M; Clarke-Cornwell AM; Hollands KL; Quinn T; Granat MH Gait Posture; 2019 Sep; 73():140-146. PubMed ID: 31325738 [TBL] [Abstract][Full Text] [Related]
11. Transition Between the Timed up and Go Turn to Sit Subtasks: Is Timing Everything? Weiss A; Mirelman A; Giladi N; Barnes LL; Bennett DA; Buchman AS; Hausdorff JM J Am Med Dir Assoc; 2016 Sep; 17(9):864.e9-864.e15. PubMed ID: 27569715 [TBL] [Abstract][Full Text] [Related]
12. The contribution of the instrumented Timed-Up-and-Go test to detect falls and fear of falling in people with multiple sclerosis. Hershkovitz L; Malcay O; Grinberg Y; Berkowitz S; Kalron A Mult Scler Relat Disord; 2019 Jan; 27():226-231. PubMed ID: 30415024 [TBL] [Abstract][Full Text] [Related]
13. Reliability of the sub-components of the instrumented timed up and go test in ambulatory children with traumatic brain injury and typically developed controls. Newman MA; Hirsch MA; Peindl RD; Habet NA; Tsai TJ; Runyon MS; Huynh T; Zheng N; Gait Posture; 2018 Jun; 63():248-253. PubMed ID: 29778065 [TBL] [Abstract][Full Text] [Related]
14. Timed Up and Go in men and women with Multiple Sclerosis: Effect of muscular strength. Pau M; Casu G; Porta M; Pilloni G; Frau J; Coghe G; Cocco E J Bodyw Mov Ther; 2020 Oct; 24(4):124-130. PubMed ID: 33218499 [TBL] [Abstract][Full Text] [Related]
15. Multi-parametric evaluation of sit-to-stand and stand-to-sit transitions in elderly people. Ganea R; Paraschiv-Ionescu A; Büla C; Rochat S; Aminian K Med Eng Phys; 2011 Nov; 33(9):1086-93. PubMed ID: 21601505 [TBL] [Abstract][Full Text] [Related]
16. Auto detection and segmentation of physical activities during a Timed-Up-and-Go (TUG) task in healthy older adults using multiple inertial sensors. Nguyen HP; Ayachi F; Lavigne-Pelletier C; Blamoutier M; Rahimi F; Boissy P; Jog M; Duval C J Neuroeng Rehabil; 2015 Apr; 12():36. PubMed ID: 25885438 [TBL] [Abstract][Full Text] [Related]
17. Are static and functional balance abilities related in individuals with Multiple Sclerosis? Pau M; Porta M; Coghe G; Corona F; Pilloni G; Lorefice L; Marrosu MG; Cocco E Mult Scler Relat Disord; 2017 Jul; 15():1-6. PubMed ID: 28641764 [TBL] [Abstract][Full Text] [Related]
18. Biomechanical analysis of the timed up-and-go (TUG) test in children with and without Down syndrome. Beerse M; Lelko M; Wu J Gait Posture; 2019 Feb; 68():409-414. PubMed ID: 30594868 [TBL] [Abstract][Full Text] [Related]
19. Evaluation of Lower-Limb Kinematics during Timed Up and Go (TUG) Test in Subjects with Locomotive Syndrome (LS) Using Wearable Gait Sensors (H-Gait System). Kataoka Y; Saito Y; Takeda R; Ishida T; Tadano S; Suzuki T; Nakamura K; Nakata A; Osuka S; Yamada S; Samukawa M; Tohyama H Sensors (Basel); 2023 Jan; 23(2):. PubMed ID: 36679484 [TBL] [Abstract][Full Text] [Related]