These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 30273807)

  • 1. A vibration analysis of a cracked micro-cantilever in an atomic force microscope by using transfer matrix method.
    Dastjerdi S; Abbasi M
    Ultramicroscopy; 2019 Jan; 196():33-39. PubMed ID: 30273807
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dynamic response of a cracked atomic force microscope cantilever used for nanomachining.
    Lee HL; Chang WJ
    Nanoscale Res Lett; 2012 Feb; 7(1):131. PubMed ID: 22335820
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Coupled lateral bending-torsional vibration sensitivity of atomic force microscope cantilever.
    Lee HL; Chang WJ
    Ultramicroscopy; 2008 Jul; 108(8):707-11. PubMed ID: 18054438
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sensitivity of flexural vibration mode of the rectangular atomic force microscope micro cantilevers in liquid to the surface stiffness variations.
    Farokh Payam A
    Ultramicroscopy; 2013 Dec; 135():84-8. PubMed ID: 23942312
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Study of the sensitivity and resonant frequency of the torsional modes of an AFM cantilever with a sidewall probe based on a nonlocal elasticity theory.
    Abbasi M; Karami Mohammadi A
    Microsc Res Tech; 2015 May; 78(5):408-15. PubMed ID: 25755027
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Characterizing the free and surface-coupled vibrations of heated-tip atomic force microscope cantilevers.
    Killgore JP; Tung RC; Hurley DC
    Nanotechnology; 2014 Aug; 25(34):345701. PubMed ID: 25098183
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Study of the sensitivity of the first four flexural modes of an AFM cantilever with a sidewall probe.
    Chang WJ; Lee HL; Chen TY
    Ultramicroscopy; 2008 Jun; 108(7):619-24. PubMed ID: 18037563
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of anisotropic material property on the spring constant and the resonant frequency of atomic force microscope cantilever.
    Yeh MK; Tai NH; Chen BY
    Rev Sci Instrum; 2009 Apr; 80(4):043705. PubMed ID: 19405664
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Suppression of spurious vibration of cantilever in atomic force microscopy by enhancement of bending rigidity of cantilever chip substrate.
    Tsuji T; Kobari K; Ide S; Yamanaka K
    Rev Sci Instrum; 2007 Oct; 78(10):103703. PubMed ID: 17979424
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A simulation of atomic force microscope microcantilever in the tapping mode utilizing couple stress theory.
    Abbasi M
    Micron; 2018 Apr; 107():20-27. PubMed ID: 29414132
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Atomic force microscope cantilever spring constant evaluation for higher mode oscillations: a kinetostatic method.
    Tseytlin YM
    Rev Sci Instrum; 2008 Feb; 79(2 Pt 1):025102. PubMed ID: 18315324
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dynamic analysis of flexural vibration mode of an atomic force microscope cantilever with a sidewall probe in liquid.
    Payam AF; Duy Vy N
    Microsc Res Tech; 2021 Apr; 84(4):782-788. PubMed ID: 33155739
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of tip mass on frequency response and sensitivity of AFM cantilever in liquid.
    Farokh Payam A; Fathipour M
    Micron; 2015 Mar; 70():50-4. PubMed ID: 25562584
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A new model for investigating the flexural vibration of an atomic force microscope cantilever.
    Abbasi M; Karami Mohammadi A
    Ultramicroscopy; 2010 Oct; 110(11):1374-9. PubMed ID: 20702041
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Modelling oscillatory flexure modes of an atomic force microscope cantilever in contact mode whilst imaging at high speed.
    Payton OD; Picco L; Miles MJ; Homer ME; Champneys AR
    Nanotechnology; 2012 Jul; 23(26):265702. PubMed ID: 22699489
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Resonant frequency and sensitivity of a caliper formed with assembled cantilever probes based on the modified strain gradient theory.
    Abbasi M; Afkhami SE
    Microsc Microanal; 2014 Dec; 20(6):1672-81. PubMed ID: 25205330
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Resonance frequencies of AFM cantilevers in contact with a surface.
    Verbiest GJ; Rost MJ
    Ultramicroscopy; 2016 Dec; 171():70-76. PubMed ID: 27615394
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Finite-element vibration analysis of tapping-mode atomic force microscopy in liquid.
    Song Y; Bhushan B
    Ultramicroscopy; 2007 Oct; 107(10-11):1095-104. PubMed ID: 17566661
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Topography imaging with a heated atomic force microscope cantilever in tapping mode.
    Park K; Lee J; Zhang ZM; King WP
    Rev Sci Instrum; 2007 Apr; 78(4):043709. PubMed ID: 17477672
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Novel Method to Reconstruct the Force Curve by Higher Harmonics of the First Two Flexural Modes in Frequency Modulation Atomic Force Microscope (FM-AFM).
    Zhang S; Qian J; Li Y; Zhang Y; Wang Z
    Microsc Microanal; 2018 Jun; 24(3):256-263. PubMed ID: 29860955
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.